AC P ow er For Business-Criti cal C on tinuity™ Li eber t ® PSI XR ™ Us er Man ual–1000/1500/2200/3000 , 120V A C.
.
i T ABLE OF CONTENTS I MPORT ANT S AFETY I NSTRUCTION S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ii 6.0 C OMMUNICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 6.1 DB-9 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 I MPORT A NT S AFETY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual co ntains important instructio ns that should be followed du ring installation and ma inte- nance of the UPS. • Intended for installat ion in a temperature-co ntrolled, indoor area free of conductive contaminants.
2 CONDITIONS OF USE —The input supply outlet must be with in 6 ft. (1.8m) of the UPS and be eas- ily accessed. This UPS provides conditioned powe r to connected equipment. It is no t intended for use w ith life-sup- port and other designated “critica l” devices.
3 G LOSSARY OF S YMBOLS Risk of ele ctrical shock Indicates caution followed by important instructions Indicates the unit contains a valve-regulated, lead-ac id battery Recycle DC voltage Equipment gr.
Introd uction 4 1.0 I NTRODUCTION The Liebert PSI ™ XR is a 2U, line-interactive UPS that may be installed in a rack or used as a tower UPS. Status indicators on the front of the Liebert PSI XR display load level, battery level, buck/boost, site- wiring fault, overload, battery status and UPS op eration.
Introd uction 5 Figure 3 2200—rear view Figure 4 3000—rear view DC 48V OUTPUT EPO INPUT VOLT AGE=110V VOLT AGE=120V VOLT AGE=127V 2 1 FUNCTION Network Surge Protection USB Port DB-9 Port (Conta ct.
What’ s Included 6 2.0 W HAT ’ S I NCLUDED The Liebert PSI XR is shipped with the following items: • Multi-Language User Manual on CD • Liebert MultiLink Software and User Manu al, downloadable at multilink.
Installation 7 3.0 I NST ALLATION 3.1 Prep aration The Liebert PSI XR may be installe d in either a tower or rack conf iguration. Determine the method that suits the applica tion and proceed. Decide where to install the Liebert PSI X R. The UPS must be installed indoor s in a controlled envi- ronment.
Installation 8 3.2 T ower UPS Installation See Figure 7 when using the Liebert PSI XR in a tower configuration. Figure 7 T ower conf iguration—att ach T ower S tands Step 1 Step 2.
Installation 9 3.3 Rack-Mount U PS Conversion and Inst allation See Fi gure 8 when installing the Liebert PSI XR in a rack. Ex ternal battery cabinets are inst alled in same manner.
Installation 10 3.4 Orient Display for Inst allation The Liebert PSI XR features a rotating display th at may be oriented for either tower or rack installations. To set the display for your instal lation, pu ll out on the display and rotate it un til it is orient ed correctly, then press it i nto the UPS until it is seated.
Installation 11 3.7 Connect Network Surge protection Connect a 10 base-T/100 network cable to the networ k surge protection IN jack on the rear of the UPS. Connect from the OUT jack with ne twork cabling to network equipment (see Figure 11 ). Figure 1 1 Connect network surge prot ection 3.
Installation 12 3.9 Set Up Liebert MultiLink sof tware To start using Liebert MultiLink (sof tware and user ma nual availa ble at multilink.liebert.com ): • Install th e software. See the Liebert MultiLink quick-start guide or user manual for installation instructions.
Installation 13 3.1 1 External Battery Cabinet Inst allatio n Optional Liebert external battery cabinets may be connec ted to the UPS to prov ide additional battery run time. External battery cabinets are designed to be pla ced all on one side of the UPS or stacked beneath the UPS.
Installation 14 Figure 15 Connect battery cabinet s to UPS See Table 8 for approx imate battery run times. DC 24V OUTPUT INPUT EPO VOLTAGE=1 10V VOLTAGE=120V VOLTAGE=127V 2 1 FUNCTION.
