T ype C40 / 110 822 6114 - 00 T .B. MBA 02/2009 English N 1 RMD 8501 RMD 8505 RMD 8551 RMD 8555 Installation Instructions Absorption Refrigerator for Recreation V ehicles.
© Dometic GmbH - 2009 - Subject to change - Printed in Germany 2 Dometic GmbH In der Steinwiese 16 D-57074 Siegen www .dometic.com.
1.0 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.
4 1.0 General On installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be used must be adhered to.
5 General 1.7 Declaration of Conformity Information INFORMA TION gives you supplementary and useful guidance when dealing with your refrige- rator . Environmental Tips ENVIRONMENT AL TIPS gives you useful gui- dance for saving energy and disposal of the appliance.
6 Safety instructions 2.0 Safety instructions This refrigerator is designed for installation in recr eation vehicles such as caravans or motorhomes. The appliance has been type- approval tested for this application in accor- dance with the EC Gas Directive.
7 Description of model Fig. 1 Model number Product number Serial number Electrical rating details Gas pressur e 2 2 1 1 3 3 4 4 5 5 RM 8 5 0 1 1 5 D Refrigerator Mobile / Mobile Absorption Refrigerato.
8 Description of model 3.3 T echnical data Model Dimensions Gross capacity Rating details Consumption * Net Ignition H x W x D (mm) with mains/battery electricity/gas weight Piezo Automat Depth incl. door freezer compartment over 24hr s Subject to technical changes.
9 Installation 4.0 Installation instructions The unit and the e xhaust duct system must be in principle installed so that it is accessible f or maintenance work, can be easily installed and dismantled and remov ed from the vehicle wit− hout great eff or t.
10 Installation Another unfavourable method of rear installation is to install the air int ake and exhaust grilles (Fig. 9) at the side wall of the recreation vehicle. The air-heat recirculation is very restricted which means that heat exchangers (condenser , absor- ber) cannot be adequately cooled.
11 Installation Fig. 7 Fig. 8 Fig. 9 Fig. 10 The flexible sealing is pressed into the gr oove running around the housing. Pr ess the side pro- vided with the sealing knob firmly into the groo- ve. T ake care that the sealings uniformly abut the housing.
12 Installation Fig. 1 1 The ventilation grilles must have an open cross-section of at least 400 cm². This is achieved by using the Dometic LS300 absorber ventilation and air extraction system which has been tested and approved for this purpose. 4.2.
13 Installation Correct mounting of the lower ventilation grille facilitates access to the connections and functional parts during maintenance. 4.3 Installing the ventilation system Fig.
Fig. 26 14 Fig. 25 Insert winter cover . 5 The exhaust gas duct system must be made in such a manner as to achieve a complete extrac- tion of combustion products to the outside of living space. The flue gas is vented directly through the upper grille.
15 The refrigerator must be installed draught-pr oof in a recess (also r efer to Section "4.1.3"). The measurements of the r ecess are stated in the table below . Push the appliance far enough into the recess until the fr ont edge of the refrigerator casing is aligned with the front of the r ecess.
16 Installation 4.7 Insert the decor panel Fig. 31 Fig. 32 Remove the lateral ledge (1) from the door (ledge is attached, not screwed). Shift decor panel (2) aw ay from the door and inser t the new decor panel. Re−attach ledge (1) . Fig. 29 Decor panel with frame Frameless decor panel Fig.
17 Installation Observe the regulations stated in section 4.1. This refrigerator is pro vided f or installati on within liquid gas equipment in compli− ance with EN1949 and must be run e xclu− sively on liquid gas (pr opane , b utane) (no natural gas, town gas).
18 Installation Fig. 35 The electrical installation must be in accordance with the national regulations of the respective countries. The connection cables m ust be r outed in a way to pre vent contact with hot compo nents of the unit/burner or with sharp edges.
19 Installation 4.9.3 T erminal strip Contacts : A = Ground heating element DC B = Positive connection, heating element DC C = Ground electr onics D = Positive connection, electronics D+ = Alternator signal S+ = AES input signal from solar char ge r egulator Fig.
20 Installation Fig. 39 Wiring diagram RMD8xx1 : 4.9.5 Wiring diagram For MES and AES it is compulsory to provide a permanent 12V DC supply at the terminals C/D (permanent voltage supply for functional electronics).
21 Installation Wiring diagram RMD8xx5 : For MES and AES it is compulsory to provide a permanent 12V DC supply at the terminals C/D (permanent voltage supply for functional electronics).
22 Einbau.
23 Einbau.
24 Dometic GmbH In der Steinwiese 16 D-57074 Siegen www .dometic.com.
デバイスDometic RMD 8551の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dometic RMD 8551をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDometic RMD 8551の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dometic RMD 8551の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dometic RMD 8551で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dometic RMD 8551を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDometic RMD 8551の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dometic RMD 8551に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDometic RMD 8551デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。