FMIメーカーVP325E(B)の使用説明書/サービス説明書
ページ先へ移動 of 32
For more information, visit www .fmiproducts.com MODELS P324E, VP324E, P325E(B) AND VP325E(B) NA TURAL GAS B-VENT DECORA TIVE GAS FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL FOR YOUR SAF.
www .fmiproducts.com 108794-01G 2 W ARNING: Improper installation, adjustment, al - teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in - stallation and operational procedures.
www .fmiproducts.com 108794-01G 3 SAFETY W ARNING: This product con - tains and/or generates chemicals knownto theStateof California tocausecanceror birthdefects orotherreproductiveharm.
www .fmiproducts.com 108794-01G 4 1 1. K e ep th e a r e a ar o u n d yo u r f i re p l ac e clear of combustib le materials, gasoline and other ammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around replace.
www .fmiproducts.com 108794-01G 5 W ARNING: Installation of this appliance should be done by a qualied service person well trained in the installation of such appliances.
www .fmiproducts.com 108794-01G 6 PRODUCT SPECIFICA TIONS Figure 2 - Appliance Dimensions 6 7 / 8 " 2 1 / 4 " 7" 7" Alternate Gas Supply Inlet 13 1 / 4 " 32 1 / 4 " * 27 .
www .fmiproducts.com 108794-01G 7 PRE-INST ALLA TION PREP ARA TION Figure 3 - Minimum Clearances (T op V iew) 0" 0" Clearance Nailing Flange Front Face Left Side Surround Back Drywall 2 x 4 .
www .fmiproducts.com 108794-01G 8 PRE-INST ALLA TION PREP ARA TION Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line enclosure, then all measurements must be from surface of covering.
www .fmiproducts.com 108794-01G 9 This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chim - ney l iner syst em if all are listed, insp ected and approved by local codes and/or building authorities.
www .fmiproducts.com 108794-01G 10 VENTING INST ALLA TION Continued It is not recommended that this appliance be common vented with an existing gas burning appliance.
www .fmiproducts.com 108794-01G 11 FIREPLACE INST ALLA TION Figure 12 - Removing Front Refractory Access Panel (P325E/VP325E Model Shown) Figure 13 - Installing the WRC Remote Receiver Fireplace Recep.
www .fmiproducts.com 108794-01G 12 GAS LINE HOOK-UP W ARNING: Gas line hookup should be done by your gas suppli - eroraqualiedserviceperson. W ARNING: Before you pro- cee d, make sur e your gas sup ply is OFF .
www .fmiproducts.com 108794-01G 13 3" Min. (7.6 cm) Side Wall Of Appliance Incoming 1/2" Gas Line Permitted by Local Codes Sediment T rap (Not Supplied) Figure 17- Sediment Trap FIREPLACE IN.
www .fmiproducts.com 108794-01G 14 0.5" 0.5" Figure 22 - Pan and Ember Material Clearances Grate Burner Pan Pan and Ember Material EMBER AND P AN MA TERIAL PLACEMENT 1. Open bag(s) of vermiculite and ll entire burner pan until burner tube is completely covered (see Figure 20).
www .fmiproducts.com 108794-01G 15 Figure 24 - Installing Logs 3 and 4 Log 4 Log 3 FIREPLACE INST ALLA TION Continued LOGPLACEMENTFORP325E(B)/ VP325E(B)MODELS 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 25).
www .fmiproducts.com 108794-01G 16 FIREPLACE INST ALLA TION Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left sid e of repl ace onl y . The vent can be ins tall ed through any outside wall a minimum of 3 feet belo w repla ce termi nati on cap.
www .fmiproducts.com 108794-01G 17 FIREPLACE INST ALLA TION Continued Figure 31 - Installing Optional Glass Door Spring Clip Insert Pin Into Spring Clip Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into V ertical Position Pivot Plate Slide T op Pin Into Door T rack 4.
www .fmiproducts.com 108794-01G 18 OPERA TION 1. STOP! Read safety information, column 1. 2. Turn wall switch to the OFF position. 3. Turn off all electric power to appliance. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel.
