EatonメーカーTRS 3064の使用説明書/サービス説明書
ページ先へ移動 of 13
TRS 3064 Installation, Operation and Maintenance of the Airflex@ Timing Rotorseal and Cam Limit Switch Revised: Feb. 1, 1982.
1.0 Operation Throughout this manual, there are a number of Hazard Warnings that must be read and understood in order to prevent possible personal injury and/or damage to the equipment. Carefully read these warn- ings. They are included to protect you! 1.
Figure 1 illustrates the cams assembled in the timing section of both devices and their relationships. 1 Cam No. 2 Cam Insert No. 3 Cam No. 4 Cam insert No.
Cam No. 3 (28 and 28A) monitors the effective- ness of the press braking system at the top of the stroke. When cam No. 3 is positioned according to Paragraph 2.3, deviations in stopping position greater than + 15” from top dead center will be detected.
2.1.2. To a) b) c) d) e) f) g) h) i) j) mount the timing rotorseal: Make sure that the air tube “O” rings (2) are in place. Install the plastic insert (37A) in the head of the drive screw (37). Install drive screw. Tighten the screw, being careful not to distort the end plate (36).
Before mounting the timer, check to be sure its direction of rotation corresponds to that of the shaft. Fasten the flange to the shaft with lockwashers and cap screws. Refer to appropriate paragraph and mount second timer. W iring instructions are given in Paragraph 2.
m) Retighten the jam nuts (30) and repeat Steps “f”, “g” and “h”. n) Repeat this procedure as necessary to ob- tain the desired stopping position. 2.3.2 Long Operation: This feature is provided so an adjustment can be made to extend the LS4 open time and accommodate presses with long strokes and/or slow crankshaft speeds.
Breaker Point Opening Gap: This gap is preset at the factory on new units at time of assembly. A gap setting of .040” to .050” must be maintained at all times. The opening gap must be checked regularly and reset when required. To inspect for proper opening gap: a) b) c) d) e) h) i) j) k) Position the crankshaft at top dead center.
o) P) q) r) s) t) u) v) w) Align No. 5 cam with previously establish- ed top stop mark by rotating cam adjusting knob. Maintain No. 5 cam alignment by holding adjusting knob. Rotate No. 3 cam so that indicator groove lines up with the fiber cam follower on LS3 breaker point.
.
Item No. - 6. 20. 22. 23. 24. 25. 26. 27. 28. 28A 29. 30. 31. 32. 33. 33A 34 38. 40. 41. 42. 45. 46. 47. Part No. Description 302276 159 x 41 139 x 12 See table C See table C 201854 See table C 201869.
FOOT MOUNTED CAM LIMIT SWITCH Part No. for Optional Cam No. 3 (Item No. 28A), is as follows: 203002 (For clockwise and clockwise 30” dwell) 203087 (for c’clockwise and c’clockwise 30” dwell) Eaton Corporation Airflex Division Cleveland, Ohio 44144 PWNTED IN u.
PDF form at Form ML-31 8 Revised September 3, 1997 Eaton Cor poration Airflex Division 9919 Clinton Road Cleveland, Ohio 44144 Printed in U.S.A. EAT ON PROD UCT WARR ANTY Subject to t he c ondit io ns.
デバイスEaton TRS 3064の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Eaton TRS 3064をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEaton TRS 3064の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Eaton TRS 3064の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Eaton TRS 3064で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Eaton TRS 3064を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEaton TRS 3064の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Eaton TRS 3064に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEaton TRS 3064デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。