FrymasterメーカーFDP65の使用説明書/サービス説明書
ページ先へ移動 of 60
PARTS LIST INCLUDED Frymaster, a member of the Co mmercial Food Eq uipment Service Asso ciation, recomm ends using CFESA Certified Tec hnicians. 24-Hour Service Hotline 1-800-551-8633 SEPT 2008 *81960.
Please read all sections of this manual and retain for future reference. NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster/Dean Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs.
DANGER Improper installation, adjustment, maintenance or service, and unauthorized alterations or modifications can cause property damage, injury, or death. Read the installation, operating and service instructions thoroughly before installing or servicing this equipment.
FPD65 Series Gas Fryers Installation & Operation Manual TABLE OF CONTENTS Page # 1. INTRODUCTION 1-1 1.1 After Purchase 1-1 1.2 Ordering Parts 1-1 1.3 Service Information 1-1 1.4 Computer Information 1-1 1.5 Safety Information 1-2 1.6 Service Personnel 1-3 2.
FPD65 Series Gas Fryers Installation & Operation Manual TABLE OF CONTENTS (CONT.) Page # 5. FILTRATION OPERATION 5-1 5.1 General 5-1 5.2 Filtration Preparation 5-1 5.3 Daily Filtration Operation 5-4 5.4 Operating the Filter 5-6 6. PREVENTATIVE MAINTENANCE 6-1 6.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-1 1.1 After Purchase In order to improve service, have the following chart fille d in by the Frymaster/Dean Authorized Service Technician who installed this equipment. Authorized Service Technician/FASC Address Telephone/Fax Model Number Serial Number Gas Type 1.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-2 1.4 Computer Information (cont.) The user is cautioned that any changes or m odifications not expressl y approved by the party responsible for compliance coul d void the user's authority to operate the equipment.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-3 1.6 Service Personnel 1.6.1 Definitions A. Qualified and/or Authorized Operating Pers onnel 1.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-1 2.1 Receiving and Unpacking Equipment A. Check that the containers are upri ght. Use an outward prying motion - no hammering - to remove the cartons. Unpack fryers carefully and remove all accessories from the carton and/or frypots.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-2 2.2 General Qualified, licensed, and/or authorized installa tion or service personne l only (as defined in Section 1.6) should p erform the following: • Installation and service on Frymaster/Dean equipment.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-3 2.3 Principles of Operation The incoming gas flows through orifices and is mixe d with air in the burners to create the correct ratio for proper combustion. The mixture is ignite d at the f ront end of each heat tube by th e pilot light.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-4 2.5 Pre-Installation (cont.) B. Clearances : The fryer area must be kept free and clear of all combustibles. This unit is design- certified for the following insta llations: 1. Commercial installation onl y (not for household use).
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-5 2.6 Air Supply and Ventilation DANGER This appliance must be installed with su fficient ventilation to prevent the occurrence of unacceptable concentrations of substan ces harmful to the health of personnel in the room in which it is installed.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-1 3.1 Installing the Fryer Decathlon 65 Series fryer system s are shipped in s ections. The fryers are uncrated, rem oved from pallets and assembled together.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-2 3.1 Installing the Fryer (cont.) 3. Connect red/white or red/yellow wires (Figure 4, left) between fryer sections being assembled (Figure 4, right, arrow). Oil-return will not operate properly if these wires are not connected.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-3 3.1 Installing the Fryer (cont.) 9. Install the front connecting post on the connected cabinets (Figure 8; see factory -installed posts on two-battery fryer sections). 10. Complete installation of topcap battering strips after the front connecting post has been installed (Figure 9).
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-4 3.1 Installing the Fryer (cont.) DANGER Fryers must be at room temperature and empty of oil during movement to avoid damage and possible bodily injury. DANGER Hot shortening can cause severe burns.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-5 3.2 Gas Connections (cont.) DANGER If gas odors are detected, the gas supply MU ST be shut off at the main shut-off valve. The local gas company or FASC should be contacted immediately to rectify the problem.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-6 3.2 Gas Connections (cont.) C. Manual shut-off valve : This gas service supplier-installed va lve must be installed in the gas service line ahead of the fryers in the gas st ream and in a position where it can be reached quickly in the event of an emergency.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-7 3.2 Gas Connections (cont.) I. Flexible Couplings, Connectors and Casters : 1. If the fryer is to be installed with flexible couplings and.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-8 3.3.1 Specifications 3.3.1.1 Adjustments to Different Gas Types Gas Adjustments Gas Type Natural LP Manifold Pressure† 4" W.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 3: INSTALLATION 3-9 3.3.2 Gas Conversion Procedures (cont.) Contact factory with the following info rmation when performing conversions: • Fryer Serial Number • Fryer Model Number • Gas Type • Operating Altitude Conversions can only be executed by qualified, factory-authorized personnel .
