9033630 V ERTICAL HORIZON VH-4802 F AST ETHERNET SWITCH USER GUIDE ELS100-48tx2m.book Page -i Thursday, Novem ber 16, 2000 4:59 PM.
ELS100-48tx2m.book Page 0 Thursday, Novem ber 16, 2000 4:59 PM.
Notice 9033630 i NOTICE Enterasys Networks reserves the right to make changes in specifications and other information contained in this document without prior notic e. The reader should in all c ases consult Enterasys Networks to determine whether any such changes hav e been made.
Notice ii 9033630 FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful int erference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Notice 9033630 iii • 21 CFR 1040.10 and 1040 .11 U.S. Department of Health and Human Services ( FD A). • IEC Publication 825 (I nternational Electrotechnical Commission). • CENELEC EN 6082 5 (European Committee fo r Electrotechnical Standardization) .
Notice iv 9033630 SAFETY INFORMATION WICHTIGE SICHERHEITSHINWEISE (GERMANY) 1. Bitte lesen Sie diese Hi nweise sorgf ä ltig durch. 2. Heben Sie diese Anleitung f ü r den sp ä teren Gebrauch auf. 3. V or jedem Reinigen ist das Ger ä t vom Stromnetz zu tr ennen.
Notice 9033630 v ENTERASYS NETWORKS, INC. PROGRAM LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENC LOSED PR ODUCT , CAREFULL Y READ THIS LICENSE A GREEMENT . This document is an agreement ( “ Agreement ” ) between Y ou, the en d user , and Enterasys Networ ks, Inc.
Notice vi 9033630 5. UNITED ST A TES GO VERNMENT RESTRI CTED RIGHTS . The enclosed Product (i) was dev eloped solely at priv ate expense; (ii) contains “ restricted computer software ” submitted with restricted rights in accordance with section 52.
Notice 9033630 vii DECLARATION OF CONFORMITY Application of Council Directi ve(s): 89/336/EEC 73/23/EEC Manufacturer ’ s N ame: Enterasys Networks, I nc. Manufactu rer ’ s Ad dress: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representati ve Name: Mr.
Notice viii 9033630 ELS100-48tx2m.book Page viii Thursday, November 16, 2000 4:59 PM.
9033630 Table of Contents ix TABLE OF CONTENTS PREFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . XI Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
x Table of Contents VH-4802 Remote Management via the Console Port . . . . . . . . . . . . . . . . . 22 In-Band Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Powering the Switch . . . . . . . . . . . . . . . . . . .
9033630 Preface xi PREFACE Purpose This guide provi des information about the fe atures and application s of the Enterasys Networks Vertical Horizon VH-4802 switch system.
xii Preface VH-4802 Other Conventions This guide u ses the following typographical convention s: • Initial Caps Menu titles and console menu selections. • [Enter] Used to designate the Enter or Return key. • courier font Screen messages and user prompts.
9033630 Product Overview 1 1. PRODUCT OVERVIEW This chapter provid es the following information: • Product Description • Features • Front and Rear Panel Compon ent Descriptions • Feature Summaries • Application Example Description This installatio n guide describes Enterasys Networks’ Vertical Hori zon VH-4802 Fast Ethernet switch.
2 Product Overview VH-4802 The VH-4802 switch is desktop or rack-mountable. LEDs on the front panel provide information about the opera ting status of the switch. The rear panel contains the power connector, redundan t power connector, serial console port, and two slots for the optional module s.
9033630 Product Overview 3 • Network Management: - SNMP compliant agent: MIB II (RFC 1213); Bridge MIB (RFC 1493); Ethernet-like MIB (RFC 1643); RMON - Statistics, History, Alarm and Event groups (RFC 1757); Interface Evolution MIB (RFC 1573); Q-MIB (IEEE 802.
4 Product Overview VH-4802 Front Panel Figure 1-1 shows the front panel of the Enterasys Networks Vertical Horizon VH-4802 . Table 1-1 defines th e VH-4802 front pan el components. Figure 1-1. VH-4802 Front Panel Table 1-1. Front Panel Compo nents Name Function Power LED Lights steady green to indicate power is supplied to th e switch.
9033630 Product Overview 5 Optional Modules Figure 1-2 shows the optional modules available for the Enterasys Networks Vertical Horizon VH-4802. Ta ble 1-2 defines the optional module components.
6 Product Overview VH-4802 Rear Panel Figure 1-3 shows the VH-4802 rear panel and Table 1-3 de fines the rear panel components. Figure 1-3. VH-4802 Rear Panel Table 1-3. Rear Panel Components Name Function Power Connector Provides AC power to the switch.
