12428-3-0706 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL Installer: Leave these instructions with the consumer . Consumer: Retain these instructions for futur e use.
12428-3-0706 Page 2 Introduction Always consult your local Building Department regarding regu- lations or ordinances which apply to the installation of a vented wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after instal - lation.
12428-3-0706 Page 3 SAFETY INFORMA TION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fir es and explosions. In its natural state, propane is odorless and colorless. Y ou may not know all the following safety precau - tions which can protect both you and your family from an accident.
12428-3-0706 Page 4 V entilation and Combustion Air W all furnaces shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions.
12428-3-0706 Page 5 8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper length. 8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with (6) #10 x 1/2” (13mm) screws provided. 9. Insert rear register into 8” x 12” (203mm x 305mm) boot.
12428-3-0706 Page 6 4. Connect nylon cap on 3’ (914mm) plug assembly to nylon plug on the wiring harness. 5. Place 7/8” (22mm) strain relief bushing around the cord of the 3’ (914mm) plug assembly . Insert 7/8” (22mm) strain relief bushing into the 7/8” (22mm) hole in the side panel.
12428-3-0706 Page 7 T o light the pilot, it is important that the electrode be 1/8” (3mm) from the thermocouple. The spark must occur at the point the burner flame hits the thermocouple. The end of the electrode will be red hot with the pilot on. On a new installation with air in the gas line, it is suggested that a match be used.
12428-3-0706 Page 8 V ent Safety Shutoff System This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system.
12428-3-0706 Page 9 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
12428-3-0706 Page 10 Please Note: When ordering parts, it is very important that part number and description of part coincide. Index No. Part Number Description Index No.
12428-3-0706 Page 1 1.
12428-3-0706 Page 12 Model No. F A W -55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor . Clearance to combus - tible construction is held by the fixed spacers at 1 inch (25mm) with B-1 vent pipe. Installation must conform to local codes.
デバイスEmpire Comfort Systems FAW-55SPPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems FAW-55SPPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems FAW-55SPPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems FAW-55SPPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems FAW-55SPPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems FAW-55SPPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems FAW-55SPPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems FAW-55SPPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems FAW-55SPPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。