Allied TelesisメーカーAT-8100S/16F8-SCの使用説明書/サービス説明書
ページ先へ移動 of 138
613-001478 Rev. D 8100S Series Fast Ethernet Switches A T -8100S/24C A T -8100S/24 A T -8100S/24POE A T -8100S/16F8-SC A T -8100S/16F8-LC A T -8100S/24F-LC Stack Installation G.
Copyright 2012 Allied Telesis, Inc. All rights reserved. No part of this pub lication may be reproduced without prior wr itten permission from Al lied Telesis, Inc. Allied Telesis and th e Allied Telesis logo are trademarks of Allied Telesis, Incor porated .
3 Electrical Safety and Emissions S tandards This product meets the following standards. RFI Emissions FCC Class A, EN55022 Cl ass A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK, CE EMC (Immunity) EN55024 Electrical Safety EN60950-1 (TUV), UL 60950-1 ( C UL US ) U.
4 T ranslated Safety S tatements Important: The indicates that translations of t he safety statement are available in the PDF document “Translated Safety Statements” posted on the Allied Telesis website at www.
5 Preface ....................... ........... ........... .............. ........... ............ ........... ........... ........... ........... . ........ ........... ........... .............. ... 13 Document Conventions ............. .............
Contents 6 Power Budget ................... .............. .............. .............. ............ .............. .............. .............. ........ ........... ............ ........... . 36 Port Prioritization ... .............. ........... ..
Stack Installation Guide for 8100S Series Switches 7 SNMP .......... .............. ............ ........... ........... ........... ........... ............ .............. ........... ...... ...................... ........... ........... .. 112 Specifying Ports in the Command Line Interface for Switc hes in a Stack .
Contents 8.
9 Figure 1: 8100S Series Switches.... ........................................................ .............. ............ .......... . ........... ........... .............. ..... 22 Figure 2: Front Panel Components on th e 8100S Twisted Pair Switches .
Figures 10 Figure 50: PORT Parameter in the Command Li ne Interface . ............ ......................... ............ ........... ........... ......... ............112 Figure 51: SHOW BOOT Command ............... ........... .............. .......
11 Ta b l e s Table 1: Hardware Features of the 810 0S Twisted Pair Series ........... ........... ........... ........... ........... ............ .............. .......... 21 Table 2: Hardware Features of the 810 0S Fiber Optic Se ries .............
Tables 12.
13 Pr eface This guide contains instructions on how to install the 8100S Series of Fast Ethernet switches in a stack con figuration. For instructions on how to install the switches as stand-alon e units, refer to the S tand-alone Switch Installation Guide for 8 100L and 8100S Series Switches .
Preface 14 Document Conventions This document uses the following conventions: Note Notes provide additional informatio n. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a sp ecific action may result in bodily injury.
Stack Installation Guide for 8100S Series Switches 15 Contacting Allied Telesis If you need assistance with this prod uct, you may contact Allied Telesis technical support by going to the Suppo rt & Services section of the Allied Telesis web site at www.
Preface 16.
17 Chapter 1 Overview This chapter contains the following sections: “Features” on page 18 “8100S T wisted Pair Series Switches” on p age 21 “8100S Fiber Optic Series Switches” .
Chapter 1: Ove rview 18 Features Here is a list of the switches and the ir features: 8100S Models Here are the 8100S Series switches: AT-8100S/24C AT-8100S/24 AT-8100S/24POE AT-8100S/1.
Stack Installation Guide for 8100S Series Switches 19 Port prioritization 10/100/1000 Mbps Twisted Pair Ports Here are the basic features of the 10/100 /1000 Mbps twisted pair ports: Two ports per switch 10Base-T, 100Base-TX, and 1000Base-T complian t IEEE 802.
Chapter 1: Ove rview 20 LEDs Here are the port LEDs: Duplex mode and lin k/activity LE Ds for the twisted pair ports Link/activity LEDs for the 100Base-FX fiber optic ports Link/activity L.