9033630 Product Overview 7 Feature Summaries The following summaries describ e VH-4802 features in areas such as standards complian ce, functionality, perfo rmance, and options. IEEE 802.1D Bridge The VH-4802 switch is fully compliant with IEEE 802.1D transparent bridging specification s.
8 Product Overview VH-4802 Software Download The VH-4802 switch supports the industry-standard Trivial File Tra nsfer Protocol (TFTP) for downloading software to the switch. All switch software is stored in a 2 MB sectored flash ROM. The download feature allows you to easily install software upgrade s to the unit.
9033630 Product Overview 9 • SNMP-based netw ork manager, in-band The system can also be managed using SNMP, the most common protocol used today for network man agement. Standard agent MIBs embedded in the switch provide basi c SNMP management thro ugh industry-standard SNMP applicatio ns.
10 Product Overview VH-4802 Auto-neg otiation Auto-negotiation is a process that permits the switch to automatically select the operational modes of its 10/100 RJ-45 ports.
9033630 Product Overview 11 Flow Control Flow control allows you to manage network traffic during congestion periods and to prevent the loss of packets when port buffer thresholds are exceeded. Flow control also serves to deny access to additional traffic that could add to a congestion condition.
12 Product Overview VH-4802 Factory Defaults Table 1-4 lists the defaul t settings for switch configuration parameters. Each parameter can be changed via the consol e menus or Telnet.
9033630 Product Overview 13 Virtual LANs Acceptable VLAN Fra me Type All Configurable PVID Tagging Yes GVRP Disabled Untagged VLAN Group Assignment 1 VLAN Ingress Filtering False VLAN Learning SVL Parameter Default Value ELS100-48tx2m.
14 Product Overview VH-4802 Application Examples The exploding pop ularity of the Internet and of corporate intranets, as we ll as new, high-band width desktop applications, are d riving the demand for Fast Ethernet.
9033630 Product Overview 15 Client/Server Network Applicat ion To improve workstation per formance in a clien t/server environm ent, the VH-4802 switch can be configu red to provide 200 Mbps ful l duplex Fast Ethernet connections to servers by connecting each to a dedicated switch port (Figure 1-4).
16 Product Overview VH-4802 Local Backbone Application The VH-4802 switch can be used in a local backbone app lication, connecting network segmen ts together and providing file-server access (Figure 1-5). Workgroup hubs are provided with a single connectio n to the switch while serve rs are put on dedicated 1 00 Mbps ports.
9033630 Installation 1 7 2. INSTALLATION Inspecting Your Shipment When you receive the shipment of your switch, check the package contents and make sure you have the following items: • VH-4802 switc.
18 Instal lation VH-4802 • Environmen tal Install the VH-4802 switch in a dry area, with adequate air circulation. Avoid placing the switch in direct sunl ight or near other heat sources, such as hot-air vents. For temperature and humidity specifications, see Appendix A, “Technical Specifications.
9033630 Installation 1 9 Mounting the Switch in a Rack The switch ships with two (2) multi-position mounting ears and four (4) mounting screws. Figure 2-1 shows the orientation of the mo unting ears for attaching the ears to the switch for a rack mou nt application.
20 Instal lation VH-4802 Installing an Optional Module into the Switch Optional module s are available for media expan sion. These modules can be installed into either of the two modular slots on the rear pa nel of the switch. To install an optio nal module into the switch, do the followi ng: 1.
9033630 Installation 2 1 Connecting a Terminal to the Console Port The console port is a serial RS-232 interface port that enables a connection to a terminal for perfo rming switch monitoring and configuration functions.
22 Instal lation VH-4802 3. Connect the other en d of the interface cable to a terminal (in some instances, an adapter may be required to make this connection).
9033630 Installation 2 3 Powering the Switch To supply power to the swi tch, connect the power cord to the switch and to a ground ed three-prong wall outlet (Figur e 2-4). See Append ix A, “Technical Specification s” on page 27 for more information regarding specific international power cord requiremen ts.
24 Instal lation VH-4802 Network Cable Requirements Copper Figure 2-1 specifi es the cable types and length constrai nts for the various copper interfaces o n the VH -4802.
9033630 Installation 2 5 Figure 2-4 specifies the fiber types, bandwidth requirements, and len gth constraints for the Gigabit Ethernet long-wa velength fiber interface on the fiber optic media module. Table 2-4. 1 000Base-LX Fiber Specifications 10Base-T/100Base-TX Ports The 10Base-T/100Bas e-TX ports use RJ-45 connectors.
