EnviroメーカーC-10135の使用説明書/サービス説明書
ページ先へ移動 of 38
PELLET ST OVE MERIDIAN PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area.
T able of Contents 2 Introduction..............................................................................................................3 P ellet Quality ..........................................................................................
PELLET QUALITY IS IMPORTANT, PLEASE READ YOUR ENVIRO PELLET STOVE HAS BEEN DESIGNED TO BURN WOOD PELLETS ONLY. DO NOT USE ANY OTHER TYPE OF FUEL, AS THIS WILL VOID ANY WARRANTIES STATED IN THIS MANUAL. CAUTION: It is important to select and use only pellets that are dry and free of dirt or any impurities such as high salt content.
Fuel : T his pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the oper ation and performance of the unit and may void the warranty . Check with your dealer for fuel r ecommendations.
Glass: Do not abuse the glass by striking or slamming the door . Do not attempt to oper ate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO dealer . Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot.
Y our pellet Stove has the following safety f eatures: A) The stove will shut off when the fir e goes out and the exhaust temperature drops below 120°F (49°C).
7 This stove can be placed into two different thermostat modes: HI / LOW OPERATION: If the unit has been placed in the HI / LOW mode. The unit will operate on the low setting when the thermostat is not calling for heat.
8 Oper a ting Instructions S LIDER /D AMPER S ETTING : The slider damper is located behind the left cab side. The door must be open f or the cab side to be r emoved on all models. On freestanding model loosen the two T20 torx screws, one above and one below hinge, swing open left panel to access.
PRE-BURN INSTRUCTIONS : The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper oper ation. Check the hopper for enough pellets to start the unit. DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN AJAR MANUAL MODE: To START: Press the ON / OFF Button.
10 2-3 DA YS/WEEKL Y SEASON or 2 T ONS OF FUEL Burn Pot and Liner Exhaust V ent Ash Pan Fresh air Intake T ube Inside Firebox Blower Mechanisms Door Glass Heat exchanger tubes Heat exchanger tubes Beh.
HEAT EXCHANGER TUBES (weekly) Open the door and the rod is located under the unit top, in the center of the stove just behind the door (see figure to left). This handle is to be pushed in and out a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes.
1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage, or any unventilated space. Combustion air may be obtained from a ventilated cr awlspace.
13 Inst alla tion F REESTANDING D IMENSIONS : WIDTH: 24 inches (63.2 cm) HEIGHT: 32 inches (82.6 cm) DEPTH: 24 inches (63.2 cm) Y our MERIDIAN pellet stove requires floor protection.
14 Inst alla tion I NSERT C LEARANCES TO C OMBUSTIBLES (I NSTALLED I N M ASONRY F IREPLACE ): The fireplace insert model includes a surround faceplate and a pedestal. When instal ling this unit, ensure that the pedestal is removed fr om the inside of the hopper and installed on the bottom of the unit.
1. Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, at tic, crawlspace, narrow walkway , closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, cover ed breezeway , etc.
Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. When connecting to an outside fresh air source, do not use plastic, combustible pipe. Only 2” ID (inside diameter) steel, aluminum or copper pipe should be used.
17 The MERIDIAN can be vented through the wall using two different methods. Only use vent of (L or PL) type with an inside diameter of 3 or 4 inches (7 .
Inst alla tion T HROUGH W ALL W ITH V ERTICAL R ISE I NSTALLATIONS : Wall framing Wall thimble Termination cap Vent pipe Horizontal frame for thimble Wall f.
19 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Y our P ellet Appliance. 2. Place the unit on the hearth pad (i f installed on a carpeted surface) and space the unit in a manner so when the pellet vent is installed vertically , it will be 3” (7 .
1. Lock fireplace damper in the open position. 2. Install positive flue connector at the fireplace dampers. 3. Connect a T ee or a 90 ° degree elbow to the exhaust pipe. 4. Install flexible stainless steel liner or listed pellet vent to the top of the chimney .
The MERIDIAN can be equipped with an externally mounted exhaust blower (P ART #20-070). This optional kit will include all components necessary to install the exhaust blower on any external vertical w all surface.
22 Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER : TO SUPPLY POWER TO THE EXHAUST BLOWER: Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar .
Follow the previous pages for through wall installations. Ensure that vent pipe is properly secured to wall using w all straps. Maintain clear ances to combustibles on vent pipe as well as unit.
24 Inst alla tion M ASONRY F IREPLACE I NSERT I NSTALLATION : The Fireplace insert model requires a surround faceplate and a pedestal. When installing this unit, ensure that the pedestal is removed fr.
Thread hex nut onto the bolt till it is approximately 1” (2.5cm) from the bolt head, slide washer onto bolt. Thread the bolt into the square nut so length of the bolt shown is the approximately height needed for leveling. When the unit is up right and the bolts can be adjusted to the exact height required.
26 Inst alla tion A SSEMBLY AND I NSTALLATION OF I NSERT S URROUND P ANELS : T o assemble the surround panels, lay the panels face down on a soft flat surface and align the outer edges of the sides with the top panel. Using four T20 screws up through the side panels into the top (see top left figure).
27 Inst alla tion P LATED T RIM I NSTALLATION : TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE TRIMS WHEN PELLET STOVE IS HOT! KIT COMPONENTS: T OOLS REQUIRED: ●T20 screwdriver ● 11 / 32 ” socket REMOV AL OF SIDE TRIMS: When stove is off and cool, open the door .
TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE COVER WHEN PELLET STOVE IS HOT! TOOLS REQUIRED: ● 11 / 32 ” socket or wrench REMOV AL OF DOOR COVER: When stove is off and cool, open the door . Remo ve the four #8 hex nuts around the inside of the glass retainer shown in Figure 1.
29 DO NOT: ● Service the stove wi th wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication.
30 ü Check the Exhaust Blower voltage across the blower wires (>=114V on #5 setting and >= 82V on #1 setting). – Replace the Circuit Board if the V oltage reading is less than 82V .
31 Auger light flashes but auger motor does not turn at all : ü If the Auger gear box does not turn but the motor ’ s armature does try to spin then the auger is jammed.
32 W iring Diagr am.
33 P ar ts List Part Number Description 20-040 Control P anel Door 50-178 Circuit Board 115V 50-179 Circuit Board Decal - 115V 50-323 Control P anel T ouch Latch 50-330 Circuit Board Control P anel 50.
34 MERIDIAN Steel Parts based on Freestanding Hopper lid handle 50-523 Freestanding back grill 50-675 Top trim Painted 50-671 Gold 50-672 Pewter 50-673 Antique coppe.
35 P ar ts Diagr am - Inser t Steel MERIDIAN Steel Parts based on Insert Top trim Painted 50-671 Gold 50-672 Pewter 50-673 Antique copper 50-674 Insert hopper lid 50.
36 MERIDIAN COMPONENTS 200°F (93°C) manual reset high limit sensor EF-016 Convection blower - 115V EF-002 Circuit board - 115V 50-178 Auger EF-025 Brass auger bush.
Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-year warr anty is provided on all electrical components.
38 The following information must be r ecorded by the installer for warrant y purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________.
デバイスEnviro C-10135の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro C-10135をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro C-10135の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro C-10135の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro C-10135で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro C-10135を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro C-10135の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro C-10135に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro C-10135デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。