ElmoメーカーCBL-CELAUX-5の使用説明書/サービス説明書
ページ先へ移動 of 17
Cello Digital Servo Drive Cable Kits Main Feedback: CBL-DFDBK (general purpose) CBL-DFDBK-5 Encoder: CBL-MTRENC2 (for SAR, SA,SB,SC) CBL-MTRENC2-5 Encoder: CBL-MTRENC4 (for SE) CBL-MTRENC4-5 Aux. Feedback: CBL-CELAUX -5 CBL-CELAUX-5 General I/O: CBL-CELIO1 -5 (J1) CBL-CELIO1-5 General I/O: CBL-CELIO2 -5 (J2) CBL-CELIO2-5 Aux.
Important Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary informatio n belonging to Elmo Motion Control Ltd. Such information is supplied solely for the purpose of assisting users of Elmo’s Cello servo drives in assembling the required cables for their drive.
Contents 1. Introduct ion ................................................................................................................ ............. 1 1.1 Cello Connectors ...........................................................................
1. Introduction This document provides the wiring details fo r the cables used to connect Cello digital servo drives with the end-user application. The servo drive-side pinouts are provided in Chapter 3 of the drive’s installation guide. The cables come in two lengths: 2 meters (6 ½ feet) and 5 meters (16 ½ feet).
Type Function Port Connector Location 8-pin RJ-45 CANopen CAN 8-pin RJ-45 CANopen CAN 15-pin D-Sub (high-density) Feedback B Feedback B 8-pin RJ-45 RS-232 RS-232 Table 1-3: The Cello’s Communications and Feedback B Connectors 1.2 Cable Cross-Reference Cable Application Cable Part.
2. Cable Kits Several Cable Kits can be purchased from Elmo. Each contain a set of 8 cables. The -5 suffix on the kits and on the cables (CBL-DFDBK-5 fo r example) indicate that the cables are 5m long. Cables and kits without that suffix are 2m long (except for CBL-RJ45CAN2 which is 20cm long).
3. Main Feedback Cables The main feedback cables are made of 24-AWG sh ielded cable. There are 3 types of feedback cables, all use a 15-pin D-sub plug which connects to the FEEDBACK A port on the Cello. • The General-Purpose Main Feedback Cable (CBL-DFDBK) is open on the motor side so that it can be connected to customer-specific connectors.
3.2 Encoder Cable (CBL-MTRENC2 -5 for SAR, SA, SB, SC) D-Type Pin No. Color Socket Pin No. Signal Pair Description 1 10 Green Yellow 11 9 HC HB pair Hall sensor C input Hall sensor B input 2 Pink 7 HA.
3.3 Encoder Cable (CBL-MTRENC4 -5 for SE) D-Type Pin No. Color Socket Pin No. Signal Description 1 Green P HC Hall sensor C input 10 Yellow M HB pair Hall sensor B input 2 Pink K HA Hall sensor A inpu.
4. Auxiliary Feedback Cable (CBL-CELAUX -5) The auxiliary feedback cable is a 24-AWG shielded cable. It is connected using an 15-pin Hi-density D-sub plug which connects to the Cello’s FEEDBACK B port.
5. General I/O J1 (CBL-CELIO1 -5 ) The digital input cable is a 24-AWG shielded cable. It is connected using an 15-pin Hi- Density D-sub socket. Pin Color Signal Pair Function Pin Position 1 Orange IN.
6. General I/O J2 (CBL-CELIO2 -5 ) The digital output cable is a 26-AWG shielded cable. It is connected using a 15-pin Hi- Density D-sub plug. Pin Color Signal Pair Function Pin Position 1 Orange IN5 .
7. Auxiliary Power Cable (CBL-CEL24 -5 ) The auxiliary power cable is a 24-AWG shie lded cable terminated by pins on the SimplIQ side. The pins are screwed into the 2-pole Pheonix Terminal Block provided with the Cello.
8.2 Motor Power Cable (CBL-MTRPWR1CEL -5 ) CBL-MTRPWR1CEL -5 is a 24-AWG shielded cable in which each wire, on the SimplIQ drive side, is connected to a pin terminal and the wires on the motor side are connected to a 4-pole socket. This cable is designed for connecting a Cello to a Metronix APM-SAR, SA, SB or SC motor.
9. Communication Cables The communication cables use 26-AWG twisted pair shielded cable. They are connected using an 8-pin RJ-45 plug. Elmo drives can communicate using the following options: RS-232, full duplex CANopen 9.1 RS-232 Option (CBL-RJ452321 -5 ) RJ45 Pin No.
9.2 CAN Option (CBL-RJ45CAN1 -5 ) RJ45 Pin No. Color D-type Female Pin No. Signal Description 1 Green 7 CAN-H CAN_H bus line 2 Yellow 2 CAN_L CAN_L bus line 3 White 3 CAN_GND CAN ground 4 — — — .
9.3 CAN Option (CBL-RJ45CAN2) Cable CBL-RJ45CAN2 is 20 cm long, it is used for “daisy-chaining” CAN nodes. On the Harmonica this cable is connected to the External Dual Can Port.
デバイスElmo CBL-CELAUX-5の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Elmo CBL-CELAUX-5をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはElmo CBL-CELAUX-5の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Elmo CBL-CELAUX-5の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Elmo CBL-CELAUX-5で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Elmo CBL-CELAUX-5を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はElmo CBL-CELAUX-5の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Elmo CBL-CELAUX-5に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちElmo CBL-CELAUX-5デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。