6H308-24 and 6H308-48 F ast Ethernet Installation Guide RESET C O M CPU FAST ENET 6H308-48 GROUP GROUP SELECT 4 1X RESET C O M CPU FAST ENET 6H308-24 1X 12X 13X 24X G R O U P 1 G R O U P 2 GROUP GROUP.
.
NOTICE Enterasys Netw ork s and its lic ensors reserv e t he right to ma ke cha nges in sp ecif ication s and ot her inform ation c ontain ed in this doc ument witho ut prior notice. Th e reader should in a ll cases consult En te rasys Netwo rks to determine whether any such change s have been made.
FCC NOTICE This de v ic e co mplies with P art 15 of the FCC rules. Ope rat ion is subject to th e follo wing two c ondit ion s : (1) t his de vice may not cause harmful i nterference, and (2) th is device must accept any interfe rence rece iv ed, includ ing int erference that may ca u se undesi re d operat ion .
ENTERASYS NETWORKS, INC. PROGRAM LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT , CAREFULL Y READ THIS LICENSE A GREEMENT . This documen t is an agreement (“ Agreement”) between Y ou, the end use r, and Enterasys Networks, Inc.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS . The enclosed Produ ct (i) w as devel oped sol ely at private expen se; (ii) contains “rest ricted computer software” submitte d with restricted rights in accordance with secti on 52.
DECLARATION OF CONFORMITY Appli ca tio n of C ou nc il Di re ct ive ( s) : 89/336 /EEC 73/23/EEC Manufacturer’s Name: Enterasys Network s, Inc. Manufactur er’ s Address: 35 Industrial Wa y PO Box 5005 Roches ter, NH 03867 European Re presentative Name: Mr.
.
Contents vii Contents Figures ......... ............. ................... ............. ................... ............. ................... ............... ..... ............... ix Tables.... .................... ............ .................... ..
viii Contents 3 INSTALLATION 3.1 Unpackin g the Modu le .......................... .................... ............ .................... ...... 3-2 3.2 Installing Op tional FLA SH Upgrade ...... .................... ............ .................... .
Figures ix Figures Figure P age 1-1 The 6H308-24 and 6 H308-48 Modu les .................. ................... ................... ............. ...... 1-2 3-1 Installing the Mod ule into th e MATRIX E 7 Chassis ................... ............. .....
x Ta b l e s Ta b l e s Ta b l e Pa g e 3-1 Contents o f Module Ca rton ....... ............. .................... ................... ............. ...................3-2 4-1 LANVIEW LEDs ........... .................... ............. ...............
About This Guide xi About This Guide W elcome to the 6H308-24 and 6H308-48 Fast Ethern et User’s Gui de . This guide descri bes the 6H308-24 an d 6H308-48 modules and provides information concerning netw ork require m ents, instal lation, and tro ubleshooting.
Stru cture of This Gu ide xii Ab out This Gui de STRUCTURE OF THIS GUIDE This gui de is orga nized as fol l ows: This chapte r pro vides preli minary inform ation to aid i n using this manual, lis ts .
Document Conv entions About This Guide xiii DOCUMENT CON VEN TIONS The guide uses the follo wing con v entions: NOTE: Calls the reader ’ s atten tion to any item of inf ormati on that may be o f specia l impo r tance . TIP: Conv eys helpful hints c oncer ning pr ocedures o r actio ns.
Getting H elp xiv Ab out This Gui de GETTING HELP F or additional support relate d to the module or a ny document s, contact Enter asys Network s using one of the followin g met hods : Before c ontact.
Introductio n 1-1 1 Intr oduction This chap ter introdu ces the 6H308-24 an d 6H308-48 Fa st Ethernet swit ching modules. The 6H308-24 module ( Fig ure 1-1 ) featur es 24 100B ASE-FX switch ed ports connect ed via 24 MT -RJ fibe r connectors.
1-2 Intr oduction Figure 1-1 The 6H308-24 a nd 6H308-48 M odu l es 48 100BASE-FX Fiber Optics Ports (100 Mbps) RESET C O M CPU F AS T ENET 6H308-48 GROUP GROUP SELECT 4 G R O U P 3 1X 12X G R O U P 1 .
Connecti vity Introducti on 1-3 1.1 CONNECTIVITY The modul e connects to Et hernet netw orks or wo rkstatio ns through the fr ont panel conne ctors. The ports are IEEE 802.3 100B ASE-FX compl iant, using MT -RJ f iber connector s for multimode fiber .
Smar tT runk 1-4 Intr oduction 1.4 Smart T runk T raditio nal 802.1D Spannin g Tr ee Bridges only a llow one ac tiv e data path be tween any two switche s; all other pa rallel data p aths are in Stan dby or Bloc king mode.