www .fmiproducts.com 108794-01G 19 TO TURN OFF GAS TO APPLIANCE 1. Turn off wall switch. 2. Turn of f all electric power to appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel.
www .fmiproducts.com 108794-01G 20 CLEANING AND MAINTENANCE W ARNING: Installation and repair should be done by a quali - ed service person. The appli - ance should be insp ecte d before each use and at least annually by a qualied service person.
www .fmiproducts.com 108794-01G 21 WIRING DIAGRAM STEP DOWN TRANSFORMER VENT SAFETY SHUTOFF SWITCH EV2 SUPPL Y INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC 120V AC 120V AC INCOMING OR BREAKER) (FUSE BOX OFF ON (SUPPLIED) WALL SWITCH GREEN BLACK WHITE 120v , 60Hz, 0.
www .fmiproducts.com 108794-01G 22 TROUBLESHOO TING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1.
www .fmiproducts.com 108794-01G 23 TROUBLESHOO TING Continued W ARNING:Ifyousmellgas • Shutoffgassupply . • Donottrytolightanyappliance. • Do not touch any electrical switch; do not use any phone in your building.
www .fmiproducts.com 108794-01G 24 TROUBLESHOO TING Continued OBSERVED PROBLEM Dark residue on logs or inside of replace POSSIBLE CAUSE 1. Improper log placement 2. A ir hol es at bu rn er i nl et blocked 3 . Burner flame holes blocked 4. Impr ope r vent ing or exc es - sive blockage 5 .
www .fmiproducts.com 108794-01G 25 ACCESSORIES Purc hase thes e acc esso ries from your loca l deal er . If they can not supply thes e acc esso ries call FMI PRODUC TS, LLC at 1-866- 328- 4537 for inform ation . Y ou can also wri te to the addr ess listed on the back page of this manual.
www .fmiproducts.com 108794-01G 26 P ARTS MODELS P324E AND VP324E 33 43 41 15 19 24 14 30 26 29 3 14 12 13 23 35 16 31 32 5 5 32 38 39 40 4 34 21 20 22 44 44 37 42 1 1 36 28 25 9 2 7 17 1 1 6 27 10 1 .
www .fmiproducts.com 108794-01G 27 P ARTS MODELS P324E AND VP324E This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY NO. P ART NO. DESCRIPTION QTY .
www .fmiproducts.com 108794-01G 28 P ARTS MODELSP325E(B) ANDVP325E(B) 33 43 41 15 19 24 14 30 26 29 17 14 12 13 24-3 18 18 24-9 NG LP 24-8 24-8 24-4 24-9 24-12 24-10 24-1 1 24-6 24-2 24-5 .
www .fmiproducts.com 108794-01G 29 KEY NO. P ART NO. DESCRIPTION QTY . 1 108769-03 Extension Deector 2 2 1 1201 Nut, #8-32 Hex Zinc. 2 3 1 1 109 Screw, #8-32 x 1/2" PPH Zinc. 2 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 1 1 186 Screw, #8-32 x 1" PPH Zinc.
www .fmiproducts.com 108794-01G 30 P ARTS LOG ASSEMBL Y KEY NO. P ART NO. DESCRIPTION QTY . - 109109-01 Log Set 1 105958-05 Front Log 1 2 105960-05 Rear Log 1 3 901 100-02 T op Right Log 1 4 901 102-02 T op Left Log 1 1 2 3 4 5 P324E and VP324E Models 1 4 2 3 P325E(B) and VP325E(B) Models KEY NO.
www .fmiproducts.com 108794-01G 31 _____________________________________________________ ______________________________________________________ ______________________________________________________ _.
108794-01 Rev . G 09/09 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES NewProducts Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free.
デバイスFMI VP325E(B)の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
FMI VP325E(B)をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFMI VP325E(B)の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。FMI VP325E(B)の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。FMI VP325E(B)で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
FMI VP325E(B)を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFMI VP325E(B)の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、FMI VP325E(B)に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFMI VP325E(B)デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。