www.Fisher.com D100305X012 Type 6 55 a nd 6 55R A ctuators for S elf-Operated C ontrol Contents Introduction 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scope of Manual 1 . . . . . . . . . . . . . . . . . . . . . . . . . Description 1 .
655 and 655R Actuators Instruction Manual Form 1292 July 2007 2 Table 1. Specifications Actuator Sizes and Maximum Casing Pressures ACTUATOR MAXIMUM CASING PRESSURE ACTUATOR SIZE Bar Psig 3A, 4A 17.2 250 3B, 4B 12.1 175 32, 42 6.9 100 33, 43 4.5 65 34, 44 3.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 3 CAUTION To avoid premature wear of the diaphragm due to debris in the pressure line to the diaphragm, install a strainer in the pipeline ahead of the regulator or relief valve. Before installing the actuator, inspect it for any damage.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 4 T able 2. Actuator Pressure-Setting Ranges (1) ACTUA- TOR SPRING PART PRESSURE REDUCTION PRESSURE RELIEF ACTUA- TOR SPRING PART PRESSURE.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 5 T able 3. Effective Diaphragm Area (1) ACTUA- TRAVEL DOWN FROM UPPER CASING STOP, mm (IN.) ACTUA - TOR 0 3 (0.125) 5 (0.1875) 6 (0.25) 10 (0.375) 11 (0.4375) 13 (0.5) 14 (0.5625) 19 (0.75) 22 (0.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 6 f. Stroke the actuator, and measure the stem movement to check travel. If the movement is more than full travel, turn the valve stem out of the actuator stem the amount of over-travel.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 7 4. Slowly open the upstream shutoff valve. Startup For Pressure-Relief Service 1. Open the needle valve in the control line. 2. Open the downstream shutoff valve. 3. Slowly open the upstream shutoff valve.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 8 pressurized, even when the valve has been removed from the pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when loosening the packing box pipe plug.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 9 diaphragm casing (key 5). Some Type 655R actuators will have travel stops (key 13, not shown) in place of three of these six cap screws. 9. If a top-mounted handwheel assembly is used, refer to steps 4 through 8 of the Disassembly portion of the Top-Mounted Handwheel section.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 10 16. To start up and adjust the actuator, follow the procedures outlined in the Startup section of this instruction manual.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 11 tightened to the proper load to prevent leakage, but not crush the material. Perform the following tightening sequence with a manual torque wrench. CAUTION Over-tightening the diaphragm cap screws (key 19) can damage the diaphragm.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 12 Parts Ordering When corresponding with your Emerson Process Management sales office about this equipment, refer to the serial number found on the actuator nameplate (key 17, figure 4).
655 and 655R Actuators Instruction Manual Form 1292 July 2007 13 Figure 4. Type 655 Actuator 30A8341-A/DOC 30A8342-A/DOC SIZE 3A AND 4A ACTUA TOR DIAPHRAGM CASINGS A APPL Y MOL Y-GREASE LUBRICANT TO A.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 14 Figure 6. Size 3B and 4B Top-Mounted Handwheel Assembly 38A1217-B/DOC APPL Y LUB P ARTS NOT SHOWN : 30 & 31 Key 6 Spring, steel COLOR CODE SPRING RATE SAFE LOAD COLOR CODE N/mm Lb/in.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 15.
655 and 655R Actuators Instruction Manual Form 1292 July 2007 16 Emerson Process Management Marshalltown, Iowa 50158 USA Cernay 68700 France Sao Paulo 05424 Brazil Singapore 128461 www.
デバイスFisher 655Rの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fisher 655Rをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFisher 655Rの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fisher 655Rの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fisher 655Rで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fisher 655Rを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFisher 655Rの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fisher 655Rに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFisher 655Rデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。