OWNERS MANUAL FOR TWO-ST AGE AIR COMPRESSOR Model No. LM7580V2C Model No. Horsepower Voltage/Hertz/Phase Minimum Branch Circuit Requirement *Fuse Type Air Tank Capacity Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM @ 175 PSIG Magnetic Starter LM7580V2C 7.
2—ENG T ABLE OF CONTENTS Page Page SAFETY GUIDELINES .................................. 2 WARNING CHART ........................................ 3 - 4 SPECIFICATIONS ......................................... 5 GLOSSARY ..............................
3—ENG RISK OF BURSTING RISK OF EXPLOSION OR FIRE AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION: 1. FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK, CAUSING RUST AND THINNING OF THE STEEL TANK.
4—ENG HAZARD RISK OF ELECTRICAL SHOCK RISK FROM FLYING OBJECTS RISK TO BREATHING RISK FROM MOVING PARTS RISK OF BURNS WHAT CAN HAPPEN YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY. LIKE ANY OTHER ELECTRI- CALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK.
5—ENG Refer to cover page for the specifications of your compressor. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the compressor is connected to a circuit protected by fuses, use dual element time delay fuses, as noted in specification chart.
6—ENG GENERAL INFORMA TION You have purchased a complete compressor outfit consisting of an air compressor, air tank, electric motor, and associated controls and instruments. The outfit you have selected is a stationary model and contains a two stage air compressor pump.
7—ENG DESCRIPTION OF OPERA TION to restart freely. When the motor stops running, air will be heard escaping from the valve for a few seconds. No air should be heard leaking when the motor is running.
8—ENG INST ALLA TION AND BREAK-IN PROCEDURES This compressor should be permanently mounted in place on a level floor. Operate the air compressor in a clean, dry and well ventilated area. The air intake filter must be kept clear of obstructions which could reduce air delivery of the air compressor.
9—ENG INST ALLA TION AND BREAK-IN PROCEDURES Wiring Instructions If your compressor unit is not equipped with a plug-in type power cord, perform electrical wiring according to the following instructions: IMPROPER ELECTRICAL GROUNDING CAN RESULT IN A RISK OF ELECTRICAL SHOCK.
10—ENG INST ALLA TION AND BREAK-IN PROCEDURES Break-In Procedures Additional Regulators and Controls Multi-viscosity motor oils like 10W30, should not be used in an air compressor. They leave carbon deposits on critical compo- nents, thus reducing performance and com- pressor life.
11—ENG INST ALLA TION AND BREAK-IN PROCEDURES Piping Note For underground installation, bury air lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before un- derground lines are covered to make sure all pipe joints are free from leaks.
12—ENG OPERA TING PROCEDURES 1. Before attaching an air hose or accessory, make sure the outlet valve is in the closed position. On units equipped with a pressure switch lever make sure the switch is in the OFF position. Compressed air from the outfit may contain water condensation and oil mist.
13—ENG MAINTENANCE UNIT CYCLES AUTOMATICALLY WHEN POWER IS ON. DURING MAINTENANCE, YOU COULD BE EXPOSED TO VOLTAGE SOURCES, COMPRESSED AIR OR MOVING PARTS. PERSONAL INJURIES CAN OCCUR. DISCONNECT POWER SOURCE AND BLEED OFF ALL AIR TANK PRESSURE BEFORE DOING ANY MAINTENANCE OR REPAIR.
14—ENG SERVICE INSTRUCTIONS A dirty air filter will not allow the compressor to operate at full capacity. Before you use the compressor, check the air filter to be sure it is clean. If it is dirty, replace it with a new filter. Air Filter - Inspection and Replacement NOTE Keep the air filter clean at all times.
15—ENG SERVICE INSTRUCTIONS 6. Check that the valve disc moves freely and that the spring holds the disc in the upper, closed position. The check valve may be cleaned with a solvent. 7. Apply sealant to the check valve threads. Reinstall the check valve.