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 4: FRYER OPERATIONS 4-1 4.1 Initial Start-up WARNING The on-site supervisor is responsible for ensuring that operators are made a ware of the inherent hazards of operating a hot oil fry ing system, particularly the aspects of system operation, oil filtration, draining and cleaning procedures.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 4: FRYER OPERATIONS 4-2 4.1.1 Pilot Lighting Procedur es, Electronic Ignition Systems Initial Pilot Lighting : All Frymaster/Dean fryers are tes te d, adjusted and calib ra ted to sea level conditions before leaving the factory.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 4: FRYER OPERATIONS 4-3 4.2 Boil-Out Procedure DANGER Never leave the fryer unattended during the boil- out process. If the boil-out solution boils over, turn the fryer off immediately and let the solution cool for a fe w minutes before resuming the process.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 4: FRYER OPERATIONS 4-4 4.2 Boil-Out Procedure (cont.) G. The burners will heat the boil-o ut solution to a simm er.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 4: FRYER OPERATIONS 4-5 4.3 Final Preparation WARNING NEVER set a complete block of solid shorteni ng on top of heating tubes. To do s o will damage the heating tubes and frypot, and void the warranty. 4.3.1 Filling Fryer wi th Cooking Oil/Shortening A.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-1 WARNING Drawings and photos used in this manual are intended to illu strate operational, cleaning and technical procedures and ma y not conform to on-site management operational procedures.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-2 5.2.1 Assembling the Filter (cont.) Assemble the filter as follows: 1. Remove the filter pan co vers. 2. Place the filter leaf assembly in the bottom of the filter pan, ensuring th e filter disconnect is properly placed in the f ilter pan slot.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-3 5.2.1 Assembling the Filter (cont.) 4. Place the crumb tray in filter p an. 5. Replace the pan covers a nd install the filter pan into the cabinet. Ensure the con nections are fully engaged.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-4 5.2.2 Disassembling/Assembling and Cleaning an Optional Filter Leaf Follow these steps to clean a leaf-style filter: 1 1 2 3 4 Fil.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-5 Cleaning the Filter Leaf Assembly Clean the two seal frame pieces, screens and grid using a good quality degr easer and hot water from a spray nozzle. The groove in the seal frame pieces can be cleaned with th e edge of a Scotch-Brite or similar cleaning pad.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-6 5.3.2 Filtering Tools Assemble tools to be used for filtering. These ar e supplied with the filter starter kit included with the f.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-7 5.4 Operating the Filter 5.4.1 Filter Operation CAUTION NEVER operate the filter unit unless cooki ng oil is at operating temperature [~350°F (~177°C)]. 1. Remove fry baskets from frypot.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-8 5.4.1 Filter Operation (cont.) 4. When all the oil has drained from the frypot, connect the hose-wand assembly to the disconnect valve in th e fryer cabinet. DO NOT ACTIVATE FILTER PUMP UNTIL THE HOSE HAS BEEN PROPERLY CONNECTED.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-9 5.4.1 Filter Operation (cont.) 8. Begin the filtering process by pulling the yellow handle to open the oil- return valve (this activates the filter pump automatically ). 9. Oil will begin to pump from the f ilter pan into the frypot.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-10 5.4.1 Filter Operation (cont.) 11. After all shorten ing is pumped back into the frypot, bubbles will form, indicating air in the oil return lines. Allow the shortening to bubble for 15-30 seconds to ensure all shortening is cleared from the return lines.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 5: FILTRATION OPERATION 5-11 5.4.1 Filter Operation (cont.) 14. OPTIONAL EQUIPMENT: Drain-flushes are included on 5-ba ttery and larger Frymaster FPD65 Series fryers. After filtering frypot farthest from the filter system for 10 minutes, close th e oil return valve to stop the filtering process.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE 6-1 6.1 General DANGER Never attempt to clean the fryer during th e cooking process or when the frypot is filled with hot oil/shortening.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE 6-2 6.1.3 Periodic/ Annual The fryer should be inspected and adjusted peri odically by qualified service personnel as par t of a regular kitchen maintenance program.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE 6-3 6.1.3 Periodic/ Annual (cont.) • Check filtration system integrity as follows: − With the filter pan empty, place each oil retu rn handle, one at a time, in the "O N" position.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-1 7.1 General DANGER Hot cooking oil/shortening will cause sever e burns. Never attempt to move this appliance when filled with hot cooking oil/shortening or to transfer hot c ooking oil/shortening from one container to another.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-2 7.2 Pilot Burner Malfunction (cont.) 3. Check all connections for cleanliness and security. C. Pilot flame of proper size, but is unstable. Flame wavers and does not envelop the thermopile comp letely a t all times.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-3 7.3 Main Burner Malfunctions (cont.) D. Fryer will not reach the temperatur e setting and/or runs erratically. 1. Incorrect location of sensor probe or defective temperature sensor. 2. Loose wiring/wire connection E.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-4 7.4 Wiring Diagram, Main HI L IM IT TO J2 COMPUTER INTERFACE BOARD SPEAKER SOUND GRD 1 COM PUTER INT ERFACE BLK WHT A 2 1 BLK WHT 2 1 1.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-5 7.5 Wiring Diagram, Filter 31C 82C 35C 35C 86C 33C 33C 82C P2 T5 T4 T2 30C 27C 8C 9C 120V 12C CIRCUIT 115V INPUT 8051428A TRANSFO RMER .
