Extron electronicメーカーIPL T S SERIESの使用説明書/サービス説明書
ページ先へ移動 of 29
Setup Guide 68-1377-01 Rev . E 09 10 IPL T Series IP Link Ethernet Control Interfaces IP Link ® (IPL T S Series, IPL T SFI244, IPL T CR48) IMPORT ANT : Refer to www .
Safety Pr ecautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the pr esence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference.
.
IPL T Series • Contents v Contents Introduction ....................................... 1 About this Guide ................................ 1 IPL T Series Products .......................... 1 IPL T S Series ................................... 1 IPL T SFI244 .
IPL T Series • Contents vi.
IPL T Series • Introduction 1 Intr oduction This section gives an overview of the setup guide and describes the IPL T Series IP Link ® Ethernet Control Interfaces and the features of these products.
2 IPL T Series • Introduction IPL T S2 Features of the IPL T S2 include: 12 VDC, 1 A desktop power supply RJ-45 Ethernet receptacle T wo (2) 9-pin D RS-232, RS-422, or RS-485 serial ports - or - T wo (2) 3.
3 IPL T Series • Introduction COM 3 LAN UID# 093012052 POWER 12V .5A MAX COM 2 COM 1 COM 2 Lighting Control Ethernet RS-232 RS-232 D VD Laptop VCR Remote User Control & Administrator Monitoring .
4 IPL T Series • Introduction IPL T SFI244 Features of the IPL T SFI244 include: 12 VDC, 1 A desktop power supply RJ-45 Ethernet receptacle T wo (2) RS-232 serial ports .
5 IPL T Series • Introduction Blinds LAN POWER 12V 0.5A INPUT 2 1 3 4 5 6 7 8 1 2 3 4 Extron IPL T CR48 Ethernet Control Interface Projector Lighting System Screen Control Projector Lift Control TCP/IP Network GlobalView er ® A /V Resource Management and Re mote Con tro l Application Figure 3.
6 IPL T Series • Introduction Figure 4. Global Configurator Application Scr een Using GC you can configure a single room controller or create a Web-based remote monitoring system for hundreds of A/V devices in multiple locations. Y ou can configure an IPL T controller using GC without having the device physically connected to the A/V network.
7 IPL T Series • Introduction System Requirements The miminum system requirements for the PC on which you install Global Configurator include: Intel ® Pentium ® III, 1 GHz processor Microsoft ® Windows ® XP SP2, Windows Vista ® , or Windows 7 Microsoft Internet Explorer ® 6.
8 IPL T Series • Introduction T o install Global Configurator from an Extron Software Products Disk if Autorun is not enabled on your PC: 1. Insert the Extron Software Products Disk into the disk drive of your PC. 2. From the Windows desktop, open My Computer and select the appropriate disk drive.
IPL T Series • Setup 9 Setup This section describes the hardware setup and configuration of the IPL T Series controllers. T opics that are covered include: Front Panel Featur es Rea.
10 IPL T Series • Setup e LINK LED — A green LED lights to indicate that the unit is connected to an active network. f ACT LED — A yellow LED lights to indicate that data is being sent or received.
11 IPL T Series • Setup IPL T CR48 4 2 3 1 RELA Y 8 6 7 5 IPL T CR48 R 4 2 3 1 INPUT 100 LINK ACT 7 6 1 3 2 4 5 a Power LED — A green LED lights to indicate that the unit is receiving power . b Reset button — Recessed multiple function Reset button.
12 IPL T Series • Setup IPL T SFI244 COM1 COM2 LAN POWER 12V .5A MAX FLEX I/O 2 1 3 4 1 IR 2 3 4 TX RX TX RX G S G S G S G S MAC: 00-05-A6-XX-XX-XX S/N: IPL T SFI244 6 2 1 5 3 4 a Power connection — Connect the supplied 12 VDC power supply b LAN port — RJ-45 receptacle for network connection c COM ports — 3.
13 IPL T Series • Setup Resetting the Controller There are five reset modes (numbered 1, 2, 3, 4, 5 for the sake of comparison with other Extron IPL products) available by using the Reset button ( b ) on the front panel. The Reset button is recessed, so use of a pointed stylus, ballpoint pen, or Extron T weeker is suggested.
14 IPL T Series • Setup Connections and Wiring Power Connection T o connect the power supply: 1. Insert the 2-pole captive screw connector into the power supply receptacle on the rear panel of the controller . SECTION A–A Ridges Smooth Po wer Supply Output Cord A A 3/16” (5 mm) Max.
15 IPL T Series • Setup A cable that is wired as T568A at one end and T568B at the other (Tx and Rx pairs reversed) is a "crosso ver" cable. A cable wired the same at both ends is called a "straight-through" cable, because no pin/pair assignments are swapped.
16 IPL T Series • Setup Captive screw connector The IPL T S2, IPL T S6, and IPL T SFI244 have COM ports with captive screw connectors. The two COM ports with captive screw connectors on the IPL T S2 are common to the two 9-pin D connectors. Only one connector can be used for each COM port.
17 IPL T Series • Setup IR Ports The IPL T SFI244 has four IR ports for infrared device connection. Y ou can connect IR emitters or a wired IR control port of another device to send IR signals (with or without carrier frequencies) to display or source devices.
18 IPL T Series • Setup Flex I/O Ports The IPL T SFI244 has four Flex I/O ports that can be configured as digital inputs, digital outputs, or analog inputs. When configured as digital inputs, the Flex I/O ports can connect to switches and sensors.
19 IPL T Series • Setup Then, you must change the default settings of the controller (IP address, subnet mask, and [optional] administrator name and password) in order to use the controller on an intranet (LAN) or on the Internet.
20 IPL T Series • Setup 5. Execute a ping command by typing ping followed by a space and the new IP address at the command prompt. For example: ping 10.13.170.15 After issuing this command, the controller changes to the new address and starts responding to the ping requests, as described.
21 IPL T Series • Setup.
USA, Canada, South America, and Central America: Extron USA 1001 East Ball Road Anaheim, CA 92805 U.S.A. Europe, Africa, and the Middle East: Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands Asia: Extron Asia 135 Joo Seng Road #04-01 PM Industrial Bldg.
Extron USA - West Headquarters + 800.633.9876 Inside USA/Canada Only +1.714.491.1500 +1.714.491.1517 FAX Extron USA - East +800.633.9876 Inside USA/Canada Only +1.919.863.1794 +1.919.863.1797 FAX Extron Europe +800.3987.6673 Inside Europe Only +31.33.
デバイスExtron electronic IPL T S SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Extron electronic IPL T S SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはExtron electronic IPL T S SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Extron electronic IPL T S SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Extron electronic IPL T S SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Extron electronic IPL T S SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はExtron electronic IPL T S SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Extron electronic IPL T S SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちExtron electronic IPL T S SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。