Page 1 14008-0-0403 I NST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED GAS LOG HEA TER OR VENTED DECORA TIVE APPLIANCE MODELS EFFECTIVE DA TE APRIL, 2003 W ARNINGS If the information in this manual is not followed exactly , a fir e or explosion may r esult causing property damage, personal injur y or loss of life.
Page 2 14008-0-0403 Section Page Important Safety Information ................................................................................................... ...................... 3 Safety Information for Users of LP Gas .........................
Page 3 14008-0-0403 W hen used without adequate combustion and ventilation air , heater may give off CARBON MONOXIDE, an odorless, poisonous gas. Do not install heater until all necessary pr ovisions are made for combustion and ventilation air .
Page 4 14008-0-0403 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor.
Page 5 14008-0-0403 IMPOR T ANT : Read all instructions carefully before starting installation. Failure to follow these installation instructions may result in a possible fir e hazard and will void the warranty . Save this manual for futur e refer ence.
Page 6 14008-0-0403 GENERAL INFORMA TION This is an unvented gas-fired heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
Page 7 14008-0-0403 PROVISIONS FOR ADEQUA TE COMBUSTION & VENTILA TION AIR Minimum Dimensions For Solid Fuel Burning Fireplaces UL127 Factory Built Fir eplaces (Figure 2) Model A B C D VFSV -16 18.
Page 8 14008-0-0403 Sidewall & Ceiling Clearances (Figure 3) Figure 3 The sides of the fireplace opening must be 6" from any combustible wall. The ceiling must be at least 36" (for the 16" log) and 41" (for 18", 24" and 30" logs) from the fireplace opening.
Page 9 14008-0-0403 FIREPLACE PREP ARA TION • T urn off gas supply to fireplace or firebox. • Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstructions. Have this cleaning performed annually after installation.
Page 10 14008-0-0403 INST ALLING AS A VENTED APPLIANCE Notice (Damper Clamp Installation) When installing your log set as a vented installation the damper clamp must be used. When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burn- ing the logs for the first time.
Page 11 14008-0-0403 GAS SUPPL Y Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L (Feet) Inside Diameter Outside Diameter Nat.
Page 12 14008-0-0403 PLACEMENT OF GLOWING EMBERS AND LA V A ROCK Placement of the glowing embers (rock wool) is very individual and light coverage of the areas indicated will provide your best effects. W e recommend separation of the rock wool by hand and make your coverage as light and fluffy as possible.
Page 13 14008-0-0403 Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed. In normal operation at full rate after 10 to 15 minutes, the flame appearance should be sets of yellow flames.
Page 14 14008-0-0403 HI/LO REGULA TOR CONTROL KNOB PIEZO IGNIT OR FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
Page 15 14008-0-0403 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand.
Page 16 14008-0-0403 Figures 15 and 18 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet.
Page 17 14008-0-0403 Annual inspection and cleaning by your dealer or qualified service technician is recommended to pr event malfunction and/or sooting. TURN OFF HEA TER AND ALLOW T O COOL BEFORE CLEANING . Remove logs, handling carefully by holding gently at each end.
Page 18 14008-0-0403 WIRING Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing. 16", 18", 24" and 30" Gas Logs (Millivolt) thermopile is self powered gas valve and does not require 1 10 volts.
Page 19 14008-0-0403 If the gas quality is bad, your pilot may not stay lit, the burners may pr oduce soot and the heater may backfire when lit. If the gas quality or pressur e is low , contact your local gas supplier immediately . 1. When ignitor button is pressed, there is no spark at ODS/pilot.
Page 20 14008-0-0403 Index Part No. Number Description COMMON P ARTS 1 15425 REAR LOG SUPPORT (16) 1 15426 REAR LOG SUPPORT (18) 1 15427 REAR LOG SUPPORT (24) 1 15428 REAR LOG SUPPORT (30) 2 1 1285 BU.
Page 21 14008-0-0403 PAR TS VIEW Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number.
Page 22 14008-0-0403 SER VICE NOTES.
Page 23 14008-0-0403 SER VICE NOTES.
Page 24 14008-0-0403 Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomfort.
デバイスEmpire Comfort Systems VFSR-18-3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Comfort Systems VFSR-18-3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Comfort Systems VFSR-18-3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Comfort Systems VFSR-18-3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Comfort Systems VFSR-18-3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Comfort Systems VFSR-18-3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Comfort Systems VFSR-18-3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Comfort Systems VFSR-18-3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Comfort Systems VFSR-18-3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。