3MメーカーGD-6の使用説明書/サービス説明書
ページ先へ移動 of 16
3 Macurco ™ Combustible Gas Detector , Controller and T ransducer User Instructions IMPORT ANT : Keep these User Instructions for reference. GD-6.
1 T ABLE OF CONTENTS GENERAL SAFETY INFORMA TION ................................................................................................................ 2 Intended Use ..........................................................................
2 3 W WARNING GENERAL SAFETY INFORMA TION Intended Use The 3M™ Macurco™ GD-6 Combustible Gas Detector , Controller and T ransducer is a low voltage device with selectable 4-20mA output, buzzer and digital display options.
4 5 Ifyouhaveanydoubtsabouttheapplicabilityoftheequipmenttoyourjobsitua tion, consultanIndustrialHygienistorcall3M Macurco T echnical Ser vice at 1-800-243-4630. In Canada, call 1-800-267-4414.
6 7 Installation 1. The 3M™ Macurco™ GD-6 Combustible Gas Detector mounts on a type 4S electrical box supplied by the contractor . 2. Connect the 3M™ Macurco™ GD-6 Combustible Gas Detector to Class 2 power supply only .
8 9 T ypical Multiple 3M™ Macurco™ GD-6 Combustible Gas Detector Installation INSTALLA TION NOTES 1. One sensor per 900 square feet (approximately). 2. If the gas used is natural gas (methane) or Hydrogen (H2) mount the 3M™ Macurco™ GD-6 Combustible Gas Detector high on a wall about one foot down from the ceiling.
10 11 GD-6 Main Fan Power 120VAC ALARM 120VAC Power Exhaust Fans coil coil power output GD-6 – + power output – + 8 7 6 5 4 4 3 3 2 2 1 1 1 1 3 3 4 5 6 7 8 9 2 24 V RET N.
12 13 T o change settings, remove the Philips screw on the front of the 3M™ Macurco™ GD-6 Combustible Gas Detector . Pull off the front cover of the unit. Gas Selection T o select the Gas Option , in normal mode, press the Next button once to display the current gas selection ( mE is Methane, Pro is Propane and Hy is Hydrogen) .
14 15 Selecting Fan Minimum Run Time – “Frr” T o select the Fan Minimum Runtime setting, in normal mode, press the Ne xt button twice to get to “Con” or the Configuration menu. Then press the Enter button to enter the Con menu. The ninth selection is the “Frr” or Fan Minimum Run Time.
16 17 Operation T est 1. Remove the single screw in the middle of the front cover of the 3M™ Macurco™ GD-6 Combustible Gas Detector . 2. Remove the front cover . 3. Observe the LED light on the front of the 3M™ Macurco™ GD-6 Combustible Gas Detector .
18 19 Gas T esting T esting the Fan Relay Note: The gas concentration to activate the fan relay depends on the setting. 1. Remove the Philips screw on the front of the 3M™ Macurco™ GD-6 Combustible Gas Detector . Remove the front cover . 2. Connect the 10% LEL cylinder of Combustible Gas to the regulator .
20 21 5. The 4-20mA output should ramp up from 4mA in clean air to 20mA at 50% LEL. See 4-20mA diagram in these User Instructions . Note: If the 4-20mA output does not ramp up within 2 minutes, consider these possibilities: a. Gas cylinder is empty , check the pressure gauge.
22 23 7. Press the Enter button and the display will read 10 alternating with the gas, mE, Pro or Hy (blinking), indicating the sensor is looking for gas. 8. Start applying gas to the gas sensor . Note: The sensor will look for the gas for 45 seconds.
24.
3M Occupational Health and Environmental Safety Division 3M Center , Building 0235-02-W-70 St. P aul, MN 55144-1000 Printed in U.S.A. © 3M 2008-2011. All rights reserved.
Requester: Farrel Allen Creator: deZinnia File Name: 34870758629.indd Structure #: SS-41964 Date: 6/17/11 Printed Colors – Front: Printed Colors – Back: Match Colors: This artwork has been created as requested by 3M. 3M is responsible for the artwork AS APPROVED and assumes full responsibility for its correctness.
デバイス3M GD-6の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
3M GD-6をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこには3M GD-6の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。3M GD-6の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。3M GD-6で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
3M GD-6を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又は3M GD-6の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、3M GD-6に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわち3M GD-6デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。