Stack Installation Guide for 8100S Series Switches 21 8100S Twisted Pair Series Switches The three twisted pair mode ls in the 8100S Series are listed here: AT-8100S/24C AT-8100S/24 AT-8100S/24POE For information on the fiber optic models, re fer to “8100S Fiber Optic Series Switches” on page 23.
Chapter 1: Ove rview 22 Front Panels The front panels of the 8100S Series switches with twisted pair port s are shown in Figure 1. Figure 1. 8100S Series Switches Front Panel Components Figure 2 identifies the front pane l components on the models with twisted pair ports.
Stack Installation Guide for 8100S Series Switches 23 8100S Fiber Optic Series Switches The three fiber optic models in th e 8100S Series are listed here: AT-8100S/16F8-SC AT-8100S/16F8-LC AT-8100S/24F-LC Hardware Features Table 2 lists the hardware featu res of the fiber optic 8100S Series switches.
Chapter 1: Ove rview 24 Front Panels The front panels of the fiber optic switches are shown in Figure 3 here and Figure 4 on page 25. Figure 3. Front Panels of the 8100 S Fiber Optic Series AT-8100S /.
Stack Installation Guide for 8100S Series Switches 25 Figure 4. Front Panels of the 8100 S Fiber Optic Series (Continued) Fiber Optic Ports Table 3 lists the general specifications of the fiber optic ports on the fiber optic switches.
Chapter 1: Ove rview 26 Back Panel Components Figure 5 shows the back panel of the AT-81 00S/24C Switch, which has a single powe r supply. Figure 5. Back Panels of the Single Power Supply Switches Figure 6 shows the back panels of the dual power supply models.
Stack Installation Guide for 8100S Series Switches 27 Management Panel Figure 7 identifies the compone nts of the management panel. Figure 7. Management Pa nel Console eco-friendly Button Stack ID Por.
Chapter 1: Ove rview 28 Model Naming Conventions The letters and numbers in the model names identify the hard ware features of the switches. The naming conventions for the t wisted pair 8100S Series switches are identified in Figure 8.
Stack Installation Guide for 8100S Series Switches 29 The conventions are defined in Ta ble 5. T able 5. Model Naming Conventions of the Fiber Optic 8100S Series Switches Convention Definition 1 This is the product name. 2 The letter “S” indicates that the model is st ackable.
Chapter 1: Ove rview 30 10/100Base-TX Twisted Pair Ports The switches have 8 or 24 10/100Ba se-TX ports. Speed The ports can operate at either 10 or 100 Mbps. The speeds may be set manually using the management softw are or automatically with Auto- Negotiation (IEEE 8 02.
Stack Installation Guide for 8100S Series Switches 31 Maximum Distance The ports have a maximum operating distance of 100 meters (328 feet). Power Over Ethernet The 10/100Base-TX ports on the AT-8100S.
Chapter 1: Ove rview 32 10/100/1000Base-T Twisted Pair Ports The switches have two 10/100/1000Base-T p orts. These ports are paired with SFP slots to form combo ports. Speed The ports can operate at 10, 100, or 1 000 Mbps. The speeds may be set manually using the management softw are or automatically with Auto- Negotiation (IEEE 8 02.
Stack Installation Guide for 8100S Series Switches 33 Maximum Distance The ports have a maximum operating distance of 100 meters (328 feet). Power Over Ethernet The 10/100/1000Base-T ports on the A T -8100S/24POE Switch does not support PoE. Cable Requirements The cable requirements of the ports are given in Table 7.
Chapter 1: Ove rview 34 SFP Slots The switches have two slo ts for 100Mbp s 100Base-FX or 1000Mbp s 1000Base-SX/LX fiber optic transceivers. Y ou may add transceivers to connect the switches to o ther.
Stack Installation Guide for 8100S Series Switches 35 Power Over Ethernet The AT-8100S/24POE Switch features Power over Et hernet (PoE) on the 10/100Base-TX ports. PoE is used to supply power to netwo rk devices over the same twisted pair cables that carry the n etwork traffic.
