ULTRA FLAME FIREPLACE GAS INSERT INSTALLATION AND OPERATING INSTRUCTIONS FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. FOR YOUR SAFETY IF YOU SMELL GAS : 1. OPEN WINDOWS 2.
TABLE OF CONTENTS : GENERAL INFORMATION :............................................................................. 2 WARNING :........................................................................................................ 3 SPECIFICATIONS :.
GENERAL INFORMATION : The ULTRA FLAME is a high efficiency firepl ace gas insert with an input rating of 30 000 Btu/h with natural gas and 26 000 Btu/h with propane. It features a millivolt valve with a constant pilot. This lets you choose between a wall mounted switch, a wireless remote control to turn on or off the main flam e at will.
WARNING * INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER. * DO NOT BURN WOOD OR ANY OTHER MATERIAL IN THE GAS INSERT. * HOT WHEN IN OPERATION. KEEP, FURNITURE, CLOTHING AND FLAMMABLE MATERIAL AWAY FROM THE APPLIANCE.
SPECIFICATIONS : Dimensions : height : 20” width : 28” depth : 15” face plate : 44 5/16” x 27 1/2” glass : 14 1/2 x 30 5/16 1400 ° F clear ceramic F u e l : N a t u r a l G a s P r o p a n e Input : 30 000 26 000 Btu/h Manifold pressure : 3.
TOP, SIDE AND FRONT VIEWS : 5.
INSTALLATION : 1. When the masonry fireplace that will r eceive the ULTRA FLAME gas insert is thoroughly cold, remove all ashes and vacuum clean. 2. Remove the glass front from the gas insert following page 11 instructions. 3. Remove the burner and firebox bottom plate from the gas insert following page 12 instructions.
11. Secure the liner to the 4” connector on the top of the ULTRA FLAME with three metal screws. 12. Push the ULTRA FLAME back in the fireplace while pulling the draft hood in place. To do so, fix two ropes to the dr aft hood sliders. Make sure the draft hood front lip is squeezed under the steel angl e to prevent any motion.
13. Install a 1/8” NPT plugged tapping for test gauge connection immediately upstream of the gas supply connection to the appliance. 14. Install a shutoff valve to the gas line. Tighten securely using a pipe joint compound. 15. Install a 3/8” flex connector to connect the shutoff valve to the gas valve on the fireplace.
- Install the wall switch in a convenient location. Route a proper sized wire from the switch or the thermostat to the gas valve. Distance between valve Wire gage and switch 8 ’ 2 2 1 2 ’ 2 0 2 0 ’ 1 8 3 2 ’ 1 6 5 0 ’ 1 4 - Connect the wires in serial with the face plate flame switch ( green wires ).
20. Install the firebox bottom plate and burner following page 12 instructions. 21. Install the 4 logs on the burner as shown on page 13. 22. If so desired, install the embers kits as shown on page 16. 23. Install the glass front following page 11 instructions.
GLASS FRONT REMOVAL CLEANING AND INSTALLATION : * To remove the glass front, unscrew the six screws holding it in place as shown. CAUTION : Hold the glass while unscrewing to prevent it from falling. * Clean the glass only with liquid cleaners or soaps and water, do not use abrasive cleaners which could remove the coating on the glass.
BURNER REMOVAL AND INSTALLATION : REMOVAL : 1. Slide the burner to the left and pull toward you. 2. To gain access to the fan, also remove the firebox bottom plate. INSTALLATION : 1. Put the bottom plate back in place. 2. Put the burner assembly back in the firebox and push to the right until it touches the firebox side.
LOG INSTALLATION : 1. Remove the glass front as described on page 11. 2. Install the longer log in back of the firebox with locating grooves on top. 3. Install the 14” log in the front of the fire box and to the right. Make sure the log is pushed against the metal retainer on the burner face.
FACE PLATE ASSEMBLY AND INSTALLATION : ASSEMBLY : 1. Bolt the face plate top piece to the left piece using two #10-24 x 1/2 bolts and nuts (B). 2. Place both louver assemblies in position with their pivot rod inserted through the face plate side pieces holes (C).
INSTALLATIONS : 1. Screw the air deflector on the unit as shown using three #10 x 1/2 metal screws. 2. Bring the face plate in position on the gas insert taking care to slip the air deflector between the top louver and the bottom of the top piece. Secure using four #10 x 1/2 metal screws (D).
REFRACTORY PANELS INSTALLATIONS : 1. Remove the front glass as described on page 11. 2. Remove the logs from the firebox. 3. Install the two sides refractory panels a nd pull them forward as mush as possible to help insertion of the back panel. 4. Place the back refractory against the back of the firebox.
OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS : 1. Open the bottom louvers of the face plate to reach the control. 2. Turn the gas valve knob to the “OFF” position and wait 5 minutes. Note : You have to depress the gas valve knob to turn from “PILOT” to “OFF” or from “OFF” to “PILOT”.
MAINTENANCE INSTRUCTIONS : TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. * The venting system and the gas insert should be inspected at least once a year. * Remove the glass front and the logs clean them if necessary.
OPTIONAL PARTS ITEM DESCRIPTION Part No QTY Face plate, silver gray enamel E5422 1 Face plate, black enamel E5420 1 Face plate, gold E5415 1 Face plate, charcoal painted E5416 1 Face plate, black pain.
____________________________ LIMITED 5 YEARS WARRANTY ____________________________ DROLET STOVES AND FIREPLACES INC. here by warrants the quality of its fireplace gas insert against manufacturing defects.
デバイスDrolet 36C03U TYPE 139の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Drolet 36C03U TYPE 139をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDrolet 36C03U TYPE 139の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Drolet 36C03U TYPE 139の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Drolet 36C03U TYPE 139で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Drolet 36C03U TYPE 139を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDrolet 36C03U TYPE 139の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Drolet 36C03U TYPE 139に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDrolet 36C03U TYPE 139デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。