PELLET ST OVE Ev olution PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area.
2 Safety Warnings & Recommendations..................................................................................... ..........3 Installation......................................................................................................
3 Safety W arnings & R ecommend a tions * This manual is designed for the technician in conjunction with the owner’s manual. * Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
4 Safety W arnings & R ecommend a tions CLEANING: There will be some build up of fly ash and small amounts of creosote in the exhaust. This will v ary due to the ash content of the f uel used and the oper ation of the stove. It is advisable to inspect and clean the exhaust vent semi- annually or every two tons of pellets.
5 Safety W arnings & R ecommend a tions FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “ Air Tight Homes” or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly .
Remove the two (2) wood screws (one on either side of the unit) to remove the unit from the pallet. Inst alla tion R ATING L ABEL L OCATION : The rating label is located on the inside of the ash pan co ver . D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1.
Inst alla tion D IMENSIONS : 7 IMPOR T ANT : When not installing the optional Hearth Pad on the unit, the minimum requirements for protection on combustibles floors are a width of 620mm (24”) & depth of 670mm (26”) under the unit.
Inst alla tion C LEARANCES TO C OMBUSTIBLES : This unit can be installed on a combustible floor when installed with the optional hearth pad part 50-1568 (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability .
9 Inst alla tion H EARTH P AD P EDESTAL I NSTALLATION : This unit can be installed on a combustible floor (e.g. linoleum, hardwood flooring) when the Optional Hearth Pad is installed. If this unit is to be installed onto a carpeted surf ace, a solid pad must be used underneath the Optional Hearth P ad for stability .
10 hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust above the inlet elev ation.
Inst alla tion O UTSIDE F RESH -A IR C ONNECTION : This Heater must have adequate air for proper combustion in the room that it is installed. Figure 7: Outside Air Connection.
Figure 10: Corner Installation. Inst alla tion M OBILE H OME I NSTALLATION : 4" (10 cm) 4" (10 cm) Fresh Air Intake W all thimble manufactured by pellet vent manufacturer .
13 .
.
15 2 ft (61 cm) Rain Cap (ensure cap is at least 3ft (91cm) above the roof at the lowest point) Roof Flashing Roof Rafter Fire Stop with Support Collar Ceiling Joist V ertical V ent Pipe Clean Out T ee with Pipe Adapter EF 5 NOTE: All vent sections must maintain 3 inches (7.
H EARTH M OUNT I NSTALLATION : EF 5 Existing Fireplace Clean Out T ee Fireplace Damper Location Rain Cap Seal Plate V ent Pipe (single wall stainless flex pipe or PL vent) Existing Masonary Flue Flexi.
17 Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER : The Evolution can be equipped with an externally mounted exhaust blower . This optional kit includes all components necessary to install the exhaust blower on any vertical w all surface. 1. Remov e the left hand cabinet side by removing the two (2) screws down the front.
Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : Electrical Cable EF 5 90° Elbow 45°Elbow with Rodent screen or stainless steel terminat.
19 EF5 Roof Sheathing Rain Cap Roof Flashing Roof Rafters Ceiling Joists V ent Pipe Exterior W all Sheathing Outside V ent T ermination Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - V ERTICAL T ERMINATION : F ollow the previous pages for through wall instal lations.
Inst alla tion T HERMOSTAT I NSTALLATION : 1. Install the wall thermostat (12 or 24 V olt rated) in a location that is not to close too the unit but will effectively heat the desir ed area. 2. Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat.
21 Inst alla tion S LIDER /D AMPER S ET -U P : This is used to regulate the airflow through the pellet stove. The slider damper should be set by a trained technician using magnehelic.
T roubleshooting DO NOT: ● Service the stove with wet hands. The sto ve is an electrical appliance, which ma y pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication.
23 T roubleshooting ü P oor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust T emperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now operates properly , the unit may require cleaning or a new sensor .
T roubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the fan button; does the fan come on? Press again to verify that the blower turns on; if , not contact your local dealer for service.
25 W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey Grey Gr.
P ar ts List Reference # Description Part # 1 120°F (49°C) Ceramic F an T emperatur e Sensor EC-001 Window Channel T ape - 1.8m (72”) EC-058 2 Auger Motor - 220V EF-001-220V Combustion Blower Moun.
27 P ar ts List Reference # Description Part # Door Gasket - 7ft (213 m) 50-088 23 T op Louver Set - Nickel 50-097 24 Ash Shelf Louver 50-162 Slider Damper Rod & Knob 50-293 T op Glass Retainer 50.
P ar ts Diagr am - Components EVOLUTION - Components May 2007 28.
29 P ar ts Diagr am - Steel .
30 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE.
デバイスEnviro 50-1574の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro 50-1574をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro 50-1574の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro 50-1574の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro 50-1574で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro 50-1574を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro 50-1574の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro 50-1574に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro 50-1574デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。