Chapter 1: Ove rview 36 Power Budget The AT-8100S/24POE Switch has a power bu dget of 370 watts. This is the maximum amount of power the switches can provide at one time to the powered devices. The PoE switch has two power supplies. Each power su pply is responsible for providing 185 watts, or half, of th e power budget.
Stack Installation Guide for 8100S Series Switches 37 Port Prioritization If the power requirements of t he powered devices exceed the switch’s power budget, the switch will deny power to some ports based o n a system called port prioritization.
Chapter 1: Ove rview 38 Wiring Implementation The IEEE 802.3af standard defines two me thods by which a PSE, such as the switch, can transmit DC power over t wisted pair cables to PDs. These methods, known as modes A and B, identify the wire strand s the switch should use when sending DC powe r to a PD.
Stack Installation Guide for 8100S Series Switches 39 S1 and S2 Stacking Ports The switch may be used as a stand-alone un it or as part of a stack in which multiple units are interconnected via the S1 and S2 stacking ports on the front panels.
Chapter 1: Ove rview 40 eco-friendly Button You may turn off the port L EDs to conserve electricity when you are not monitoring the switch. The LEDs ma y be toggled with the eco-friendly button on the front panel of the switch or the ECOFRIENDLY LED and NO ECOFRIENDLY LED commands in the Gl obal Configuration mode of the command line interface.
Stack Installation Guide for 8100S Series Switches 41 LEDs Here are the descriptions of the switch’s LEDs. 10/100Base-TX Twisted Pair Port LEDs The 10/100Base-TX twisted pair ports have link/activity and duplex mode LEDs. Figure 10. 10/100Base-TX Port LEDs The LEDs are described in this table.
Chapter 1: Ove rview 42 Here are the LED guidelines: The LEDs do not display port speed. That information may be viewed using the management software. The LEDs on the AT-8100S/24POE Switch do n ot display PoE information. That informati on may be viewed using the management software.
Stack Installation Guide for 8100S Series Switches 43 100Base-FX Port LEDs Each of the 100Base-FX ports on the AT-8100S/16F8 -SC, AT-8100S/ 16F8-LC, and AT-8100S/24F-LC Switches has a single LED, labeled L/A for Link/Activity. Figure 12. 100Base-FX Po rt LED The 100Base-FX port LED is described in Table 12.
Chapter 1: Ove rview 44 SFP Slot LED Each SFP slot has one LED. Figure 13. SFP Slot LEDs The SFP slot LED is described in Table 13. T able 13. SFP Slot LED LED St ate Description Link/Activity Of f The SFP slot is empty or the SFP module has not established a link to a network device.
Stack Installation Guide for 8100S Series Switches 45 S1 and S2 Stack Ports LEDs Each stacking port has one link/activity LED labelled LINK/ACT. Figure 14. Stacking Port S1 and S2 LEDs The stacking port LED is described in T able 14. Note The stacking port LEDs do not indicate pa cket activity.
Chapter 1: Ove rview 46 Stack ID LED The Stack ID LED displays the ID number of the switch. A stand-a lone switch should have the ID number 0. Switches connected with the stacking ports to form a virtual stack must h ave unique numbers.
Stack Installation Guide for 8100S Series Switches 47 Console Port The Console port is used t o configure the features and paramet er settings of the switch. This type of management uses serial RS-232 and is commonly referred to as local or out-of-band management because it is not conducted over your network.
Chapter 1: Ove rview 48 Power Supplies The switches are powered by two intern al AC power supplies, except for the AT-8100S/24C Switch, which has one power supply. The supplies are not field-replaceable and each has a separate AC connector on the back panels.
Stack Installation Guide for 8100S Series Switches 49 Power Connectors The 8100S Series switches have two AC or DC power supply sockets o n the back panels, except for the AT-8100S/24C Switch, which has just one AC power supply socket. AC switches are powered on or o ff by connectin g or disconnecting the power cords.
Chapter 1: Ove rview 50.
51 Chapter 2 S tacking Overview This chapter contains the following sections: “S tacking Guidelines” on p age 52 “Master Switch” on page 54 “S tacking Port T opologies” on page.
