Empire Comfort SystemsメーカーFAW-40-1SPPの使用説明書/サービス説明書
ページ先へ移動 of 18
Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL F AN TYPE VENTED W ALL FURNACE MODEL F A W -40-1SPP F A W -40-1IP W ARNING: If not installed, operated and maintained in accordance with the .
Page 2 The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile.
Page 3 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
Page 4 furnace opening confined� space Figure 1 Outdoor Air Outlet and inlet air can be brought into the confined space via openings into a ventilated attic and ventilated crawl space.
Page 5 C. 4" (102mm) Oval In-The-W all (all parts purchase locally) 1. T ype B-1 oval pipe or B-W vent pipe 2. T ype B-1 oval elbows or B-W oval elbows 3. Single story type B-1 or (B-W) gas vents require a baseplate and one pair of ceiling plate spacers.
Page 6 Figure 5 Use U.L. listed gas vent equipment when installing the F A W -40. For vent pipe running through walls, roof, and within one (1) inch (25mm) of combustible construction, use B-1 or (B-W) [one inch (25mm) clearance to combustibles] vent pipe.
Page 7 #8 x 3/8" (9mm) screws provided. 8. Align clearance holes on 6" x 10" (152mm x 254mm) duct with screw holes on inner casing back and mark duct to be 2 1/4" (57mm) shorter than 8" x 12" (203mm x 305mm) boot. Remove duct and cut to proper length.
Page 8 Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w .c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition. Checking Manifold Pressur e Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve.
Page 9 Oiling the Motor The fan motor should be cleaned and oiled once each heating season. Oil holes are located on the top at each end of the motor . Use a few drops of #10 motor oil. T o clean the motor, blow air through its ventilation openings with a vacuum cleaner or low pressure air source.
Page 10 SER VICE AND MAINTENANCE SUGGESTIONS CALL SER VICEMAN GENERAL: All furnaces have been fire-tested to check for proper op- eration. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation.
Page 1 1 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
Page 12 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This applian ce is equipped with an ignition device which automatically lights the pilot.
Page 13 ST AR T System Check T rial for Ignition Main Burner Operation END Pilot V alve Opens Ignitor Powered Flame Signal Detected Thermostat Calls for Heat Ignitor OFF Main V alve Op.
Page 14 ST AR T IP SYSTEM TROUBLESHOOTING SEQUENCE T urn OFF Gas Supply Disconnect System Control Harness Set Thermostat to Call for Heat Check for Proper V oltage at Control Harness (See Inset A - V o l t a g e S h o u l d b e 2 4 V Between Thermostat and 24V Common, and 24V Between 24V Common and 24V Hot.
Page 15 I N D E X P A R T N O . N U M B E R D E S C R IP TI ON I N D E X P A R T N O . N U M B E R D ES CR IP TI ON PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide.
Page 16 12427-6-0707.
Page 17 Service Notes 12427-6-0707.
Page 18 Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomfort.
デバイスEmpire Comfort Systems FAW-40-1SPPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems FAW-40-1SPPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems FAW-40-1SPPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems FAW-40-1SPPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems FAW-40-1SPPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems FAW-40-1SPPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems FAW-40-1SPPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems FAW-40-1SPPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems FAW-40-1SPPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。