P or t/VL AN Redirec t Functions Introducti on 1-5 1.7 P OR T/VLAN REDIRECT FUN CTIONS The port redirect funct ion, also refer red to as “Po r t Mirroring,” i s a troubleshoot ing tool use d to map traf f ic from a single s ource port t o a single desti nation port wit hin the module.
Flow Control 1-6 Intr oduction 1.9 FLOW CONTR O L Flo w control i s a method of managin g the flo w of frames between two d evices. I t ensures th at a transmi tting de vice does not overwhel m a recei ving de vice with dat a.
Distr ibuted Chass is Managemen t Introducti on 1-7 1.12 DISTRIBUTED CHASSIS MANAGEMENT Install ation in the 6C107 MA TRIX E7 Ch assis From a manage m ent perspect ive, 6x3xx modules in the MA TRIX E7 chassi s can be managed separat ely by indi vidual IP addresses.
Switchi ng Option s 1-8 Intr oduction 1.14 SWITCHING OPTIONS The module provides 802.1Q switching between all of t he front panel i nterfaces. In the 802.1Q mode (the def ault mode of ope ration), the modul e f unct i ons as an 802.1D swi tch unt il VLANs are conf igured.
Network Requirem ents 2-1 2 Netw ork Requirements Before in sta llin g the mod ule, re vie w the req uirem ents an d specif icat ions ref erre d to in thi s cha pter concerni ng the follo w i ng: • Sma rtTrunk ( Section 2.1 ) • 100B ASE-FX Fib e r Optic Netw ork ( Section 2.
.
Install ation 3-1 3 Installa tion This chap ter pr o vide s the inst ru ction s to ins tall th e 6H308 -24 or 6 H308-48. A Phi lli ps scr e wdri ver is requ ired to instal l options into the module. F ollow the order of the sections list ed below t o correc tly instal l the module.
Unpacking the Module 3-2 Insta llation 3.1 UNPACKING THE MODULE Unpack the module as follo ws: 1. Open the bo x and remove the packing material protecting th e module. 2. Verify t he contents of the carto n as listed in Table 3-1 . 3. Remove t he tape se al on the non-cond uctive bag to re move the module.
Installi ng the Modu le into the MA TRIX E7 Chass is Install ation 3-3 3.3 INSTALLING THE MODULE INTO THE MA TR IX E7 CHASSIS The module c an be installe d in any of the slots that a re av ailable. T o install a module, refer to Fi gure 3- 1 and proceed as follo ws: 1.
Installi ng the Mod ule in to the MA TRIX E7 Chassi s 3-4 Insta llation Figure 3-1 Installing the Module into the MA TRIX E7 Chassis 35491_02 45 6 7 6C107 12 3 Backplane Connectors POWER OK/ REDUNDANC.
Installi ng the Mod ule in to the 6C105 Chassis Install ation 3-5 5. Examine th e module for damage. I f any damage exists, DO NOT i nstall the module.
Installi ng the Mod ule in to the 6C105 Chassis 3-6 Insta llation Figure 3-2 Installing the Module into the 6C10 5 Chassis RESET C O M CPU FAST ENET 6H308-24 1X 12X 1X 12X G R O U P 1 G R O U P 2 GROU.
Connecti ng to the Ne twork Install ation 3-7 3.5 CONNECTING TO THE NET WORK This sec tion pro vides the proced ures for conn ecting fi ber optic cable from the netw ork or other de vices t o the mod ule. F or de tails on ho w to ge t manua ls, refer to the “Re lated Doc uments” sect ion in Ab out This Guide .
Connectin g to the Networ k 3-8 Insta llation Figure 3-3 Connecting a Fiber Optic Segment to the Module 4. Veri fy that a link e xists by checki ng that the port RX (Recei ve) LED is ON (flashing amber, blinki ng green, or soli d green).
Complet ing the Inst allatio n Install ation 3-9 c. Verify that t he fiber connect ion meets the dB l oss and cable spec ification s for multimode cabli n g, as out lined in the Cabling Guide . If a link is not est ablis hed , see Chapter 4 b efo re co nta cting Ente rasy s Ne twork s.
.
T roubleshooting 4- 1 4 T r oubleshooting This chap ter pro vides informati on concerning the followi ng: •U s i n g L A N V I E W ( Section 4.1 ) • T rouble shooting Checklis t ( Secti o n 4.
Using LANVIEW 4-2 T roublesh ooting Ta b l e 4 - 1 describes th e LED indicati ons and pro vides rec omm ended ac tions as appr opriate. NOT E: The ter ms flashing , blinking , and solid used in Ta b l e 4 - 1 indic ate the following: Flashing indica tes an LE D is flashi ng randomly .
Using LA NVIEW T roublesh ooting 4-3 RX (Recei ve) Of f No link . No acti vity or po rt in standb y . Por t enabled or disabl ed. Non e. Green Soli d . Link, port ena bled, no ac tivity . Non e. Blinking . Link , port disabl ed. None. Amber Flashing .