Chapter 2: St acking Overview 52 Stacking Guidelines A stack is a group 8100S Series switch es linked together with the S1 and S2 stacking ports to function a s a unified Fast Ethernet switch.
Stack Installation Guide for 8100S Series Switches 53 The other units are referred to as member switche s. The stacking feature described in this guide is u nrelated to the enhanced stacking feature d escribed in the A T -8100 Series AlliedWare Plus Comman d Line Interface User ’s Guid e .
Chapter 2: St acking Overview 54 Master Switch A stack must have a master switch to coordinate and monitor stack operations. It verifies that the switc hes are using the same version of management software, that no two switches have the same ID number, and that the stacking ports are cabled correctly.
Stack Installation Guide for 8100S Series Switches 55 Stacking Port Topologies The switches are connected together wi th the S1 and S2 ports in the management panels, and the stackin g cables that come with the units. There are two wiring configurations.
Chapter 2: St acking Overview 56 Figure 16 Duplex-chain and Duplex-ring Configurations Duplex-chain Configurati on Duplex-ring Configurat ion.
Stack Installation Guide for 8100S Series Switches 57 Active Boot Configuration File The master switch stores the settings of the entire stack in a file in its file system.
Chapter 2: St acking Overview 58 instructs the other switches to designate that filename as the active boot configuration file so that they use that file if they become the master switch. Here is an example of how the process wo rks. Let’s assume your stack has three switches, assigned the ID numbers 1 to 3.
Stack Installation Guide for 8100S Series Switches 59 Initialization Process The switches of the stack synchron ize their operations in a five phase process when they are powered on or rese t, and prior to forwarding network traffic from their ports. In the first three phases the switches initialize th eir management software and features.
Chapter 2: St acking Overview 60.
61 Chapter 3 Beginning the Installation The chapter contains the following sections: “Installation Overview” on p age 62 “Reviewing Safety Precautions” on p age 63 “Planning the .
Chapter 3: Be ginning the Install ation 62 Installation Overview Table 15 lists the installation procedures for a stack of 8100S Series switches. The procedures should be performed in the order presented in the table.
Stack Installation Guide for 8100S Series Switches 63 Reviewing Safety Precautions Please review the followin g safety precautions before yo u begin to install the switch.
Chapter 3: Be ginning the Install ation 64 Warning Class I Equipment. This equipment must be earthed. Th e power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket out let could place hazardous voltages on accessib le metal p arts.
Stack Installation Guide for 8100S Series Switches 65 Caution Risk of explosion if battery is re placed by an incorrect type. Replace only with the same or equivalent type recommended b y the manufacturer. Dispose of used batter ies according to the manufacturer’s instructions.
Chapter 3: Be ginning the Install ation 66 Warning Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be give n to supply connections other than direct connections to the branch circuit s (e.g., use of power strip s).
Stack Installation Guide for 8100S Series Switches 67 Planning the Installation Observe these requirements when planning the installation of t he stack.
Chapter 3: Be ginning the Install ation 68 To count the ports on the twisted pair models, in clude the two 10/100/ 1000Base-T ports along with the 10/100 Base-TX ports, but not the SFP slots.
Stack Installation Guide for 8100S Series Switches 69 Unpacking the Switch Refer to the figures in this section to verify the conte nts of the shipping container of the switch. If any items are missing or damaged, contact yo ur Allied Telesis sales representative for assistance .
Chapter 3: Be ginning the Install ation 70 AT-8100S/24C Switch The AT-8100S/24C Switch comes with the items listed in Figure 20. Figure 20. Components of the AT-8100S/2 4C Switch Note You should retain the original packaging material in the event yo u need to return the unit to Allie d Telesis.
71 Chapter 4 Installing and Labeling the Switches in an Equipment Rack Here are the procedures in this chapter: “Installing the Switches in an Equipment Rack” on p age 72 “Labeling the S.
Chapter 4: Inst alling and Labeling the Switches in an Equipme nt Rack 72 Installing the Switches in an Equipment Rack This procedure requires the following items: Eight bracket screws (included w.
