UV-AIRE™ AIR PURIFYING SYSTEM Mode l: UV -E (For use with 12”, 18” and 28” Fiel d Controls Lamp s) (120/240 volt application) READ THESE INSTRUCTIONS CAREFULLY AND COMPLETE LY BEFORE PROCEEDIN.
Page 2 Figure 1 I. GENERAL INFORMATION This product is not sold as a medical device and is not for the purpose of diagnosis of any disease o r condition nor for use in the mitigation, treatment, or pr evention of any disease or condition. There are different size units avail able, depending on t he squ are footage of your home.
Page 3 WARNING : Disconnect electrical power supply b efore wirin g 9. Connect to an approp riate power source such as an AC power di sconnect box or to a circuit breaker pan el.
Page 4 15. Determine whether to use flat or angled bra cket. (Ref er to UV-Aire Configurations in Section III for aid in this decision) a. Flat Bracket Installation i. Remove the two hex nuts and flat bra cket from included bagged hardware. ii. Install the flat bracket a nd secure to the unit ba se with the hex nuts provided.
Page 5 18. Swing secu ring bracket over en d of lamp and h and-tighten the provided wi ng nut on stud. (See Figure 13) 19. Plug ballast plug into end of lamp and reconnect power supply. (See Figure 14) 20. Flip the red power switch to the on position.
Page 6 III. BULB MOUNTING BRACKET SEL ECTION AND INSTALLATION The UV-AIRE TM units come with an a ngled mounting bracket and flat mo unting bracket to position th e bulb either straight or at an angle. Cho ose one or the other br acket method be st suited for your needs.
Page 7 IV. MAINTENANCE 1. Inspect and clean lamp at least every 6 months. 2. Replace your UV-Aire™ Ai r Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously fo r maximum lamp life and light effectiveness.
Page 8 VIII. FLEX DUCT INSTALLATION For installations on duct system s with a metallic main duct an d flex duct branches , follow the instructions in figure 15 below. The health aspects associa ted with the use of these products and t heir ability to aid in disinfecting of environmen tal air have not been investiga ted by UL.
デバイスField Controls UV-Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Field Controls UV-Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはField Controls UV-Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Field Controls UV-Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Field Controls UV-Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Field Controls UV-Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はField Controls UV-Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Field Controls UV-Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちField Controls UV-Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。