26 Instal lation VH-4802 100Base-FX/1000Base-SX/LX Fiber Ports The 100Base-FX an d 1000Base-SX/LX fiber ports use SC connectors. Figure 2-6 shows an SC fiber conne ctor being in serted into a fiber port on the VH-4802.
9033630 Technical Specifications 27 APPENDIX A. TECHNICAL SPECIFICATIONS General Standards Compliance IEEE 802.1D Transparent Bridging Specifications (ISO/IEC 10038) IEEE 802.1p Traffic Class Expediting and Dynami c Multicast Filtering IEEE 802.1Q Virtual Bridged Local Area Networks IEEE 802.
28 Technical Sp ecifications VH-4802 Electrical Specifications Input voltage: 100-240 VAC Input frequency: 50-60 Hz Maximum power consumption: 90 VA Physical Specifications Height: 3.3 in. (8.4 cm) Length: 13.8 in. (35 cm) Width: 17.3 in. (44 cm mountable in a standard 19 in.
9033630 Technical Specifications 29 Port Specifications Console Port Table A-1 shows the console port pin assignments. Table A-1. RS-232 Console Port Pin Assig nments 10Base-T and 10 0Base-TX Ports Table A-2 shows the 10Base-T/100Base-T X pinouts. These ports are wired MDI-X.
30 Technical Sp ecifications VH-4802 MDI/MDI-X Crossover Cable Wiring Figure A-1 shows the wiring scheme for implemen ting a crossover cable if needed for connection to the switch’s 10Base -T or 100Base-TX ports. Such a cable may be required when connecting the switch to another switch or a hub device.
9033630 Technical Specifications 31 Country-Sp ecific Req uirements Table A-3 lists the power cord set requ irements by country and identifies the accredited agency within that country. Table A-3. Power Cord Set Requiremen ts by Country Note 1 Flexible cord mu st be <HAR> Type HO5VV-F or HO3VV-F, 3-conductor, 1.
32 Technical Sp ecifications VH-4802 Note 2 Flexible cord must be Type SV, SJ, SPT or equivalent, No. 18 AWG, 3-conductor. Wall plug mu st be a two-pole grounding type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A 250V) configuration.
9033630 Flow Control 33 APPENDIX B. FLOW CONTROL Flow control is a mechanism which allows you to protect the switch from overload conditions and to keep addi tional traffic off the network when excessive congestion will result. Figure B-1 il lustrates flow control for b oth half- and full-duplex appl ications.
34 Flow Control VH-4802 ELS100-48tx2m.book Page 34 Thursday, November 16, 2000 4:59 PM.
9033630 Acronyms & Abbreviation s 35 APPENDIX C. ACRONYMS & ABBREVIATIONS Term Definit ion 10Base-T 10 Mbps twisted-pair Ethernet 100Base-TX 100 Mbps twisted-p air Fast Ethernet 100Base-FX 100.
36 Acronyms & Abbreviat ions VH-4802 SNMP Simple Network Management Protocol TCP/IP Transmission Control Protocol/Internet Protocol TFTP Trivial File Transfer Protoco l TXD Transmit Data UTP Unshielded Twisted Pair VLAN Virtual LAN Term Definit ion ELS100-48tx2m.
9033630 Index 1 INDEX 1000Base-LX cables, 25 module defined, 5 1000Base-SX cables, 24 module defined, 5 100Base-FX modules defined, 5 10Base-T/100Base-TX ports, 25 802.
2 Index VH-4802 I IEEE 802.1D, 7 IEEE 802.1p, 11 IEEE 802.1Q, 3, 11 IEEE 802.3, 25 IEEE 802.3x, 11, 33 in-band configuration, 8 in-band connection, 22 indicators, LED, 3 inspecting your shipment, 17 i.
9033520 Index 3 serial port connecting to, 21 out-of-band management, 8 pin assignments, 29 short-wavelength fiber interface, 24 single-mode fiber, 24, 26 site requirements, 17 slots for modules, 6 SN.
4 Index VH-4802 ELS100-48tx2m.book Page 4 Thursday, Novem ber 16, 2000 4:59 PM.
ELS100-48tx2m.book Page 1 Thursday, Novem ber 16, 2000 4:59 PM.
150420-102 R01 ELS100-48tx2m.book Page 2 Thursday, Novem ber 16, 2000 4:59 PM.
デバイスEnterasys VH-4802の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enterasys VH-4802をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnterasys VH-4802の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enterasys VH-4802の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enterasys VH-4802で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enterasys VH-4802を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnterasys VH-4802の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enterasys VH-4802に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnterasys VH-4802デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。