Stack Installation Guide for 8100S Series Switches 73 4. For all switches excep t the AT-8100S/24C Switch, secu re the two rack mount brackets to the sides of t he switch using the eight bracket screws included with the unit. Figure 23 h ere and Figure 24 on page 74 illustrate the four pos sible bracket positions.
Chapter 4: Inst alling and Labeling the Switches in an Equipme nt Rack 74 Figure 24. Attaching the Brackets to Install the Switch in an Equipment Rack (Continued) The A T -8100S/24C Switch comes with two short brackets and one long bracket. T o install the device in an equipment rack, use on e of the short brackets a nd the long bracket.
Stack Installation Guide for 8100S Series Switches 75 Figure 26. Attaching the Brackets to the AT-8 100S/24C Switch to Install the Switch in an Equipment Rack (Continue d).
Chapter 4: Inst alling and Labeling the Switches in an Equipme nt Rack 76 5. Have another person hold the switch in t he equipment rack while you secure it using standard screws (not provided). Figure 27. Mounting the Switch in an Equipment Rack Repeat this procedure to install all of the switches in the equipment rack.
Stack Installation Guide for 8100S Series Switches 77 Labeling the Switches Starting with the top or bottom switch of the sta ck, assign each unit a number starting with 1 and affix labels with the numbers to their front panels or adjacent to the units on the equipment ra ck.
Chapter 4: Inst alling and Labeling the Switches in an Equipme nt Rack 78.
79 Chapter 5 Assigning the S tack ID Numbers and Cabling the S tacking Ports The procedures in this chapter expl ain how to con figure the stack ID numbers on the switches and cabl e the S1 and S2 sta.
Chapter 5: Assi gning the Stack ID Num bers and Cabling the St acking Ports 80 Powering on a Switch Power on one of the swit ches in the stack with these instructions. 1. Plug the power cord into the AC power connector on the back panel of the unit (see Figure 29).
Stack Installation Guide for 8100S Series Switches 81 2. Connect the other end of the po wer cord to an appropr iate AC power outlet. For power specifications for the switch , refer to “Power Specifications” on page 132.
Chapter 5: Assi gning the Stack ID Num bers and Cabling the St acking Ports 82 Verifying and Setting the Stack ID Numbers After the switch has initialized its management software, examine the number displayed on the Stack ID LED to see if it matches th e number you want it to have in the stack.
Stack Installation Guide for 8100S Series Switches 83 Figure 30. Connecting the Management Cable to the RJ-45 Terminal Port on the Switch 2. Connect the other end of the cable to an RS-232 port on a te rminal or a personal computer with a terminal emulation pro gram.
Chapter 5: Assi gning the Stack ID Num bers and Cabling the St acking Ports 84 Note Your computer automatically defaults to an 169.254. n . n address if it is running a DHCP client and does not receive a response from a DHCP server.
Stack Installation Guide for 8100S Series Switches 85 Changing the Stack ID Number To set the stack ID number: 1. When prompted, enter a user name and password to log on the switch. If this is the initial management session of the switch, enter “manager” as the user name “friend” as th e password.
Chapter 5: Assi gning the Stack ID Num bers and Cabling the St acking Ports 86 4. Type Y to change the switch’s ID number and reset the unit, or N to cancel the procedure.
Stack Installation Guide for 8100S Series Switches 87 Cabling the Stacking Ports Now that you’ve assigned and verified t he stack ID numbers of the switches, you may connect the stacking cables to the S1 an d S2 stacking ports on the front panels of the units.
Chapter 5: Assi gning the Stack ID Num bers and Cabling the St acking Ports 88 An example of a st ack of four switches is shown in th is figure. Figure 35.
Stack Installation Guide for 8100S Series Switches 89 4. To add a redundant path to the stack, connect a stacking cable to the empty stacking ports on the top and b ottom switches. An example of a stack wit h a redundant p ath is shown in Figure 36. Figure 36.
Chapter 5: Assi gning the Stack ID Num bers and Cabling the St acking Ports 90.