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-1 8.1 Cabinetry and Related Components 2 1 3 4 7 6 5 8 9 10 12 13 14 15 16 17 18 19 20 21 11 22 23 24 25 Typical Cabinetr y C omponents (FPD66.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-2 8.1 Cabinetry and Related Components (cont.) ITEM PART # COMPONENT 1 810-0357 Caster, 5" Swivel – With Brake 2 810-0356 Caster, 5&quo.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-3 8.2 Doors, Topcaps and Related Components 2 1 3 4 5 6 7 8 9 10 11 12 13 FPD665 Show n ITEM PART # COMPONENT 1 824-1183 Topcap, 4-Battery * 824-1184 Topcap, 3-Battery 2 824-1185 Topcap, 2-Battery 3 824-0951 Wireway, Control Panel (C omponent Box: See Section 8.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-4 8.3 Frypots, Burners and Related Components 16 20 1 2 3 5 4 18 6 7 8 15 9 10 11 12 13 14 21 28 17 19 22 23 25 24 26 27 29 30.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-5 8.3 Frypots, Burners and Related Components (cont.) ITEM PART # COMPONENT 1 823-3948 Frypot- S/S- 65 Series 2 210-5170 Diffuser, Burner Tube.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-6 8.4 Component Box Components 1 CM4-S 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 17 ITEM PART # COMPONENT 1 823-3242 Control Box (Inside Non-Fil.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-7 8.5 Filter Pan and Related Components 1 2 3 4 7 8 10 11 9 5 6 12 13 14 ITEM PART # COMPONENT 1 823-4109 Pan, Filter 2 810-2141 Caster, Filte.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-8 8.6 Oil-Drain Components 6 5 7 3 1 2 15 17 18 19 20 21 22 23 16 9 Ty pical Drain Com ponents (FPD665 Sh own) 10 11 12 13 4 8 14.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-9 8.6 Oil-Drain Components (cont.) ITEM PART # COMPONENT 1 823-4189 Pipe, Drain- Right- D665 (With Oil Di sposal System) * 823-3441 Pipe, Drai.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-10 8.7 Oil-Return Components Oil Dispo sal Plumbi ng (Optional) 1 4 5 6 8 9 10 11 12 13 14 15 7 2 3 2 2 2 10 2 10 16 17 Typical Oil-Return Com.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-11 8.7 Oil-Return Components (cont.) ITEM PART # COMPONENT 3 813-0173 Union, ½" NPT BM 4 813-0003 Tee, ½" NPT BM 5 813-0165 Elbow,.
FRYMASTER FPD65 SERIES GAS FRYERS CHAPTER 8: PARTS LIST 8-12 8.8 Suction Tube, Oil-Return Components (cont.) ITEM PART # COMPONENT 1 810-0697 Disconnect, Male- Suction Tube * 826-1392 O-ring, Suction .
THIS PAGE INTENTIONALLY LEFT BLANK.
Frymaster, 8700 Line Avenue, Shrev eport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-31 8-688 -2200 FAX (Tech Support) 1-318-219-7135 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-551-8633 .
デバイスFrymaster FDP65の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Frymaster FDP65をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFrymaster FDP65の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Frymaster FDP65の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Frymaster FDP65で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Frymaster FDP65を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFrymaster FDP65の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Frymaster FDP65に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFrymaster FDP65デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。