RSU-200 Remote Control Extension Unit for PTC-200C / PTC-100S / PTC-110R INSTRUCTION MANUAL PART NAMES Infrared Sensor LED DC IN RS-232C IN Terminal Composite Video Out (RCA pin jack) Camera IN.
DIP SWITCH SETTING Be sure to turn ON No.1 of the DIP Switch(4) on the bottom of the Camera before turning ON the power supply to the Camera. CONNECTION OPERATION The infrared emitting window of the wireless remote controller is requested to point at the Infared Sensor of RSU-200 whenever the controller is in use.
INTERNAL SWITCH When the unit is used for a long distance, select "LONG" ON the internal switch of RSU-200. It is recommended to use the unit within 500m(1640 ft) from PTC Cameras when the 5C-2V cable is used. SPECIFICATIONS Power source 12V DC Power consumption 2.
RS-232C SPECIFICATIONS Pin assignment Pin No. Code 1 DTR 2 DSR 3 TXD 4 GND 5 RXD 6 GND 7 NC 8 NC Transmission specifications * Full duplex start-stop sync.