91 Chapter 6 Powering On and V erifying the S tack The procedures in this chapter are listed he re: “Powering on AC Switches” on page 92 “Powering On DC Switches” on pag e 97 “V .
Chapter 6: Powe ring On and Verifying the Stack 92 Powering on AC Switches To power on the stack for the first time, conn ect the power cords to the connectors on the back panels and to the appropriate power sources. All of the models have two power suppl ies with separate connect ors.
Stack Installation Guide for 8100S Series Switches 93 Warning Power cord is used as a disconnec tion device. T o de-energize equipment, disconnect the power cord. E3 Note Pluggable Equipment. The socket outl et shall be installed near th e equipment and shall be easily accessible.
Chapter 6: Powe ring On and Verifying the Stack 94 You may also monitor the processes by connecting a terminal or computer with has a terminal emulator prog ram to the Console port on the master switch. The messages in Figure 38 here, F igure 39 on page 95, and Figure 40 on page 96 are displayed du ring the initialization process.
Stack Installation Guide for 8100S Series Switches 95 Figure 39. Switch Initialization Messages (Continued ) Initializi ng Port Stat istics .... ........... ......... d one! Initializi ng Snmp Service .. ........... ............ .. done! Initializi ng Web Service .
Chapter 6: Powe ring On and Verifying the Stack 96 Figure 40. Switch Initia lization Messages (Continued) At this point, the stack is operational a nd ready to forward networ k traffic. Before connecting the network cables, go to “Verifying the Installation” on page 101.
Stack Installation Guide for 8100S Series Switches 97 Powering On DC Switches Perform this procedure to power on a stack of DC 8100S Series switches: Warning As a safety preca ution, install a circuit breaker with a minimum value of 15 Amps between the equipment and the DC power source.
Chapter 6: Powe ring On and Verifying the Stack 98 Figure 41. DC Terminal Block 3. With a 14-gauge wire-stripping tool, strip the three wires in the tray cable coming from the DC input power source to 8 mm 1mm (0.31 in., 0.039 in.), as shown in Figure 42 on p age 98.
Stack Installation Guide for 8100S Series Switches 99 Figure 43. Inserting Wires into the DC Terminal Block 5. Connect the positive feed wire to the te rminal block marked + (plus). 6. Connect the negative feed wire to the terminal block marked - (minus).
Chapter 6: Powe ring On and Verifying the Stack 100 11. Repeat this procedure to power on the secon d power supply. Warning This unit might have more than one power source. To reduce t he risk of electric shock, disconnect all power cords before servicing the unit.
Stack Installation Guide for 8100S Series Switches 101 Verifying the Installation To verify the installation of the stack, perform the following procedure: 1.
Chapter 6: Powe ring On and Verifying the Stack 102 Examine the stack ID LEDs to verify that each switch has be en assigned a unique ID numb er, in the range of 1 to 8.
103 Chapter 7 Cabling the Network Ports This chapter contains the following pro cedures: “Cabling the T wisted Pair and Fiber Optic Port s” on page 104 “Installing Optional SFP T ranscei.
Chapter 7: Cablin g the Network Ports 104 Cabling the Twisted Pair and Fiber Optic Ports This section contains the guidelin es to cabling the twisted pair and fib er optic ports.
Stack Installation Guide for 8100S Series Switches 105 The 10/100/1000Base-T ports mu st be set to Auto-Negotiation, the default setting, to operate at 1000Mb ps.
Chapter 7: Cablin g the Network Ports 106 Installing Optional SFP Transceivers Review the following guidelines bef ore installing optional SFP transceivers in the switch: The SFP slots are part of combo ports, with 10/100/1000Base-T ports. For operational information, refer to “SFP Slots” on p age 34.
Stack Installation Guide for 8100S Series Switches 107 Figure 45. Removing the Dust Plug from an SFP Slo t 2. Remove the transceiver from its shipping containe r and store the packaging material in a safe loca tion. 3. If you are installing the transceiver in t he top SFP slot, positio n the transceiver with the Allied Te lesis label facing up.
