Page 1 19562-1-0606 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL Patent # 5.664.555 W ARNING: If not installed, operated and main- tained in accordance with the manufactur er's instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness.
Page 2 19562-1-0606 SECTION P AGE Important Safety Information .............................................................................................. 3 Safety Information for Users of LP Gas ....................................................
Page 3 19562-1-0606 • Due to high temperatures the appliance should be located out of traffic and away from furnitur e and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Page 4 19562-1-0606 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
Page 5 19562-1-0606 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residentia.
Page 6 19562-1-0606 Introduction Al w ay s c on s ul t y ou r l o ca l B u il di n g D e pa rt m en t r e ga r di ng regulations, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to Installer 1. Installer must leave instruct ion manual with owner after installation.
Page 7 19562-1-0606 Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. L.P . Nat. L.P . 0-10 feet 0-3 meters 1/2” 12.
Page 8 19562-1-0606 W arning: Conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are pr ovided in conversion kit attached to manifold pipe. 1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit.
Page 9 19562-1-0606 1. Pick a location on a wall with a clear space of 36" (91.4cm) high by 43" (109cm) wide in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearance s for servicing and proper installation .
Page 10 19562-1-0606 Installing W all Bracket (Figures 5 and 6) After finding a location for the furnace, gas supply and vent, the wall bracket must be positioned and installed. The bracket should be mounted to the wall studs, if possible, or anchored solidly to the wall.
Page 1 1 19562-1-0606 Be sure to deburr the ends with a file after cutting. Installation is easy after cutting the wall opening secure the vent terminal box in place using the (4) 10 x 1" hex-head screws provided. Locate the box so that the middle exhaust tube is directed toward the furnace exhaust outlet opening.
Page 12 19562-1-0606 Figure 1 1 Condensate Removal (Figures 1 1 and 12) The condensate drain kit is used in conjunction with DVE and DVE-2, intake/exhaust extension kits. The condensate drain kit is required whenever there is a vertical vent run, in a heated room [10 ft.
Page 13 19562-1-0606 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance does not have a pilot.
Page 14 19562-1-0606 The appliance, when installed, must be electrically grounded in ac- cordance with local codes or , in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized.
Page 15 19562-1-0606 The hot surface ignitor is energized and after a 17 second warm- up, the gas valve circuit is energized, opening the gas valve and igniting the burners. After burning for about 30 seconds, the circulating air blower comes on, delivering warm air to the room.
Page 16 19562-1-0606 FURNACE CONTROL BOARD DIAGNOSTICS F AUL T SEQUENCE CODE — TROUBLE SHOOTING GUIDE # of Blinks Fault Condition Fault Correction Steady On Control OK 1 Flash T emperature limit swi.
Page 17 19562-1-0606 INDEX P AR T NO. NUMBER DESCRIPTION INDEX P AR T NO. NUMBER DESCRIPTION 1 D V- 1 37 8 S HR OU D T O P 2 D V- 1 37 6 S HR OU D S I DE R I GH T 3 R -2 5 21 A IR FI LT E R 4 D V- 1 3.
Page 18 19562-1-0606 P AR TS VIEW.
Page 19 19562-1-0606 SER VICE NOTES.
Page 20 19562-1-0606 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
デバイスEmpire Comfort Systems DV-20E-5の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems DV-20E-5をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems DV-20E-5の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems DV-20E-5の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems DV-20E-5で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems DV-20E-5を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems DV-20E-5の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems DV-20E-5に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems DV-20E-5デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。