Using LANVIEW 4-4 T roublesh ooting TX (T ransmit) Of f Port ena bled, and no activity . If ST A is enabl ed a nd th ere i s a v alid lin k, thi s led shoul d flash green e very tw o seconds indicating that BPDUs are be ing sent. Ensure tha t the ST A is enabled and that there is a val id link.
T roublesh ooting Che cklist T roublesh ooting 4-5 4.2 T ROUBLESHOOTING CHECKLIST If the module is not w orking pr operly , refer to Ta b l e 4 - 2 for a ch ecklist of pro blems, possibl e causes, a nd recommended ac tions to resolv e the pro blem. T able 4-2 T roubleshooting Chec klist Problem P ossible Cause Recommended Action All LEDs ar e OFF .
T roubleshooting C hecklist 4-6 T roublesh ooting Cannot con tact the mo du le through in- ban d management. IP add ress not ass igned. Refer to the MA TRIX E7 Seri es and SmartSwit ch 6000 Ser ies Modules Local Manag ement User’ s Gu ide for the I P address assignmen t procedure.
Using the RE SET Button T roublesh ooting 4-7 4.3 USING THE RESET BUTTO N The RESET b utton sho wn in Figure 4- 2 resets a nd re-initial izes the modul e. Figure 4-2 RESET Button T o reset the module processor , press and release the RESET butt on. The module goes through a reset p rocess for appr oximately 60 seconds.
.
Specif icatio ns A-1 A Spe cifi cations This appe ndix prov ides operating s pecific ations for t he Enterasys Netw orks 6H308-24 and 6H308-48 mo dules. Enter asys Net w orks re serv e s the ri ght to ch ange the spec if ic ations at a ny t ime without notice.
Fiber Budget A-2 Specif ications A.2 FIBER B UDGET When using f iber optic cables, it is important t o consider the c able type and the associated dB bud g et s sh ow n i n Ta b l e A - 2 . Ph ysical Dimensions 7.11H x 4 3.18W x 46.99D (cm) 2.8H x 17 W x 18.
COM P or t Pino ut Assignme nts Specifi catio ns A-3 A.3 COM P ORT PINOUT ASSIGNMENTS The COM port is a serial co mmunica tions port that suppor ts Local Man agement or connectio n to a UPS. Refer to Ta b l e A - 3 for the COM por t pin assignment s. A.
.
Mode Swi tch Bank Settings and Opti ons B-1 B Mode Switch Bank Settings an d Options This appe ndix cov ers the foll owing i tems: • Requi red tools ( Se ction B.1 ) • Locatio ns, functions , and settings f or the mode swit ches ( Section B.2 ) • Upgrading the FLASH ( Se ction B .
Setting th e Mode Switches B-2 Mode Swi tch Bank Settings and Opti ons B.2 SETTING THE MODE SW ITCHES Figure B- 1 shows the location of the mode switches a nd the switch settings for n ormal operation. These swi tches are se t at the fac t ory and rarely need to be changed.
Setting th e Mode Switches Mode S witch B ank Sett ings and Options B-3 • Switch 6 – Forced BootP . DO NOT attemp t a Forced Boo tP unless a BootP se rver has been c onfigured for th e module. The BootP ser ver references the location of a station act ing as a Trivial File Transfer Protocol (TFTP) ser ver containing the module image file.
FLASH Upgrade B-4 Mode Swi tch Bank Settings and Opti ons B.3 FLASH UPGRADE FLASH upgr ade is a vailabl e for the SmartSwi tch to expa nd from 8 to 16 MB . This section exp lains ho w to locate and add/repla ce the FLASH modul e. For details, refer to “ Getti ng He lp” in About This Guide .
FLASH Upgrade Mode S witch B ank Sett ings and Options B-5 B.3.2 Installing the FLASH Module T o install a FLASH module, r efer to Figure B-3 and p roceed as fol l ows: 1. With the F LASH module oriente d as shown in Figure B-3 , in sert the FLASH module d own between t he connector.
.
Index-1 Inde x Numerics 100BASE-TX requirem ents 2-1 802.1 p Port Prio rity introduction to 1-6 A Auto-Negot iation 1-3 B Broadc ast Su ppressi on introduction to 1-4 C Cable specifications 100BASE- T.
Index-2 R Receive LEDs viewing of 4-1 Redirect fu nctions port and VLAN introduction to 1-5 Regulator y Compliance A-3 Relat e d manua ls xii Remote Monitoring (RMON ) introduction to 1-4 RESET b utto.
デバイスEnterasys Networks 6H308-48の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enterasys Networks 6H308-48をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnterasys Networks 6H308-48の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enterasys Networks 6H308-48の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enterasys Networks 6H308-48で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enterasys Networks 6H308-48を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnterasys Networks 6H308-48の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enterasys Networks 6H308-48に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnterasys Networks 6H308-48デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。