Chapter 7: Cablin g the Network Ports 108 Figure 47. Removing the Dust Cover from t he SFP Module 6. Verify that the handle on the SFP transceiver is in th e upright position, as shown in Figure 48.
Stack Installation Guide for 8100S Series Switches 109 7. Connect the fiber optic cable to the SFP module, as shown in Figure 49. Figure 49. Connecting the Fiber Optic Cable to the SFP Module 8. Repeat this procedure if you have other SFP tran sceivers to inst all.
Chapter 7: Cablin g the Network Ports 110 Managing the Stack You may manage an 8100S Series st ack with these methods and tools: Local management Telnet client Secure shell clie nt Web browser SNMPv1, v2C, v3 Local Management You may manage a stack throug h the Console port on the master switch.
Stack Installation Guide for 8100S Series Switches 111 address 169.254.1.1. Refer to your computer’s documentation for instructions on how to set the IP addre ss. Note Your computer automatically defaults to an 169.254. n . n address if it is running a DHCP client and does n ot receive a response from a DHCP server.
Chapter 7: Cablin g the Network Ports 112 Web Browser Management Yet another way to remotely manage a stack is with a web browser. A special web browser interface, featuring both non-se cure (HTTP) and secure (HTTPS) operation, lets you monitor and configure many of the switch’s features from a series of windows.
Stack Installation Guide for 8100S Series Switches 113 The slot ID value, which is used to spe cify slot numbers in a mu lti-module chassis, does not apply to 8100S Se ries switches and sho uld always be 0. The third value is a port number on the switch .
Chapter 7: Cablin g the Network Ports 114.
115 Chapter 8 T r oubleshooting This chapter contains suggestions on ho w to trou bleshoot the switch if a problem occurs. Note For further assistance, please contact Allied Te lesis Technical Support. Refer to “Contacting Allied Telesis” on page 15.
Chapter 8: Tro ubleshooting 116 Problem 3: The stack ID LEDs on the switche s of the stack are flashing the ID numbers and the letter “H” every few seconds. Solution: This is normal for th e LEDs when the switches are opera ting in a stack configuration.
Stack Installation Guide for 8100S Series Switches 117 Check that the SFP module is fully inserted in the slot. Verify that the operating specifications of the fiber optic p orts on the SFP transceiver and the remote network device are compatible.
Chapter 8: Tro ubleshooting 118.
119 Chapter 9 Adding or Removing Switches The procedures in this chapter expl ain how to add or remove switches from the stack. The chapter contains the followin g sections: “Removing or Replaci.
Chapter 9: Addin g or Removing Swit ches 120 Removing or Replacing the Master Switch This procedure is divided into the following phases: Phase 1: “Uploading the Active Configuration File” on .
Stack Installation Guide for 8100S Series Switches 121 Uploading the Active Configuration File The first step to replacing the ma ster switch of the stack is to upload the active boot configuration f ile, which co n tains the configuration settings of the stack, to your workstation or, alterna tively, to a TFTP server.
Chapter 9: Addin g or Removing Swit ches 122 sure to include the .CFG extension. This exa mple of the command uploads a configuration file called sta ck_eng.cfg: awplus# copy stack_eng.c fg zmodem 4. After you enter the command, begin the file transfer using your terminal emulator program.
Stack Installation Guide for 8100S Series Switches 123 Note If the switch has SFP modules, perform steps 3 t o 7. Otherwise, go to step 8. 3. Label and remove the fiber opt ic cable from the SFP module. Figure 53. Removing the Fiber Optic Cable from the SFP Module 4.
Chapter 9: Addin g or Removing Swit ches 124 5. Remove and label the modu le from the switch, as shown in Figure 55. Figure 55. Removing the SF P Module 6. Install the dust cover in the SFP slot, as shown in Figure 56. Figure 56. Installing the Du st Cover in the SFP Slot 7.
Stack Installation Guide for 8100S Series Switches 125 Figure 57. Removing the Stacking Cab les 9. Remove the switch from the equipment rack. 10. Go to the next procedure.
