Page 1 23200-0-1206 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL The Breckenridge Deluxe V ent-Free Universal Fireboxes DO NOT A TTEMPT TO MODIFY OR AL TER THE CONSTRUCTION OF THE FIREBOX OR ITS COMPO- NENTS. ANY MODIFICA TION OR AL TERA TION OF CONSTRUCTION MA Y VOID THE W ARRANTY OF THIS FIREBOX.
23200-0-1206 Page 2 SECTION P AGE Important Safety Information ................................................................................................. 3 Introduction ...........................................................................
Page 3 23200-0-1206 The installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition) and to the National electrical Code, ANSI/NFP A70 (latest edition). NO TE: I nst al la tio n and r ep air sho ul d be done by a qua li - fied service person.
23200-0-1206 Page 4 Clearances to combustibles Sidewall Clearances: The clearance from the inside of the firebox to perpendicular combustible side wall should not be less than 6". See Figure 1. Fir ebox Side and Bac k Clearances: The firebox outer casing side and back flanges are zero clearance to combustibles.
Page 5 23200-0-1206 Deluxe V ent-Free Firebox Framing Dimensions (in inches) "A" "B" "C" Model Framing Height Framing W idth Framing Depth VFD32FB 36 1/8" 35" 1.
23200-0-1206 Page 6 Figure 7 Firebox Dimensions H J K I A G F B E H I A G F B E C D L M DELUXE LOUVERED DELUXE FLUSH FIREBOX INST ALLA TION INSTRUCTIONS (continued) DELUXE REFERENCE LETTER LOUVERED FL.
Page 7 23200-0-1206 Locating Firebox Place firebox in framing opening. Use the four (4) framing brackets provided on the firebox to attach firebox to framing. Different hole locations can be used for finishing materials with thicknesses of 3/8", 1/2" and 3/4".
23200-0-1206 Page 8 The fireb ox is desi gned to accept a 3/8- inch gas line for an appr oved vent-free gas logset. Have the line installed by a qualified service pers on in accord ance with all buil ding code s. Consul t local buil ding codes to properly size the gas supply line leading to the 3/8-inch hook-up at the unit.
Page 9 23200-0-1206 OPTIONAL FRESH AIR KIT INST ALLA TION INSTRUCTIONS FOR DELUXE AND PREMIUM FIREBOXES 4. Next, with the vise grip attached, feed the long control rod through the small rectangular opening at the left side of the firebox face.
23200-0-1206 Page 10 with the hole in the front flange of the movable air door . See Figure 18. 7. Once the control rod is fed through the air door hole, gently lift the outer air door plate assembly inward and upward until the mounting holes in the plate line up with the pilot holes in the side wrap.
Page 1 1 23200-0-1206 Completion of Air Kit installation 1. Determine the length of 4” Dia. rigid or flex duct connector (installer supplied) you will need from the firebox/fireplace to the exterior surface of the outside wall, where the air kit hood will be installed.
23200-0-1206 Page 12 OPTIONAL SINGLE SPEED BLOWER INST ALLA TION INSTRUCTIONS Attention: Install blower assembly before connecting gas inlet supply line.
Page 13 23200-0-1206 4. Insert blower assembly into interior , bottom of firebox. Posi- tion blower assembly so that you align the notch on back of blower assembly with the center screw on firebox back, then push the blower assembly against firebox back.
23200-0-1206 Page 14 Blower Motor The blower motor does not have oiling holes. Do not attempt to oil the blower motor . Blower Wheels The blower wheels will collect lint and could require periodic cleaning. If the air output decreases or the noise level increases, it indicates a dirty blower wheel.
Page 15 23200-0-1206 CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCA L, CITY AND ST A TE BUIL DING CODE S. BEFORE MAKING THE ELECTR ICAL CONNEC TION, MAKE SURE THA T MAIN POWER SUPPL Y IS DISCONNECTED.
23200-0-1206 Page 16 P AR TS LIST ITEM P ART NUMBER DESCRIPTION VFD32FB0L VFD32FB2DL VFD32FB2CL VFD32FB0F VFD32FB2DF VFD32FB2CF 1 17149 17149 17149 17149 17149 17149 TOP ST ANDOFF 2 17169 17169 17169 .
Page 17 23200-0-1206 Parts can be ordered through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number .
23200-0-1206 Page 18 P AR TS VIEW 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 1 16 17 17.
Page 19 23200-0-1206 Accessory Description Model Numbers Fan Kit 1 2 Designed to provide forced air flow . FBB5 V ariable Speed Control Kit W all mounted variable speed control for use with FBB5 blow.
23200-0-1206 Page 20 Extended 4" Hoods Extended hoods that extend out 2" farther than the standard hoods, to accommodate thicker surround materials.
デバイスEmpire Comfort Systems VFD32FB2DF-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems VFD32FB2DF-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems VFD32FB2DF-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems VFD32FB2DF-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems VFD32FB2DF-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems VFD32FB2DF-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems VFD32FB2DF-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems VFD32FB2DF-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems VFD32FB2DF-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。