User's Instructions Nepicar House, London Road, Wrotham Heath, Se v enoaks , K ent TN15 7RS F or T echnical help or f or Ser vice call ... ALPHA HELPLINE T el: 0870 3001964 Alpha HE CB25/33 and HE SY25 W all Mounted, F an Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range Alpha HE CB25 G.
2 Alpha HE CB/SY The Alpha HE Range of boilers are wall mounted, fan assisted room-sealed boilers. The HE CB25 and HE CB33 are combination boilers providing both central heating and domestic hot water at mains pressure. The HE SY25 is a system boiler providing heating only for sealed central heating systems.
3 Alpha HE CB/SY 1. CENTRAL HEATING THERMOSTAT This thermostat controls the temperature of the water leaving the boiler for the heating system. For maximum output from the radiators the thermostat should be turned fully clockwise i.e. maximum output. If lower heating temperatures are required, turn the thermostat anti-clockwise.
4 Alpha HE CB/SY The operating sequence of the boiler is controlled by the selector switch on the control panel. When the HE CB25/33 selector switch is set to (hot water only) the boiler will only operate to provide domestic hot water, ideal for Summer use when central heating is not required.
5 Alpha HE CB/SY 1. BOILER LOCATION Always ensure the following clearances are available around the casing of the boiler:- Top: 220 mm, Bottom: 250 mm, Each side: 5 mm, Front: 450 mm Do not store any other articles in the cupboard containing the boiler and never place any clothing or combustible material on or near the boiler or flue pipe.
6 Alpha HE CB/SY 9 GAS SAFETY REGULA TIONS Current Gas Safety (Installation and Use) Regulations:- It is the law that all gas appliances are installed and serviced by a competent person, i.e. CORGI registered personnel. Failur e to install or service appliances correctly could lead to prosecution.
7 Alpha HE CB/SY 10 F A UL T FINDING FOR THE USER If you experience a problem of no heating or hot water, try to solve the problem by following the simple checks below before calling out a service engineer. Pull the controls panel cover forward and down to gain access to the controls.
06/05/D187 Part No. 1.022793 Manual compiled and designed by Publications 2000 - Tel: (01670) 356211 These instructions have been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement.
デバイスAlpha Tool.Com.HK Limited HE SY25の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Alpha Tool.Com.HK Limited HE SY25をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAlpha Tool.Com.HK Limited HE SY25の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Alpha Tool.Com.HK Limited HE SY25の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Alpha Tool.Com.HK Limited HE SY25で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Alpha Tool.Com.HK Limited HE SY25を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAlpha Tool.Com.HK Limited HE SY25の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Alpha Tool.Com.HK Limited HE SY25に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAlpha Tool.Com.HK Limited HE SY25デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。