FrymasterメーカーSuper Runner 38 Seriesの使用説明書/サービス説明書
ページ先へ移動 of 16
Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. Price: $6.00 24-Hour Service Hotline 1-800-551-8633 819-5646 09-98 Super Runner 38 Se.
This product has been certified as commercial cooking equipment and must be Installed by professional personnel as specified. We suggest installation, maintenance and repairs should be performed by your Local Dean Factory Authorized Service Agency.
2 DEAN SUPER RUNNER 38 ELECTRIC FRYER INSTALLATION & OPERATION TABLE OF CONTENTS PAGE 1 PARTS ORDERING/SERVICE INFORMATION 2 2 IMPORTANT INFORMATION 3 3 INSTALLATION 5 4 DAILY OPERATION 9 5 CLEANING AND MAINTENANCE 10 6 TROUBLESHOOTING 12 7 COMPONENT LISTING & INSTALLATION STANDARDS 13 8 WIRING DIAGRAM 14 1.
3 2. IMPORTANT INFORMATION 2.1 DESCRIPTION: The Dean Super Runner Series 38 electric fryers are energy-efficient, electrically heated units, listed by the Underwriter ’ s Laboratory and manufactured to their basic performance and application specifications.
4 c. STANDARDS : All electrical cooking appliances must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the latest editions of: U.S. Standards: 1. National Electric Code Standards ANSI/ NFPA # 70.
5 3. INSTALLATION 3.1 POSITIONING: a. Initial Installation : If installed with legs, do not push against any unit edges to adjust its position. Use a pallet or lift jack to lift it slightly and place it where it is to be installed. b. Relocating The Fryer : If relocating a fryer installed with legs, remove all weight from each leg before moving.
6 jack to raise the unit about a foot before installing the casters. c. Position the caster assembly against the leg support assembly. Align the holes in the caster assembly plate with the corresponding holes in the leg support assembly on the fryer. Insert the threaded caster bolts through the caster assembly plate into the leg support assembly.
7 The install must be reviewed at the time of installation to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be made aware there is a restraint on t.
8 and pack into cool zone (bottom) of the frying vessel. Be careful to not leave any air spaces or disturb the sensing bulbs. Melt shortening by turning the heaters “ON” for about five or ten seconds, “OFF” for a minute, repeating cycle until shortening is melted.
9 CAUTION WHEN FILTERING, NEVER LEAVE THE FILTER UNATTENDED. ALWAYS POINT THE FLEXIBLE OIL RETURN HOSE NOZZLE DOWN INTO THE FRY VESSEL TO PREVENT THE SPRAYING OF HOT OIL WHICH MAY CAUSE SEVERE BURNS. 4. DAILY OPERATION 4.1 OPENING: At opening time, always visually check that the power switch and the thermostat are “OFF”.
10 5. CLEANING & MAINTENANCE 5.1 GENERAL : Any piece of equipment works better and lasts longer when maintained properly and kept clean. Cooking equipment is no exception. The fryer must be kept clean during the working day and thoroughly cleaned at the end of each day.
11 5.5 PERIODIC : The fryer should be checked and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance program.
12 6. TROUBLESHOOTING GUIDE These troubleshooting procedures must be carried out only be a Factory Authorized Service Center or a local service company specializing in hotel and restaurant cooking appliances. The problems and possible solutions given below cover those most commonly encountered.
13 7. COMPONENT LISTING AND INSTALLATIONSTANDARDS The following is a selection of listing and installation standards applicable to non-cooking components often supplied as part of food service equipment. The selection is not intended to be complete and other nationally recognized standards may be appropriate.
14 8. WIRING DIAGRAM THREE GROUND TERMINAL FUSE CONTACTORS 1 3 1 3 5 4 2 6 5 AMP HIGH LIMIT THERMOSTAT BLUE FOR FIRE SAFETY SHUT OFF CONNECT TO SWITCH AT EXTINGUISHER HEAD K1 K2 BLK L1 L3 L2 N RED HEA.
Dean Industries, 14501 South Broadway, Gardenia, California 90248 TEL 1-310-323-5000 FAX (Parts) 1-310-327-3343 FAX (Tech Support) 1-318-219-7135 Price: $6.
デバイスFrymaster Super Runner 38 Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Frymaster Super Runner 38 Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFrymaster Super Runner 38 Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Frymaster Super Runner 38 Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Frymaster Super Runner 38 Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Frymaster Super Runner 38 Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFrymaster Super Runner 38 Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Frymaster Super Runner 38 Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFrymaster Super Runner 38 Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。