EE542-1 Z I Installation Manual Smart Energy Programmable Thermostat + Energy Monitor.
1 2 3 3 4 6 9 14 17 19 20 - 22 Back Cover Contents Introduction Getting Started Installing the Thermostat Quick Guide Step 1: Remove the Old Thermostat Step 2: Mount the New Thermostat Step 3: Configu.
Introduction • About this Guide • System Compatibility 1 This guide describes how to install and configur e your new Smart Energy thermostat. This product r eplaces most thermostats, including those that work with: • Standar d Heat and Cool Systems • T wo-Stage H eat and T wo-Stage Cool Systems • Air Source Heat P ump (with Aux.
Getting Started N ote: This product r equires a 24v AC power supply via the C terminal for operation. • Thermostat (1) • Wall anchors (2) • Mounting scr ews (2) Required Items • Flat blade scr.
3 T o prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or cir cuit breaker box until installation is complete. CA UTION Quick Guide • T urn of f power at the breaker . • Remov e cover from old ther mostat to expose wires.
4 T o prevent electrical shock and/or equipment damage, disconnect electr ic power to system at main fuse or cir cuit breaker box until installation is complete. CA UTION This product does not contain mercury . However this product may r eplace a product that contains mercury .
5 Remov e the Old Thermostat Important: Do not let wires fall back into the wall. 1. R emove the front co ver of the old thermostat. 2 . With wir es still attached, remo ve wall plate from the wall by loosening the scr ews. If the old thermostat has a wall mounting plate, remo ve both the thermostat and the wall mounting plate.
O/B G W/E W2 L Y2 Y1 RC RH C C 6 T ake care when securing and routing wir es so they do not shor t to adjacent terminals or rear of ther mostat. P ersonal injury and/or property damage may occur . CA UTION STEP 2. Mount the Ne w Thermostat 1. U npack the thermostat and separate the mounting plate from the thermostat.
O/B G W/E W2 L Y2 Y1 RC RH C C 7 3. Once you have established the desir ed location of the thermostat, use a pencil, and the wall plate as a template, to mark the location of the mounting holes on your wall. 4. Mo ve wall plate out of the way and drill two holes using a 3/16" drill bit.
8 Connect wires as follows: • If necessary , strip insulation about 3/8 inch from the end of the wir e. • U se the table you previously filled out on the back of the installation manual (or the wir ing chart on page 20) to locate the corr ect terminal for each wire connection.
9 STEP 3. Configure the Thermostat 1. T o enter the INST ALLA TION MENU, simultaneously press and hold and for 3 seconds. Y ou will be greeted with the following disclaimer .
NO TE: The pr esence of a wir e in the W2 terminal is a good indication that the user has two-stage equipment located inside the house (furnace, air handler , or boiler). The pr esence of a wire in the Y2 terminal is a good indication that the homeo wner has two-stage equipment located outside the house (air conditioner or heat pump).
11 3. About This Device Installation > About This Device By properly identifying the type of equipment on pr emise in the HV AC Equipment Setup portion of the installation menu, no further modifications to the thermostat are r equired.
This feature is intended to help pr otect the compressor from short cycling. Some newer compr essors already have a time delay built in and do not requir e this feature. Y our compressor manufacturer can verify if the lockout featur e is already present in their system.
This configures whether the O/B terminal for the heat pump r eversing valve will be energized during cool (O) or heat (B) mode. 4D. O/B Configuration Installation > Advanced HV AC Options > O/B .
STEP 4. Check Thermostat Operation T o prevent compr essor and/or proper ty damage, DO NO T operate the cooling system if the outdoor temperature is belo w 55° F . CA UTION Once you have installed your new ther mostat, you need to check that the fan, cooling system, and heating system are all operating properly .
Check the heating system 1 . Pr ess Heating / Cooling Mode key one or mor e times to select HEA T mode. If the auxiliary heating system has a standing pilot, be sure to light it. 2. P ress the to adjust thermostat setting to 1° abo ve room temperature.
Check the back-up heating system (heat pump systems only): The Back U p Heat bypasses the heat pump to use the heat source wired to E & W2 terminals of the thermostat.
STEP 5. P air Device to a Home Area Network Installation > N etwork Settings > Installation I nformation F rom the NETWORK SETTINGS screen, highlight INST ALL A TION INFORMA TION and press .
Once you have pro vided the two numbers above you will be asked to send a “Join ” request from the thermostat. T o do so go to the NETWORK CONNECTION screen. STEP 3 P ress the CONNECT key . STEP 4 Y ou may have to wait up to 3 minutes for the pairing process to be completed.
STEP 6. V erify Wireless Connectivity The following scr een in the NETWORK SETTINGS area of the installation menu will serve as fur ther confirmation of network connectivity: STEP 1 On the home screen, a wir eless icon will also confirm that the unit is in fact connected to a network coordinator .
NO TE: This product requir es 24V power supply via the C terminal to operate. W iring Chart O/B G W/E W2 L Y2 Y1 RC RH C O/B G W/E W2 L Y2 Y1 RC RH C NO TE: No thermostat installation uses all of the wir es shown belo w . In most cases, between 5 and 6 terminals ar e wired.
21 Y1 Conventional H VA C Cool Mode Stage 1 Compressor Contactor Heat P ump Y2 Cool Mode Stage 2 Compressor Stage 2 W/E Heat M ode Stage 1 A UX Heat Stage 1 W2 Heat M ode Stage 2 A UX Heat Stage 2 O/B.
37-7301C W iring T able Old T erminal W , W1, 4, E W/E Y , Y1 Y1 G G R C, R R C RH, 5, R5 RH W2, W-U W2 Y2 Y2 C C L, F L O, B O/B Wir e Color N ew T erminal 2013 Emerson, Emerson Climate Technologies are trademarks of Emerson Electric Co. or one of its affiliated companies.
デバイスEmerson EE542-1Zの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Emerson EE542-1Zをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmerson EE542-1Zの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Emerson EE542-1Zの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Emerson EE542-1Zで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Emerson EE542-1Zを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmerson EE542-1Zの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Emerson EE542-1Zに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmerson EE542-1Zデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。