DimplexメーカーS1 7KSの使用説明書/サービス説明書
ページ先へ移動 of 24
1 INST ALLA TION and OPERA TING INSTRUCTIONS Brine-to-W ater Heat Pump for Indoor Installation SI 1 1KS SI 14KS SI 7KS SI 9KS CE Order No.: 452231.67.01 FD 8504.
2 CONTENTS 1 PLEASE READ IMMEDIA TEL Y 3 1.1 Important Information 1.2 Legal Provisions and Directives 1.3 Energy-Efficient Use of the Heat Pump 2 PURPOSE OF THE HEA T PUMP 4 2.1 Application 2.2 Principle of Operation 3 BASELINE UNIT 4 4 ACCESSORIES 5 4.
3 READ IMMEDIA TEL Y 1.1 Important Information The heat pump is not secured to the wooden pallet. The heat pump must not be tilted more than max. 45° (in either direction). Do not lift unit by the holes in the panel assemblies! In the case of large-capacity heating circuits, the installed expansion vessel (24 litres, 1.
4 3 2 PURPOSE OF HEA T PUMP BASELINE UNIT PURPOSE OF THE HEA T PUMP 2.1 Application The brine-to-water heat pump is designed for use in existing or newly built heating systems. Brine is used as the heat carrier in the heat source system. Ground coils, ground collectors or similar systems can be used as the heat source.
5 5 4 ACCESSORIES 4.1 Brine Manifold The brine manifold ties the individual collector loops of the heat source system into a single main line which is connected to the heat pump. Integrated ball valves allow individual brine circuits to be shut off for venting purposes.
6 MOUNTING 7.1 General The following connections need to be established on the heat pump: - supply/return flow of the brine system - supply/return flow of the space heating and water heating system - .
7 CAUTION! MOUNTING pump installations where a power failure cannot readily be detected (e.g. holiday houses), the heating circuit must contain a suitable antifreeze product. The integrated expansion vessel has a capacity of 24 litres.This capacity is appropriate for buildings with a heated living space floor area of up to 200 m 2 .
8 9 COMMISSIONING CARE/CLEANING COMMISSIONING 8.1 General T o ensure proper commissioning it should be carried out by an after-sales service authorised by the manufacturer . Only then can an extended warranty period of 3 years in total be granted (cf.
9 10 CAUTION! 11 According to current knowledge, we recommend cleaning with a 5% phosphoric acid solution or , in the case that cleaning needs to be performed more frequently , with a 5% formic acid solution. In either case, the cleaning fluid should be at room temperature.
10 APPENDIX 12 12.1 DIMENSIONED DRAW- ING 1 1 12. 2 EQUIPMENT D A T A 12 12 .3 SCHEMA TICS 12.3.1 Characteristics .. 7KS 1 3 12.3.2 Characteristics .. 9KS 1 4 12.3.3 Characteristics .. 1 1KS 1 5 12.3.4 Characteristics .. 14KS 1 6 12. 4 WIRING DIAGRAMS 12.
11 APPENDIX: 12.1 DIMENSIONED DRAWING Dimensioned Drawing 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder Heating circuit pressure gauge Brine circuit pressure gau.
12 APPENDIX: 12.2 EQUIPMENT D A T A Equipment Data EQUIPMENT DATA for Brine-to-Water Heat Pumps for Heating 1 TYPE AND COMMERCIAL DESCRIPTION ..7KS ..9KS ..11KS ..14KS 2 MODEL 2.1 Type compact compact compact compact 2.2 Enclosure type acc. to EN 60 529 IP 20 IP 20 IP 20 IP 20 2.
13 12.3.1 Characteristics .. 7KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
14 12.3.2 Characteristics .. 9KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 14 16 18 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 3 3,5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
15 12.3.3 Characteristics .. 1 1KS APPENDIX: 12.3 SCHEMA TICS 0 2 4 6 8 10 12 14 16 18 20 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 0,5 1 1,5 2 2,5 3 3,5 4 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
16 12.3.4 Characteristics .. 14KS APPENDIX: 12.3 SCHEMA TICS 0 5 10 15 20 25 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Heating capacity in [kW] 35 50 Water outlet temperature in [°C] 0 1 2 3 4 5 - 1 0 - 5 0 5 1 01 52 02 53 0 Brine inlet temperature in [°C] Power consumption (incl.
17 12.4.1 Control .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS Mains power supply.
18 12.4.2 Load .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS Mains power supply Soft starter not available in brine-to-water unit 7KS.
19 Mains power supply Mains power supply or Utility company disable contactor Contact open = HP disabled The function of the back-up heater can be selected 2 nd disable input Contact open = HP disabled factory-wired to be field-connected, if required 12.
20 12.4.4 Legend .. 7KS to .. 14KS APPENDIX: 12.4 WIRING DIAGRAMS A 1 Wire jumper , must be inserted if no utility company disable contactor is required A2 Wire jumper , must be removed if 2nd disable.
21 Hydraulic Block Diagram APPENDIX: 12.5 HYDRAULIC BLOCK DIAGRAM Check valve Shut-off valve Overflow valve Safety assembly Circulating pump Expansion vessel Thermostat/manual valve Shut-off valve wit.
22 APPENDIX: 12.6 EC DECLARA TION OF CONFORMITY EC Declaration of Conformity Declaration of Conformity The undersigned Glen Dimplex Deutschland GmbH Division Dimplex Am Goldenen Feld 18 D-95326 Kulmba.
23 Notes.
24 Glen Dimplex Deutschland GmbH Subject to technical modifications Division Dimplex Fax +49 92 21/709-589 Am Goldenen Feld 18 ww w .dimplex.de D-95326 Kulmbach.
デバイスDimplex S1 7KSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dimplex S1 7KSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDimplex S1 7KSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dimplex S1 7KSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dimplex S1 7KSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dimplex S1 7KSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDimplex S1 7KSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dimplex S1 7KSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDimplex S1 7KSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。