SecureS t ack C2 Redundant Power System C2RPS-SYS Inst allation Guide C2RPS-CHAS8 C2RPS-PSM Powe r 9033977-0 1 Caution: Do not use this product with SecureS t ack C2 PoE devices.
.
i Notice Enterasys Networks reserv es the right to make changes in specifica tions and other information containe d in this document and its web site without prior notice.
ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device co mplies with Pa r t 15 of the FCC rules.
iii Electromagnetic Compatibility (EMC) This product complies with the following: 47 CF R Pa r t s 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000 ‐ 3 ‐ 2, EN 61000 ‐ 3 ‐ 3, EN 55024, AS/NZS CISPR 22, VCCI V ‐ 3.
iv Declaration of Conformity Application of Co uncil Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’s Na me: Enterasys Networks, Inc. Manufacturer ’ s Address: 50 Minuteman Road Andover, MA 01810 USA European Representativ e Address: Enterasys Networks, Ltd.
v Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT , CAREFULL Y READ THIS LICENSE AGREEMENT . This document is an agreement (“ Agreement”) betwee n the end user (“Y ou”) and Enterasys Networks, Inc.
vi 3. APPLICABLE LAW. This Agreem ent shal l be interpreted and governed under the laws and in the state and federal cour ts of the Commonwealth of Massachusetts wi thout regard to its conflicts of laws provisions.
vii 8. AUDIT RIGHTS. You here by acknowl edge that the intellectual property rights associated with the Program are of critical value .
viii.
ix Contents About this Guide Using This Guide ......... ................ ............. ................ ............. ................ ............. ............. . ................... xi Structure of This Guide ............. ................ ........
x Figures 1-1 SecureStack C2RPS-CHAS8 (front view without PSMs) ........... ............. ................ ............. .. 1-2 1-2 SecureStack C2RPS-CHAS8 (rear view with eigh t PSMs) ........... ............. ............. ............. .. 1-2 1-3 C2RPS-PSM (front view) .
SecureStack C2 Installation Guide xi About this Guide This guide prov ides an overview , installation and troubleshooting instructions, and specifications f.
Using the SecureStack C2 Manual Set xii About this Guide Using the SecureS t ack C2 Manual Set Other manuals have been develope d for the SecureStack C2 non ‐ PoE switch devices that can be connected to the RPS for power redundancy .
Conventions Used in This Guide SecureStack C2 Installation Guide xiii Conventions Used in This Guide The following conventions are used in this guide: Note: Calls the reader ’s attention to any item of information that may be of spe cial import ance.
Conventions Used in This Guid e xiv About this Guide.
SecureStack C 2 Installation Gui de 1-1 1 Introduction This chapter provides a functional overview of the Redundant Pow e r System (RPS), which incl.
RPS Overview 1-2 Introduction C2RPS-CHAS8 Chassis The chassis is a an eight ‐ slot frame with out AC power connections or electronics. The chassis can be installed in a standar d 19 ‐ inch rack and populated with up to eight PSMs.
RPS Overview SecureStack C 2 Installation Gui de 1-3 C2RPS-PSM Power Supply Module The PSM provides the following: •H o t sw ap capability . •O n e 12 Vdc, 150 Wa t t s of maximum ‐ continuous pow er output to a connected SecureStack C2 switch device.
RPS Deployment Strategies 1-4 Introduction RPS Deployment S trategies The RPS can be de ployed in a va r i e t y of situations with mission ‐ cr itical applications.
Getting Help SecureStack C 2 Installation Gui de 1-5 Getting Help For additional support related to the devices or thi s document, contact Enterasys Net.
Getting Help 1-6 Introduction.
SecureStack C 2 Installation Gui de 2-1 2 Installation This chapter provides the installation instructions to install all the components of an RPS. To correctly install an RPS, follow the order of information listed below .
Installing C2RPS-PSMs 2-2 Installation 3. P erform a visual inspection of the switch device s for any signs of physical damage. Contact Enterasys Netw orks if there are any signs of damage.
Installing C2RPS-PSMs SecureStack C 2 Installation Gui de 2-3 5. Proceed to “ Installi ng C2RPS ‐ CHAS8 into the Rack ” on page 2 ‐ 4 for the rack mount installati on instructions.
Installing C2RPS-CHAS8 into the Rack 2-4 Installation 3. Pull the PSM out and remove it from the chassis. 4. Repeat steps 1 through 3 for each additional PSM yo u plan to remove.
Installing C2RPS-CHAS8 into the Rack SecureStack C 2 Installation Gui de 2-5 •A n amb ient temperature of betw een 5 ° C (41 ° F) and 40 ° C (104 ° F) mus.
Connecting the PSM Cables and AC Power Cords 2-6 Installation Figure 2-2 Fastening the C2RPS-CHAS8 t o the Rack Connecting the PSM Cables and AC Power Cords The PSMs ar e connected to the SecureStack Ethernet switch devices using PSM cables.
Connecting the PSM Cables and AC Power Cords SecureStack C 2 Installation Gui de 2-7 5. On certain switches, an LED indicator will show that a redundant pow er supply is now in operation.
Connecting the PSM Cables and AC Power Cords 2-8 Installation Figure 2-5 C2RPS-PSM Cable and AC Power Cord Co nnections 1 Switch device 4 Switch device Redundant Powe r Supply connector 2 PSM cable 5 .
SecureStack C2 Installation Guide A -1 A Specifications This appendix provides information about the f ollowing: Enterasys Netw orks reserves the right to change the specifications at any time without notice.
C2RPS-PSM Specifications A-2 Specifications C2RPS-PSM Specifications Refer to Ta b l e A ‐ 2 for the input/outpu t port specifications .
Compliance Standards SecureStack C2 Installation Guide A -3 Compliance S t andards The C2RPS ‐ PSM meets the safety and electromagnetic compati bility (EMC) requi.
Compliance Standards A-4 Specifications.
デバイスEnterasys C2RPS-SYSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enterasys C2RPS-SYSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnterasys C2RPS-SYSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enterasys C2RPS-SYSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enterasys C2RPS-SYSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enterasys C2RPS-SYSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnterasys C2RPS-SYSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enterasys C2RPS-SYSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnterasys C2RPS-SYSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。