DometicメーカーRM2812の使用説明書/サービス説明書
ページ先へ移動 of 12
1 Form No. 3105757.003 2/94 The Dometic Corp. LaGrange, IN 46761 © 1994 The Dometic Corporation REFRIGERA T OR MODEL RM2612 RM2812 INST ALLA TION & OPERA TING INSTR UCTIONS MODEL RM2612 AND RM281.
2 SECTION A. INST ALLA TION 2. VENTILA TION The installation shall be made in such a manner as to separate the combustion system from the living space of the mobile home or recreational vehicle. Openings in lower side vent for air supply or for venting of combustion products shall have a minimum dimension of not less than 1/4 inch.
3 5 . VENTILA TION HEIGHTS Refer to FIG 1., Page 2 Installation with roof Minimum Ventilation vent and lower side vent heights in: REFRIGERATOR INCHES MM RM2612 54 1372 RM2812 60 1524 LOWER VENT CUTOUT UPPER VENT CUTOUT 5-1/2" 21-9/16" 13-3/4" 23-3/4" NOTE : All cutout dimensions are +/– 1/8".
4 7 . INST ALLING REFRIGERA T OR IN ENCLOSURE NOTE : DO NOT install the appliance directly on carpeting. Carpeting must be removed or protected by a metal or wood panel beneath the appliance, which extends at least the full width and depth of the appliance.
5 9 . TESTING LP GAS SAFETY SHUT OFF The gas safety shutoff must be tested after the refrigerator is connected to LP gas supply. To test the gas safety shutoff, proceed as follows: A . Start the refrigerator according to the instructions, with 120 volts AC disconnected.
6 Do not use the chassis or vehicle frame as one of the conductors. Connect two wires at the refrigerator and route to the DC supply. 1 2 . INSTRUCTION FOR MOUNTING DOOR P ANEL The refrigerator is normally delivered without the door pan- els.
7 REFRIGERATOR KIT MODEL NO . COMPONENTS PART NO. RM2612 4A ROOF BASE 3103633.XX X * RM2812 ROOF COVER 3103634.XX X * LOWER SIDE VENT 3102277.XX X * POWE R VENT POWER VENT ASM. 3104131.00 2 ** (Island/through ROOF BASE 3103633.XX X * floor) ROOF COVER 3103634.
8 2 . CONTROL P ANEL LEGEND 1. Main Power Button ON/OFF 2. AUTO/MANUAL Mode Selector Button A . AUTO Mode indicator Lamp B . CHECK Indicator Lamp (GAS Mode Only) C . Climate Control Switch 3. OPERA TING INSTRUCTIONS A ) START-UP INSTRUCTIONS 1 ) 12 volt DC supply must be available for the electronic control to function.
9 will automatically switch to GAS. As soon as AC becomes available again, the control will switch back to AC operation. 3 ) If the CHECK indicator lamp (B) illuminates, the control has failed to ignite the burner on GAS.
10 When all frost is melted, dry the interior of the refrigerator with a clean cloth. Replace all food and start the refrigerator by pressing the ON/OFF button (1) to DOWN position. NOTE: On these models the drip tray/cup is on the rear side of the refrigerator.
11 free of soot. Heavy soot formation indicates improper functioning of the burner. The flue and burner both require cleaning in the following manner: 1 ) Unplug the refrigerator power cord from the 120 volt AC outlet (see FIG. 6). 2 ) Disconnect or shut off the 12 volt power to the refrigerator.
12 E . Flue baffle not inserted properly in flue tube. F. Improperly set thermostat. See Section C. Operating Instructions, Item 3. Paragraph F, and Item 4, Paragraph H . G. Burner dirty. Clean. See Section D. Maintenance & Service, Item 1. Periodic Maintenance, Paragraph E.
デバイスDometic RM2812の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dometic RM2812をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDometic RM2812の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dometic RM2812の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dometic RM2812で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dometic RM2812を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDometic RM2812の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dometic RM2812に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDometic RM2812デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。