Chapter 9: Addin g or Removing Swit ches 126 5. Assign the switch its stack ID number. For instructions, refer to “Changing the Stack ID Nu mber” on page 85.
Stack Installation Guide for 8100S Series Switches 127 11. Use the EXIT command to return to the Privileged Exec mode and Issue the SHOW CONFIG command to verify that the downloaded configuration file is the new active configuratio n file.
Chapter 9: Addin g or Removing Swit ches 128 Adding a New Member Switch Here are the guidelines to adding a new me mber switch to a stack: You have to power off a stack to add n ew member switches. To minimize the disruption to net work use rs, you should add new switches to a stack during non-business hours.
Stack Installation Guide for 8100S Series Switches 129 c. If the “Current boot config” field is displaying the file name BOOT.CFG, perform this command to crea te an archive copy of it . Otherwise, go to step 2. awplus# copy bo ot.cfg archive _boot.
Chapter 9: Addin g or Removing Swit ches 130 Removing a Member Switch Here are the guidelines to removing a member switch from the stack: You may leave the stack powered on if it is cabled in the duplex- ring topology, or if it is cabled in the duplex-chain topology a nd the switch to be removed is located at the en d of the stack.
131 Appendix A T echnical Specifications This appendix contains the te chnical specifications for the 8100S Se ries Switches. For the technical specif ications for the non-sta cking 8100L Series switches, refer to the Stand-alone Switch Installation Guide for 8100L and 8100S Series Switches .
Appendix A: Technica l Specifications 132 Ventilation Environmental Specifications Power Specifications Maximum Power Consumptions Input Voltages Table 19.
Stack Installation Guide for 8100S Series Switches 133 Certifications Quality and Reliability A T -8100S/24 AC model: 100-240 VAC, 1.0 A maximum, 50/60 Hz per input DC model: 40-60 VDC, 1.5 A maximum per inp ut A T -8100S/24POE AC model: 100-240 VAC, 3.
Appendix A: Technica l Specifications 134 RJ-45 Twisted Pair Port Pinouts Figure 58 illustrates the pin layout of a n RJ-45 connector and port. Figure 58. RJ-45 Connector and Po rt Pin Layout Table 25 lists the pin signals for 10 and 10 0 Mbps. AT-8100S/16F8-LC 170,000 hours AT-8100S/24F-LC 140,000 hours Table 24.
Stack Installation Guide for 8100S Series Switches 135 Table 26 lists the pin signals w hen a port operating at 1000 Mbps. Fiber Optic Port Specifications Table 27 lists the specifications of the 100Base-FX fiber optic ports on the AT-8100S/16F8-SC Switch.
Appendix A: Technica l Specifications 136 Table 28 lists the specifications of the 100Base-FX fibe r optic ports on the AT-8100S/16F8-LC and AT-8100S/ 24F-LC Switches. Receiver Wavelength 1310 nm Sensitivity Maximum: -31.8 dBm Maximum Input Power Minimum: -14 dBm Table 28.
Stack Installation Guide for 8100S Series Switches 137 RJ-45 Style Serial Console Port Pinouts Table 29 lists the pin signals of the RJ-45 style serial Console port. Stacking Port Pinouts Figure 59 illustrates the pin layout of the S1 and S2 stacking ports.
Appendix A: Technica l Specifications 138 4 Transmit data1+ Receive data1+ 5 Ground Ground 6 Transmit data1- Receive data1- 7 Receive data0+ Transmit data0+ 8 Ground Ground 9 Receive data0- Transmit data0- 10 Not connected Not connected 11 Ground Ground 12 to 19 Not connected Not connected Table 30.
デバイスAllied Telesis AT-8100S/16F8-SCの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Allied Telesis AT-8100S/16F8-SCをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAllied Telesis AT-8100S/16F8-SCの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Allied Telesis AT-8100S/16F8-SCの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Allied Telesis AT-8100S/16F8-SCで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Allied Telesis AT-8100S/16F8-SCを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAllied Telesis AT-8100S/16F8-SCの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Allied Telesis AT-8100S/16F8-SCに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAllied Telesis AT-8100S/16F8-SCデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。