Installer: Leave this manual with the appli- ance. Consumer: Retain this manual for futur e refer - ence. — Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance. — WHA T TO DO IF YOU SMELL GAS • Do not try to light any appliance.
12429-10-0408 Page 2 T ABLE OF CONTENTS INTRODUCTION .................................................................................................................. 3 SAFETY INFORMA TION FOR USERS OF LP-GAS .........................................
12429-10-0408 Page 3 Introduction Al w ay s c o ns u lt y o ur lo c al Bu i ld in g D e pa r tm en t r e ga r di n g regulations, codes or ordinances which apply to the installation of a vented wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after installation.
12429-10-0408 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
12429-10-0408 Page 5 V entilation and Combustion Air W all furnaces shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions.
12429-10-0408 Page 6 Figure 2 Figure 3 Figur e 3A VENT CENTER TO COMBUSTIBLES MINIMUM CLEARANCE 9/16” (40mm) 4”(102mm) OVAL TYPE “B” CONNECTION 7/1/2” (191mm) MINIMUM CLEARANCE TOP T O COMBU.
12429-10-0408 Page 7 Locating Furnace On W all The furnace is to be located on a wall. The furnace is 16 inches (406mm) in width and normal 16 inches (406mm) on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned.
12429-10-0408 Page 8 Figure 6 Electrode and pilot must be kept clean. Clean through pilot access hole with a small brush (toothbrush) and water . Proper Main Burner Flame The correct flame will be a short blue inner flame with a much larger light blue outer flame.
12429-10-0408 Page 9 V ent Safety Shutoff System This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system.
12429-10-0408 Page 10 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition devi ce which automatically lights the pilot.
12429-10-0408 Page 1 1 CALL SER VICEMAN SER VICE AND MAINTENANCE SUGGESTIONS GENERAL: All furnaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation.
12429-10-0408 Page 12 If the pilot does not light, or the pilot flame current is not at least 1.0 uA and steady , the module will not energize the second main valve and the main burner will not light. Safety Lockout S8600H provides 100 percent shutoff, or safety lockout.
12429-10-0408 Page 13 Important 1. The following service procedures are provided as a general guide. 2. Meter readings between gas control and ignition module must be taken within the trial for ignition period. Once the ignition module locks out, the system must be reset by setting the thermostat down for at least one minute before continuing.
12429-10-0408 Page 14 S8600H TROUBLESHOOTING GUIDE.
Gr een LED Status Codes Green LED Flash Code (X + Y) a Indicates Next System Action Recommended Service Action OFF No “Call for Heat” Not applicable None Flash Fast Startup-Flame sense calibration Not applicable None Heart Beat Normal operation Not applicable None 3 Recycle - Flame failed during run Initiate new trial for ignition.
12429-10-0408 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 WF A-115 Baseplate Gasket 2 1 1763 Outer Casing T op 3 632024 Motor Mo.
12429-10-0408 Page 17 Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62222-0529 P AR TS VIEW.
12429-10-0408 Page 18 Model No. F A W -55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor . Clearance to combustible construction is held by the fixed spacers at 1 inch (25mm) with B-1 vent pipe. Installation must conform to local codes.
12429-10-0408 Page 19 SER VICE NOTES.
12429-10-0408 Page 20 EMPIRE EMPIRE Comfo r t Systems Empire Comfort Systems Inc. 918 Freeburg A ve. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer .
デバイスEmpire Products FAW-55IPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Empire Products FAW-55IPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEmpire Products FAW-55IPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Empire Products FAW-55IPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Empire Products FAW-55IPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Empire Products FAW-55IPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEmpire Products FAW-55IPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Empire Products FAW-55IPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEmpire Products FAW-55IPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。