16—ENG SERVICE INSTRUCTIONS Adjusting Belt T ension Adjust belt tension as described below. For compressors with a motor slide mount, adjust belt tension as follows: 1. Slide motor away from compressor until desired tension is obtained. On two stage compressors, the belt should deflect 1/2" at midway between the pulley and the flywheel.
17—ENG SERVICE INSTRUCTIONS Additional Service Disassembly or service of the air compressor beyond what is covered in this manual is not recommended. STORAGE OF COMPRESSOR OUTFIT 1. Review the Maintenance section on the preceding pages and perform scheduled maintenance as nec- essary.
18—ENG CAUSE CORRECTION PROBLEM TROUBLESHOOTING GUIDE PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, DISCONNECT POWER SOURCE FROM THE COMPRESSOR AND BLEED OFF ALL TANK AIR PRESSURE.
19—ENG CORRECTION CAUSE PROBLEM TROUBLESHOOTING GUIDE Motor will not run. Motor overload protection switch has tripped. Let motor cool off and reset switch by pressing the red button located on the end of the motor. If the overload still trips, check for defective capacitor.
20—ENG CORRECTION CAUSE PROBLEM TROUBLESHOOTING GUIDE Compressor is not supplying enough air to operate accesso- ries. (Continued) Loose belt. Hole in hose. Check and replace if required. Check valve restricted. Adjust belt tension. Remove and clean or replace.
21—ENG TROUBLESHOOTING GUIDE PROBLEM CAUSE CORRECTION Too many motor starts per hour. Consult Service Center. Check electrical hookup and installation data or con- sult electrician. Improper wiring gauge. Incorrect voltage. Water in pump crankcase; oil appears milky in color.
22—ENG COMPRESSOR DIAGRAM 10 4 3 5 6 1 2 8 11 7 13 9, 12 16 17 15 14 18.
23—ENG COMPRESSOR P ARTS LIST Key Part No . Number Description 1 BAL-T39 PUMP ASSEMBLY 2 MO-9071 MOTOR 3 DAC-278-1 PRESSURE SWITCH 4 TIA-4200 SAFETY VALVE 5 GA-360 PRESSURE GAUGE 6 SSV-6 BALL VALVE .
24—ENG COMPRESSOR PUMP DIAGRAM.
25—ENG PUMP P AR TS LIST Key Part No. Number Description 1 AC-0454 AI R I N LET ELBOW 2 BAL-1000345 VA L VE P L AT E 3 BAL-1000306 O ILSIGHT GLASS 4 BAL-1000519 OI L FILL PLUG 5 BAL-1000269 OIL PLUG.
26—ENG Assembly Consists Of : 1 . Filter Assembly 2 . Black Threaded Elbow 3 . Elbow Bolts (2) T o Install Air Filter: Attach elbow to pump using bolts provided. Tighten until snug. Insert threaded end of air filter assembly into elbow and tighten until snug.
27—ENG LIMITED W ARRANTY ONE YEAR FROM DA TE OF PURCHASE All merchandise manufactured by DeVilbiss Air Powe r Company is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user).
OWNERS MANUAL FOR TWO-ST AGE AIR COMPRESSOR Model No. LM7580V2C DeVilbiss Air Power Company • 213 Industrial Dr. • Jackson, TN 38301-9615 WARRANTY This product is covered by the DeVilbiss one year limited warranty. The warranty can be found in this General Manual or is available upon request.
デバイスDeVillbiss Air Power Company LM7580V2Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
DeVillbiss Air Power Company LM7580V2Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDeVillbiss Air Power Company LM7580V2Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。DeVillbiss Air Power Company LM7580V2Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。DeVillbiss Air Power Company LM7580V2Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
DeVillbiss Air Power Company LM7580V2Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDeVillbiss Air Power Company LM7580V2Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、DeVillbiss Air Power Company LM7580V2Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDeVillbiss Air Power Company LM7580V2Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。