FMIメーカーGL36STEの使用説明書/サービス説明書
ページ先へ移動 of 20
For more information, visit www .fmiproducts.com NA TURAL GAS MODELS (V)GL36ST AND (V)GL36STE PROP ANE/LP GAS MODELS (V)GL36STP AND (V)GL36STEP 2-SIDED (SEE-THROUGH), VENTED DECORA TIVE GAS APPLIANCE .
www .fmiproducts.com 55173H 2 W ARNING: Improper installation, adjustment, altera - tion,service ormaintenancecan causeinjury orprop - erty damage. Refer to this manual for correct installation and operational procedures.
www .fmiproducts.com 55173H 3 SAFETy INFORMA TION W ARNING: This product c o n t a i n s a n d / o r g e n e r a t e s chemicals known to the State of California to cause cancer or birth defects or other reproduc - tiveharm.
www .fmiproducts.com 55173H 4 11. Keep the area around your replace clear of combustible materials, gasoline and other ammable vapor and liquids. Do not run re- place where these are used or stored. Do not place items such as clothing or decorations on or around replace.
www .fmiproducts.com 55173H 5 Figure 2 - T ypical T wo-Sided Fireplace Installation INTRODUCTION Models (V)GL36ST/P and (V)GL36STE/EP are decorative gas appliances that use a millivolt gas control and piezo pilot or an electronic gas control valve with an electronic ignition system respectively .
www .fmiproducts.com 55173H 6 Figure 3 - Clearances from T op V iew Figure 4 - Clearances from Side V iew MANTEL CLEARANCES W oodwork, such as wood trims, mantel s and other comb ustib le materia ls, should not be placed within 7" of the opening of this appliance (see Figure 5).
www .fmiproducts.com 55173H 7 FIREPLACE INST ALLA TION Continued FRAMING Construct framing using dimensions shown if Figures 6, 7 and 8. (Use the gure applicable to your application.) Figure 6 shows the framing dimensions prior to having the appliance in place.
www .fmiproducts.com 55173H 8 FIREPLACE INST ALLA TION Continued OPTIONAL OUTSIDE AIR KIT (MODEL AK-4) The installation of an outside air kit should be completed during the rough framing of the re- place due to the nature of it's location. Outside combustion air is accessed through a vented crawl space.
www .fmiproducts.com 55173H 9 FIREPLACE INST ALLA TION Continued GAS SUPPL Y TESTING Note: This section is intended as a guide for quali - ed technicians installing gas to this appliance. CAUTION: Do not connect appliancebefore pressuretest - ing gas piping.
www .fmiproducts.com 55173H 10 T o install: 1. Remove gas line cover plate from appliance’ s outer surround at the location to be used. 2. Remove insulation from inside the gas line conduit sleeve. 3. Run gas line through sleeve. 4. Prepare incoming black iron gas line with T eon tape or pipe joint compound.
www .fmiproducts.com 55173H 11 FIREPLACE INST ALLA TION Continued MANTELS Mantels, combustible or non-combustible, may be constructed as long as proper clearances are observed (see Figure 2, page 6 and Clearances , page 6). PILOT ASSEMBL Y ADjUSTMENT The pilot assembly is factory preset for the proper ame height.
www .fmiproducts.com 55173H 12 OPTIONAL GLASS DOOR Glass doors are optional with this gas appliance (see Replacement Parts and Accessories , page 19). Installing Glass Door 1. Be sure top spring clip hole is aligned with hole in replace frame (see Figure 21).
www .fmiproducts.com 55173H 13 OPERA TING FIREPLACE MILLIV OL T MODELS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not fol- low these instructions exactly , a re or explosion may result causing property damage, per - sonalinjuryorlossoflife.
www .fmiproducts.com 55173H 14 TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be performed. 3. Remove control access panel. 4. Pus h in gas con tr ol knob and tur n clock wis e to “OFF”.
www .fmiproducts.com 55173H 15 CLEANING AND MAINTENANCE W ARNING: Installation and repair should be done by a qualied service person. The applianceshouldbeinspected before each use and at least annuallyby a qualiedservice person.
www .fmiproducts.com 55173H 16 DO NOT CONNECT N.C.SW HE A T LIMIT SWITCH TH/TP TP TH WA LL SWITCH (SUPPLIED) TO 120V THERMOPILE PILOT IGNI TO R O F F P I L O T O N PILO T SAFET Y WIRE MAIN GAS INCOMING SUPPL Y MILLIVOL T WIRING DIAGRAM STEP DOWN TRANSFORMER EV2 SUPPL Y INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC N.
www .fmiproducts.com 55173H 17 TROUBLESHOO TING MILLIVOL T SYSTEM Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1.
www .fmiproducts.com 55173H 18 TROUBLESHOO TING ELECTRONIC IGNITION SYSTEM Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2.
www .fmiproducts.com 55173H 19 REPLACEMENT P ARTS AND ACCESSORIES Purchase these replace replacement parts and accessories from your local dealer . If they can not supply these parts, call FMI PRODUCTS, LLC at 1-866-328-4537 for referral information.
55173 Rev . H 09/09 WARRANTy KEEP THIS WARRANTy FMI PRODUCTS, LL C LIMITED WARRANTIES NewProducts Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free fro.
デバイスFMI GL36STEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
FMI GL36STEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFMI GL36STEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。FMI GL36STEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。FMI GL36STEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
FMI GL36STEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFMI GL36STEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、FMI GL36STEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFMI GL36STEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。