ElectroluxメーカーCF205VS01の使用説明書/サービス説明書
ページ先へ移動 of 20
Part No. F40BP73750002 Form No. BP7375-2 U.L. Model No.: CF205 READ AND SA VE THESE INSTRUCTIONS Ceiling F an Owner's Manual Model Number s HIGHPOINTE ™ Net W eight: 22.
2 WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
3 U.L. Model No.: CF205 This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan T ools Needed for Assembly One Phillips head screwdriver One stepladder One wire cutter One wire stripper MA TERIALS Wiring outlet box and box connectors must be of type required by the local code.
4 U.L. Model No.: CF205 Gener al Your Emerson ceiling fan comes supplied with a Fan/Light Remote Control which consists of a remote control (transmitter) and a remote control receiver mounted under the ceiling cover. This system allows you to regulate your ceiling fan speed and light intensity.
5 U.L. Model No.: CF205 Ho w to Assembly Y our Ceiling F an (continued) Your ceiling fan can be assembled with the light kit and glass or without the light kit and glass. To assemble without the light kit and glass, you will use the no-light cover plate.
6 U.L. Model No.: CF205 Ho w to Assembly Y our Ceiling F an It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed (as shown in Figure 6) could result in the fan falling.
7 U.L. Model No.: CF205 Ho w to Assembly Y our Ceiling F an (continued) 13. Slide the rod support assembly up the downrod until the threaded holes in the rod support align with the holes in the decorative rod assemblies (Figure 9).
8 U.L. Model No.: CF205 Ho w to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 11). FLOOR CEILING A T LEAST 7' Figure 11 WARNING ! The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
9 U.L. Model No.: CF205 Ho w to W ir e Y our Ceiling F an GREEN GROUND WIRE FROM HANGER BRACKET RECEIVER RED WIRE RECEIVER WHITE WIRE F AN WHITE WIRE F AN BLACK WIRE ANTENNA A C I N N AC IN L FOR LIGH.
10 Ho w to W ir e Y our Ceiling F an (continued) ST ANDARD ON-OFF WALL SWITCH OR OPTIONAL SW406 WALL CONTROL BLACK BLACK WHITE RED BLACK WHITE HANGER BALL GREEN WIRE (GROUND) FROM HANGER BALL AND HANG.
11 CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver. 1. Detach the light kit plate from the fan motor/hous- ing assembly by removing one screw and loosen- ing the two other screws (located in the keyholes).
12 4. Carefully tuck blue and white wires from motor up into the fan motor/housing assembly (Figure 21). 5. Place the cover plate onto the fan motor/housing aligning the three flat areas on the top flange of the cover plate with the three pins on the inside of the fan motor/housing (Figure 21).
R emote Contr ol Pr ocedures (continued) 13 U.L. Model No.: CF205 COUPLING COVER MOTOR HOUSING REVERSE SWITCH Figure 24 Setting Operating F r equency of T r ansmitter Your remote control transmitter has code switches which must be set in one of 32 possible code combi- nations.
14 Accessories This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or acces- sories not designated for use with this product by Emerson Electric Co.
15 U.L. Model No.: CF205 T r ouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1.
16 U.L. Model No.: CF205 Instr uction to the User (if device contains a digital de vice) This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
17 U.L. Model No.: CF205 Notes.
18 U.L. Model No.: CF205 R epair Par ts 3 2 1 5 4 26 14 15 6 7 17 17 16 18 9 23 11 28 27 8 25 13 10 20 19 22 24 21 22 12.
19 U.L. Model No.: CF205 R epair Par ts Listing Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545.
Part No. F40BP73750002 Printed in China 09/12 Form No. BP7375-2 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 U.
デバイスElectrolux CF205VS01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Electrolux CF205VS01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはElectrolux CF205VS01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Electrolux CF205VS01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Electrolux CF205VS01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Electrolux CF205VS01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はElectrolux CF205VS01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Electrolux CF205VS01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちElectrolux CF205VS01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。