Installation/Operation www .comlaundry .com Clothes Dryer Electric and Gas Models DRY684C Part No. 513220R4 August 2011 Keep These Instructions for Futur e Reference.
.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT 513220 1 IMPOR T ANT : Pur chaser must consu lt the local gas suppl ie r for su ggested instruction s to be followed if the dryer user smells gas.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT © Copyright 201 1, Alliance Laundry Systems LLC All rights reserved. No part of the cont ents of this book may be reproduced or transmitted in any form or by any means without the expressed writte n consent of the publisher .
3 513220 © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Safety Information Explanation of Safety Messages Throughout this manual and on machine decals, you will find precautionary statements (“DANGER,” “W ARNING ,” and “CAUTION”) followed by spec ific instructions.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Safety Informati on 513220 4 13. Keep area around th e exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt. 14. The interior of the dryer and the exhaust duct should be cleaned peri odically by qualified service personnel.
5 513220 © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation Dimensions NOTE: Side, re ar and bottom exhaust openings are 4 inch (10.2 cm) ducting. Gas models cannot be vented ou t left side o f cabinet because of burner housing.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 6 Additional Security T orx security screws are ava ilable (as optional equipment at extra cost) for securing lower access panel to dryer base. Order part number 62853.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 7 513220 Before Y ou St art T ools For most installations, the basic tools you will need are: Figure 1 NOTE: An 8 in. (20.32 cm) coin drawer is requir ed for coin drop operated models.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 8 Figure 3 D817I * NOTE: For new installations, locate top of w all vent 42 in ches (107 cm) above floo r to make venting easier to connect.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 9 513220 Step 2: Connect Dryer Exhaust System IMPOR T ANT : Installing in-line filters or lint collectors will cause incr eased static pr essure. Failure to maintain the secondary lint system will decrease dryer efficiency and may void machine warranty .
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 10 • Stat ic pressure in exhaust duct should not be greater than .6 inches water column (1.5 cm), measured with manometer pl aced on exhaust duct two feet (61 cm) from dryer (check with dryer running and no load).
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 11 513220 Exhaust System For best drying results, reco mmended maximum length of exhaust system is shown in Ta b l e 1 .
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 12 Multi-Dryer Inst allation Exhaust Requirement s Figur e 5 shows a typical example of a multiple dryer installation. Note how each dryer has its own ex haust system vented to the central exhaust duct.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 13 513220 Figure 6 Figure 7 D686I 1 NOTE: Where the exhaust duct pierces a combustible wall or ceilin g, the opening must be sized per local codes.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 14 A Backdraft Damper , Part No. 58786 (obtain locally), should be installed in a 4 inch (10.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 15 513220 NOTE: When connecting to a gas line, an equipment shut-off valve must be installed within 6 feet (1.8 m) of the dryer . An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressur e.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 16 Grounding Information This appliance must be grounded. In the event of malfunction or breakd own, grounding will red uce the risk of electric shock by providing a path of least resistance for electric current.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 17 513220 IMPOR T ANT : Use only a new U.L. listed No. 10 (copper wire only) three or four conductor power supply cord kit rated 240 V olts (minimum) 30 Amperes and labeled as suitable for use in a clothes dryer .
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 18 Connecting Power Cord with Three-Wire Plug NOTE: Four -wire cord is re quir ed for new branch- circuit in stallations, mobi le homes or where codes do not permit groundin g th rough neutral.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 19 513220 4. Use the three screws from the accessories bag to attach the power cord wir es to the terminal block. Refer to Figur e 14 . Figure 14 5. T ighten all screws firmly .
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 20 3. Remove ground screw and save for use in Step 5. Remove wire and use in Step 6. Figure 17 4. Use a strain relief and insert end of power cord through power suppl y hole.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 21 513220 Step 5: Reverse Door , if Desired NOTE: Doors with windows cannot be reversed. The door on this dry er is completely reversible. T o reverse door proceed as follows: 1.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 22 8. Using screwdriver , remove two door plugs, and reinstall on opposite side of door opening. 9. Reinstall four hinge atta ching screws, removed in Ste p 1 .
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 23 513220 The dryer is design ed to be operated on a separate branch, polarized, three-wire, ef fectively grounded, 120 V olt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse , equivalent fusetron or circuit breaker .
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Inst allation 513220 24 Gas Dryers IMPOR T ANT : This operation is to be conducted by qualified personnel only . T o view the burner flame, remove the lower front panel of the d ryer .
25 513220 © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Operation Operation Instructions IMPOR T ANT : Before using dryer for the first time, use an all-purpose cleaner , or a detergent and water solution, and a damp cloth to remove shipping dust fr om inside of dryer drum.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Operation 513220 26 Step 4: Set Fabric Selector Select HIGH TEMP , MED TEMP , LOW TEMP , DELICA TES, or NO HEA T by pu shing touchp ad . Figure 36 NOTE: Always follow manufactur er ’ s care lab el instructions.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Operation 27 513220 Indicator Light s INSER T COINS/CARD INSERT COINS/CARD is lit to prompt the user to insert coins or a card to sa tisfy the vend price. When INSERT COINS/CARD is lit, the three digits will display the vend price remaining to be satisfied.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT 28 513220 Maintenance Lubrication All moving parts are sealed in a permanent supply of lubricant or are equipped with oilless bearings. Additional lubrication will not be necessary .
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Maintenance 29 513220 Motor Overload Protector The dryer ’ s motor overload protector stops the motor automatically in the event of an overload. After cooling, the overload protector will reset itself.
© Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT 30 513220 T roubleshooting T ry th es e troubleshooting tips befo re making a service call. They may save you time and mone y . Dryer Symptom Possible Cause/Solution Dryer won’t start • Insert coin(s ) or card.
31 513220 © Copyright, Alliance Laundry System s LLC – D O NOT COPY or TRANSMIT Cont act Information If service is required, contact the nearest Factory Authorized Ser vic e Cen t er .
.
.
Inst aller Checklist Fast T rack for Inst alling the Dryer (Refer to the ma nual for more det ailed information) LEVEL D255I • Position and Level the Dryer. 1 D256I CHECK D259I D255I 2 CHECK • Connect Dryer Exhaust System. D740I D740I 3 GAS ONL Y D258I CHECK • Connect Gas Supply Pipe.
デバイスAlliance Laundry Systems DRY684Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Alliance Laundry Systems DRY684Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAlliance Laundry Systems DRY684Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Alliance Laundry Systems DRY684Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Alliance Laundry Systems DRY684Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Alliance Laundry Systems DRY684Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAlliance Laundry Systems DRY684Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Alliance Laundry Systems DRY684Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAlliance Laundry Systems DRY684Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。