SHERWOOD INDUSTRIES IS AN ENVI RONMENTALLY RESPO NSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 40 B Vented By SHERWOOD INDUSTRIES LTD. OWNERS MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be do ne by a qualified service person. The appliance should be inspected before u se and at once least annually by a qualified service person.
3 TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate y our stove 4 Venting 6 Installation of Log Sets and Embers 8 Operating Instructions 9 Maintenance and Technica l 10 .
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: FIG. 1 Front Width: 25"/ 63 cm Rear Width: 25"/ 63 cm Height: 29"/ 74 cm* Depth 21"/ 53 cm ( *not including vent coupling ) Shipping Weight: 256 lbs/116 kg CLEARANCES: A. Side wall to stove 12"/ 30cm B.
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or [balcony (*12 inches (30cm ) minimum] B= Clearance to window or door that ma y be opened [*12 inches (30cm) minimu m] C= Cl.
VENTING This model must have a vent opening in the r ear of the unit. C onfirm this and als o check that the label on the right side pa nel door states "Vented Room Heater". WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AI R FROM THE ROOM.
A. USING AN EXISTING CHIMNEY • Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over stretch a flexible liner to accommodate the height of the chimney. • Any flue damper must be removed or locked perman ently in the open position.
INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBE RS A bag of ceramic fiber embers is provide d for use on the front burner ember tray. CAUTION: Use only the type of ember material supp lied wi th this appliance. Due to the irregular size of the ember material there may be more than requi red.
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATIN G WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCT IONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This applianc e is equipped with a pilot, which must be lit by hand by following these instructions exactly.
MAINTENANCE AND TECHNICAL Annually check to ensure that your Vent system is clear. Periodically check the pilot and burner. Che ck to see that all the burner port s are clean and clear. Check the pilot head for blockag e. Check to ensure the pilot flame is blue with small yellow tips.
TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of sp ark igniter Defective piezo igniter Check connection s to igniter -If igniter connections .
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS FRONT BURNER #48 (1.93mm) #55 (1.32mm) REAR BURNER #41 (2.49 mm) #54 (1.40 mm) Manifold pressure. 3.8” wc (.95 kPa) 11” wc (2.74 kPa) Min. Manifold pressure. 1.1” wc (.
ELECTRICAL The ENVIROGAS EG 40.FS.BV. will operate with no external po wer supply. These models have a Milli volt gas control which uses the pilot flame to generate enoug h electricity to operate the main burner.
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve P.
• There is a separate air shutter for each burner. • Remove one screw from the cover pl ate located below the ash shelf. Loosen the other scre w (do not remove) swing the cover plate out of the way and tighten screw do wn to hold it in place. • With along screwdriver rotate spring clips to open or close the shutter to the desired setting.
16 WARRANTY Sherwood Industries Ltd. offers a *Lifetime Wa rranty on this gas produc t. The lifetime warranty covers the appliance for a period of seven years fro m the date of installation.
17 PARTS LIST EC-001 120 ° F CERAMIC TEMP SENSOR EG40-081 UPPER GOLD BARS (SET of 2) EC-003 300 ° F CERAMIC SPILL SWITCH EG40-084 FS LOWER GOLD BAR EC-006 S.
18 EG 40 DOOR AND BURNER ASSEMBLIES EXPLODED Page 1 of 2 JULY 2001 GLASS EXTRUSIONS DOOR LATCH STRIP HINGE SET OF 2 EG40-302 PAINTED DOOR ASSEMBLY WITH GLASS (A + B) EG40-073 GOLD DOOR ASSEMBLY WITH G.
19 FS UPPER BAR SET EG40-081 EG 40 FREESTANDING BODY (chassis) EXPLODED. Page 2 of 2 JULY 2001 EG 40 EMBLEM FS PEDESTAL DOOR EG40-135 FS ASH SILL EG40-213 FS LOWER BAR EG40-084 CONVECTION AIR DEFLECTO.
INSTALLATION DATA SHEET The following information must be recorded by the in staller for wa rranty purposes and future reference. Model: EG 40 20 Name of Dealer: _______________ ____________ _________.
デバイスEnviro EG 40 Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Enviro EG 40 Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはEnviro EG 40 Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Enviro EG 40 Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Enviro EG 40 Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Enviro EG 40 Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はEnviro EG 40 Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Enviro EG 40 Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちEnviro EG 40 Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。