Controls and Indica tors 15 4.0 C ONTROLS AND I NDICATORS Buttons on the front panel displa y control the Lieb ert PSI XR. Eight L EDs indica te the UPS’s statu s.
Controls and Indica tors 16 4.1 Control Buttons 4.1.1 On/Alarm Silence/Manual Self-Diagnostic T est This button controls output power to co nnected load (s).
Controls and Indica tors 17 4.2.3 Battery Level Indicator The five LEDs illuminate with a steady glow to indicate battery capacity. Battery capacity is shown for five second s after the Status Change button is pressed. The LEDs show the battery capacity as a range, ± 5% The LEDs’ battery level meanings and colors are: 4.
Operational Modes 18 5.0 O PERATIONAL M ODES 5.1 Normal Mode When the UPS is in Normal Mode, the No rmal Mode Indicato r illumina tes green. 5.2 Buck/Boost Mode The Automatic Voltage Regulator (AVR ) circuitry compensates for fluctu ations in utility power, su ch as voltage surges and sags.
Communication 19 6.0 C OMMUNICATION 6.1 DB-9 Connector The UPS has a DB-9 (9 pin female) connector on the rear to allow UPS statu s communications with a computer running Liebert MultiLink software in co ntact closure mode. The conne ction provides On Battery and Low Battery notification.
Communication 20 6.4 UPS Communications The Liebert PSI XR is equipped with a Liebert In telliSlot port to provid e advanced communication and monitoring options.
Battery Maintenance 21 7.0 B ATTERY M AINTENANCE 7.1 Battery Charging, S torage The batteries are valve-regulated, nonspillabl e, lead acid and must be kept charged to retain their design life . The Liebert PSI XR con tinuously charg es the batteries wh en connected to th e utility sup- ply, even while the UPS is switched Off.
Specifications 22 8.0 S PECIFICATIONS T able 6 Liebert PSI XR specifications Model Number PS1000RT3-120XR PS1000RT3120XRW PS1500RT3-120XR PS1500RT3120XRW PS2200RT3-120XR PS2200RT3120XRW PS3000RT3-120XR PS3000RT3120XRW Power Rating, VA/W 1000VA/900W 1500VA/13 50W 1920VA/1920W * 3000VA/270 0W Dimensions, W x D x H, in (mm) Unit 17.
Specifications 23 T able 7 Battery cabinet specifica tions Model Number PSRT3-24VBXR PSRT3-48VBXR Used w/UPS Model PS1000RT3-120XR PS1000RT3120XRW PS1500RT3-120XR PS1500RT3120XRW PS2200RT3-120XR PS2200RT3120XRW PS3000RT3-120XR PS3000RT3120XRW Dimensions, W x D x H, in (mm) Unit 17.
Specifications 24 T able 8 Liebert PSI XR battery run times Number of Batteries Load % 1000 1500 2200 3000 Internal Battery 10 83 82 76 75 20 52 48 48 47 30 31 28 28 28 40 18 17 17 17 50 15 13 14 13 6.
Specifications 25 Internal battery + 4 External Battery Cabinets 10 790 627 483 3 30 20 494 371 303 2 04 30 360 264 221 1 48 40 283 204 174 1 16 50 233 167 143 95 60 198 141 122 76 70 172 122 106 66 8.
Trou bleshooting 26 9.0 T ROUBLESHOOTING The informatio n below indicates va rious symptoms a user may encoun ter if the Liebert PSI XR expe- riences a problem. See Table 9 for suggested solutions. 1. An alarm sounds, alerting that the UPS requires attention.
.
EmersonNetworkPower.com Ensuring The Hi gh Av ailab ilit y Of Mission-Critic al Data And Ap plic ations. Emerson Net work P ower , the global leader in enabling business-critical continuity , ensures .
デバイスEmerson 3000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson 3000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson 3000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson 3000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson 3000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson 3000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson 3000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson 3000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson 3000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。