C120-E361-04EN SP ARC ® Enterprise M4000/M5000/M8000/M9000 Server RCI Build Procedure.
.
C120-E361-04EN ABOUT THIS PRODUCT This product is designed and manufactured for use in standard applications such as office work, personal device, househol d appliance, and general industrial applications.
.
C120-E361-04EN i Preface 1 This manual explains the RCI build procedure of the SP ARC Enterprise M 4000/M5000/M8000/M9000 server . This manual is intended for authorized service personnel who perform mainte nance work of the server or field engineers.
ii C120-E361-04EN Preface SP ARC Enterprise Mx000 Servers Documentation The manuals li sted below are provided for reference. (a) Manuals on the W eb The latest versions of all t he SP ARC Enterprise Series manua ls are available at the follo wing websites: Global Site http://www .
C120-E361-04EN iii Preface (b) Documentation CD For the Documentation CD, please contact your local sales represen tative. - SP ARC Enterprise M4000/M5000 Serv ers Documentation CD (C120-E365) - SP ARC Enterprise M8000/M9000 Serv ers Documentation CD (C120-E364) .
iv C120-E361-04EN Preface Prompt Notations The notation used for prompts in th is manual is shown below .Syntax of the Command Line Interface (CLI) Synt ax of the Command Line Interface (CLI) The command syntax is described below .
C120-E361-04EN v Reader's Comment Form Reader's Comment Form.
vi C120-E361-04EN Reader's Comment Form FOLD AND T APE FOLD AND T APE BUSINESS REPLY MAIL FIRST -CLASS MAIL PERMIT NO 74 1 SUNNYV ALE CA NO POST AGE NECESSAR Y IF MAILED IN THE UNITED ST ATES POS.
C120-E361-04EN vii Content s Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Reader's Comment Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii C120-E361-04EN Conten ts.
C120-E361-04EN ix Contents Figures Figure 1.1 Basic configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Figure 1.2 Cluster configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
x C120-E361-04EN Conten ts.
C120-E361-04EN xi Contents T ables Table 1.1 Command list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Table A.1The Error Status Code and Exp lanation . . . . . . . . . . . . . . . . . . . . . . . . .
.
C120-E361-04EN 1-1 CHAPTER 1 RCI Build Procedure This chapter explains the following items regarding the initial build procedure of the Remote Cabinet Interface (RCI) in the installation work.
1-2 C120-E361-04EN CHAPTER 1 RCI Build Procedure Figure 1.2 Cluster configuration Figure 1.3 Duplicat ed configuration Figure 1.4 Mixture of duplicated and unduplicated configurations RCI I/O unit RCI.
C120-E361-04EN 1-3 1.2 RCI command 1.2 RCI command RCI commands are used to display RCI configuration information and set node addresses. T o connect I/O units equi pped with RCI ports, a set up using RCI commands is required in addition to the connection with RCI cables.
1-4 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3 RCI Setup This section explains the RCI setup for the following cases: z New setup for a single RCI Host and two RCI I/O units z New setup of two RCI Hosts z When an RCI I/O unit is added later z When a RCI Host is added later Remarks: Please refer to Appendix A, "T roubleshooting.
C120-E361-04EN 1-5 1.3 RCI Setup 4 Connect the main unit and I/O units with RCI cables (see Figure 1.5 ). Connect an RCI branching conne ctor to each of the RCI por ts, and connect them with RCI cables by using a daisy-chain connection. Connect an RCI terminating resistor to the branching connector at either end of the RCI connection.
1-6 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3.2 New setup of two RCI Host s Figure 1.6 New set up of two RCI Hosts 1 Log in to the XSCF Shell. 2 On main unit A, exec ute the setrci -c stat comm and to display the RCI status. 3 V erify that the RCI address is 000f7fff .
C120-E361-04EN 1-7 1.3 RCI Setup 7 On main unit A, execute the setrci -c set command to make the settings of the host node. Since main unit A is the first unit, host_no is 1. 8 On main unit B, execute the setrci -c set command to make the settings of the host node.
1-8 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3.3 When an RCI I/O unit is added later Figure 1.7 When an RCI I/O unit is added later 1 Connect the I/O unit to be added with an RCI cable by using a daisy-chain connection (see Figure 1.
C120-E361-04EN 1-9 1.3 RCI Setup 1.3.4 When a RCI Host is added later Figure 1.8 When a RCI Hosts is added later 1 Log in to the XSCF Shell. 2 On main unit B, which is to be added, execute the setr ci -c stat command to display the RCI status. 3 V erify that the RCI address is 000f7fff .
1-10 C120-E361-04EN CHAPTER 1 RCI Build Procedure 7 Execute the setrci -c addconfig comm and on main unit B to expand the RCI configuration. 8 Display the RCI status by executing the setrci -c stat command on main unit A. 9 V erify that the added main unit is incorporated.
C120-E361-04EN 1-1 1 1.3 RCI Setup Remarks: Up to 32 RCIs including the RC I main unit can be connected. Use the repeater function of the external power controller to extend the cable length used and to increase the number of connected RCI device. Note that the maximum RCI cable length is 150 meters.
.
C120-E361-04EN A-1 Appendix A T roubleshooting A This appendix explains how to deal with possible prob lems during the RCI setup. z In the Case Where Setrci Command E nded Abnormally and Displayed “Operation Failed Error S tatus: XX” z In the Case Where RCI Status of RCI Host Changes From ACTIVE to INACTIVE A.
A-2 C120-E361-04EN Appendix A T roubleshooting 20 Detected the duplicate RCI address in RCI I/O unit (Expansion file unit, External power controller). Pattern C 30 Detected the duplicate RCI address in RCI I/O unit (Line selector switch). Pattern F fd RCI construction cannot be co nstructed, or it was cancelled.
C120-E361-04EN A-3 A.1 In the Case Where Setrci Command Ended Abnorm ally and Displayed “Operation Failed Error S tatus: XX” Remedy p attarn z Pattern A 1 Check the RCI setup procedure, the RCI address value and the connection. 1 Check the setting of the RCI address and the duplicate of the RCI address by setrci -c stat command.
A-4 C120-E361-04EN Appendix A T roubleshooting A.2 In the Case Where RCI S t atus of RCI Host Changes From ACTIVE to INACTIVE Remarks: When this probl em has occurred, do not replac e the XSCF unit because it is not a failure of the XSCF unit. This problem is occurred by the mistake of the RCI construction procedure and the RCI connection.
.
Back Cover.
デバイスFujitsu C120-E361-04ENの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fujitsu C120-E361-04ENをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFujitsu C120-E361-04ENの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fujitsu C120-E361-04ENの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fujitsu C120-E361-04ENで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fujitsu C120-E361-04ENを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFujitsu C120-E361-04ENの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fujitsu C120-E361-04ENに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFujitsu C120-E361-04ENデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。