FMIメーカー(V)S36の使用説明書/サービス説明書
ページ先へ移動 of 20
For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed.
www .fmiproducts.com 1 1 1026-01J 2 SAFETY W ARNING: Do not install a re pla ce in ser t in th is box unle ss the manufacturer's instructions with the insert specically state this repl ace has been tested for use with this insert.
www .fmiproducts.com 1 1 1026-01J 3 SPECIFICA TIONS 0" TO BOTTOM (LEF T SIDE ONLY) OUTSIDE AIR TOP SP ACERS BACK AND SIDES 3/4" AIR SP ACE HEARTH EXTENSION 52" X 16" TO PERPENDICUL.
www .fmiproducts.com 1 1 1026-01J 4 FIREPLACE INST ALLA TION FRAMING 1. Fr am e op en ing for fir ep la ce u sin g th e dimensions shown in Figures 1 and 2.
www .fmiproducts.com 1 1 1026-01J 5 DRAIN P AN (DP36) For outdoor installations, the replace enclo - sure must allow for adequate drainage and fresh air ventilation.
www .fmiproducts.com 1 1 1026-01J 6 Figure 6 - Lineal Gain Hemmed End 8" Stainless Inner Pipe 12 3 / 8 " Galvanized Outer Pipe A SSEMBL Y AND INST ALLA TION OF DOUBLE W ALL CHIMNEY SYSTEM Each double wall chimney section consists of a gal vaniz ed outer pipe, a stainl ess steel inne r ue pipe and a wire spacer .
www .fmiproducts.com 1 1 1026-01J 7 VENTING INST ALLA TION Continued When connecting chimney directly to the replace, the inner ue pipe section must be installed rst with the l anced side up. The outer pipe sectio n can then be installed over the ue pipe section with the hemmed end up.
www .fmiproducts.com 1 1 1026-01J 8 VENTING INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (3600FS-8DM-1) Fire stop spacers are requi red at each poin t wh er e th e chi mne y pe net rat es a oo r spa ce.
www .fmiproducts.com 1 1 1026-01J 9 VENTING INST ALLA TION Continued 14 3 / 8 " (36.5 cm) 30" (76.2 cm) 1" (2.5 cm) 1" (2.5 cm) Minimum Measurements 1" (2.5 cm) Opening "A" Pitch Slope Opening "A" Max. Used Flashing Model No.
www .fmiproducts.com 1 1 1026-01J 10 T erminations with 16" slip pipe sections are available. The R TT -8DM and RTTL-8DM are approved for flashing installations. When nee ded, these adj ust able ter mina tio ns may be used in combinat ion with the pipe asse mbly to achieve the correct chimney height.
www .fmiproducts.com 1 1 1026-01J 11 OPTIONAL GAS LINE INST ALLA TION Figure 19 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel (see Figure 20, page 12).
www .fmiproducts.com 1 1 1026-01J 12 OPTIONAL GAS LINE INST ALLA TION Continued CAUTION: All gas piping and connections must be tested for leaks after the installation is c om pl et ed . Af te r e ns ur in g that the gas valve is on, apply soap and water solution to all conn ectio ns and joint s.
www .fmiproducts.com 1 1 1026-01J 13 The following tips should be followed to as - sure that both the replac e and the glass door retain their beauty and function properly . Both the ue damper and the glass doors must be fully opened before starting the re.
www .fmiproducts.com 1 1 1026-01J 14 P ARTS WOOD BURNING FIREPLACE MODELS S36, S36H, S36R, S36RH, S36-LS, VS36, VS36H, VS36R AND VS36RH 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 1.
www .fmiproducts.com 1 1 1026-01J 15 KEY NO. P ART NO. DESCRIPTION QTY . 1 106638-01 Insulation Pan 1 2 ** Fireplace T op 1 3 106641-01 Fireplace Surround 1 4 106642-01 Air Rod Retainer 1 5 106643-01 .
www .fmiproducts.com 1 1 1026-01J 16 Rear Left Side Front Bottom Bottom Right Side KEY NO. P ART NO. DESCRIPTION QTY . 9 106658-03 Left Refractory , T extured White Brick • 1 108164-03 Left Refracto.
www .fmiproducts.com 1 1 1026-01J 17 TECHNICAL SERVICE Y ou may have furt her qu esti ons a bout i nsta llat ion, o pera tion , or tr oubl esho oting . If s o, co ntact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready .
www .fmiproducts.com 1 1 1026-01J 18 ACCESSORIES Continued STORM COLLAR SC1-1 For RT -8DM and RTL-8DM SC2-1 For RTT -8DM and RTTL-8DM ROUND TOP TERMINA TIONS RT -8DM, RTL-8DM ROUND TOP TERMINA TIONS W.
www .fmiproducts.com 1 1 1026-01J 19 _____________________________________________________ ______________________________________________________ ______________________________________________________.
1 1 1026-01 Rev . J 02/10 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmipr oducts.com.
デバイスFMI (V)S36の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
FMI (V)S36をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFMI (V)S36の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。FMI (V)S36の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。FMI (V)S36で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
FMI (V)S36を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFMI (V)S36の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、FMI (V)S36に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFMI (V)S36デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。