FujitsuメーカーM4000の使用説明書/サービス説明書
ページ先へ移動 of 36
SP ARC ® Enter pr ise M4000/M5000 Ser v ers Product Notes F or XCP v ersion 1041 Order No . U41739-J-Z816-4-76 October 2007, Re vision A.
Please Recycle Copyright 2007 Su n Microsystems, Inc., 4150 Network Circle, Santa Cl ara, Califor nia 95054, U.S.A. a nd FUJITSU LIMITE D, 1-1, Kam ikodana ka 4-chome, Nakahara -ku, Kaw asaki-shi, Kanagawa-k en 211-8588, Japan. All rights reserved. Sun Microsystems, Inc.
Copyright 2007 S un Microsystems, Inc., 4150 Network Circle, Santa Cl ara, California 9 5054, U.S.A. et FUJIT SU LIMITED, 1-1, Kami ko danaka 4-chome, Nakahara-ku , Kawasaki-shi, Kanagawa-ken 211-8588, Japon. T ous droits réservés. Entrée et revue tecnical four nies par Fujitsu Lim ited sur des parties de ce matériel.
.
v Contents Preface vii Technical Support vii Software Resources vii Accessing Documentation viii Fujitsu Siemens Computers Welcomes Your Comments viii SP ARC Enterprise M 4000/M5000 Servers Product No.
vi SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007 DIMM Replacement 1 1 Software Iss ues 13 XCP Issues and W orkarounds 13 Solaris Issues and W orkarou nds 16 .
vii Preface These product notes contain late-breaking information about the SP ARC ® Enterprise M4000/M5000 server hardw are, software, or documentation that became known after the documentation set w as published.
viii SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1041 • October 2007 Accessing Documentation Instructions for installing, admini ster ing, and using your SP ARC Enter prise M4000/M5000 servers are provided in th e SP ARC Enterprise M4000/M5000 serv ers documentation se t.
1 SP ARC Enterprise M4000/M5000 Serv ers Product Notes These product notes contain late-breaking information about the SP ARC ® Enterprise M4000/M5000 server hardw are, software, or documentation that became known after the documentation set w as published.
2 SP ARC Enter prise M4000/M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 Caution – CR ID #6534471 : Improper handlin g of large page in kernel memory may cause random panics. Implement the w orkaround for CR ID #6534471 or check for the ava ilability of a patch and install it immediately .
SP ARC Enter prise M4000/M 5000 Ser vers Prod uct Notes 3 Known Issues This section describes known issues in thi s release. General Functionality Is sues and Limitations ■ Because the term, admin, will be reserved for the system use in next vers ion of XCP , please avoid using it to user acco unt nam e.
4 SP ARC Enter prise M4000/M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 ■ For 4447A-Z/X4447A-Z, PCIe Quad-port Gigabit Ethernet Adapter UTP cards, these maximum limits apply: .
SP ARC Ent erpr ise M4000/M500 0 Servers Product Notes 5 About the interference of nut When y ou mount the SP ARC Enterprise M4000 or M5000 server on the 19-inch rack, as y ou insert it all the way seated in the rack, the nut anchoring the bezel may interfere with the rack column and the server may fail to be seated correctly .
6 SP ARC Enter prise M4000/M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 2. In place of the removed nut and ring, attach the E-Ring , included in the rack mount kit. 3. Insert the server all the w ay seated in the rack, to lock it in place.
SP ARC Ent erpr ise M4000/M500 0 Servers Product Notes 7 Hardw are Documentation Updates T ABLE 2 lists known documentation updates. T ABLE 2 Documentation Updates Title Pa g e Number Update All SP ARC Enterprise M4000/M5000 Servers documentation All DVD references are now re ferred to as CD-RW/ DVD-RW .
8 SP ARC Enter prise M4000/M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 SP ARC Enterprise M4000/M5000 Servers Service Manual 4-11 4.
SP ARC Ent erpr ise M4000/M500 0 Servers Product Notes 9 Electrical Specifications The following changes belong in the SP ARC Enterprise M4000/M5000 Servers Service Man ual.
10 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 Cable Connections The following chang es belong in the SP ARC Enterprise M4000/M5000 Serv ers Installation Guide.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 11 Updates of the SP ARC Enterprise M4000/M5000 Serv ers Serv ice Manual The following information supersedes the i nformation in the SP ARC Enterprise M4000/M5000 Serv er s Service Manual . Installing the PCI Cassette Caution – Do not force the PCI cassette into a slot.
12 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 Here are the DIMM mount conditions: DIMM mounting rules: ■ Four(4) DIMMs per group can be mounted. ■ Capacity of the DIMMs in group A must be equal to or large r than the capacity of the DIMMs in gr oup B.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 13 Softw are Issues This section describes softw are specific issues and w orkarounds. XCP Issues and W orkarounds T ABLE 5 lists known XCP i ssues and possible workaroun d s.
14 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 RTIF1- 070418-023 Using the rebootxscf (8) command may result in a process down error , and possibly an FMA event with MSG ID SCF-8005-NE. Ignore this event.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 15 RTIF1- 070904-005 Time can't be synchronized with the NTP serve r . Check the stratum value of the NTP server . The stratum v alue of XSCF is "5." The NTP server which the XSCF refers to must be a server on which the stratum value is smaller than 5.
16 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 Solaris Issues and W orkarounds T ABLE 6 lists known iss ues and possible workarounds.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 17 6466617 P erforming a hot plug ope ration with the PCI- Express slot too quic kly interrupts a PCI lea f reset and fails, creating a cfgadm: Comp onent system is bu sy error . P ause a few seconds bet ween the issue of each cfgadm -c command.
18 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 6496337 The "cpumem-diagnosis" m odule may fail to load after un correctable error( UE) panic. Systems will function corr ectly but events normally automaticall y diagnosed by FMA using this module will require manual diagnosis.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 19 6502204 Unexpected error mes sages may be displayed on console on booting af ter CPU UE panic.
20 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 6515648 "Replumb Failed " error appear s when dr@0:SB1::memory fails. Once the DR operation is complete, it c an be plumbed up manually . Example steps to re-plumb the interface manually: # ifconfig interface plumb xxx.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 21 6527811 showhardconf (8) on X SCF can n ot display PCI card in formation t hat is insta lled in External I/O Expansion Uni t, if the External I/O Expansion Unit i s configured using PCI hotplug.
22 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 6534471 Domain may panic. Add the following line to /etc/system and reboot the domain. set heaplp_use_stlb=0 This bug has been fixed by 125100-06. 6535564 PCI hot plug to PCI slot #0, #1 or External IO Expansion Unit may fail on XSB added by DR.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 23 6542632 Memory leak in PCIe module if driver attach fails. There is no workaround. Check for the availability of a patch for this defect.
24 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 6559504 Messages of the form nxge: N OTICE: nxge_ipp_eccue_v alid_ check: rd_ptr = nnn wr_ptr = nnn wil.
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 25 6572593 fmdump(1M) may show wrong faulty component wh en IOU hardware error occurs. Check system sta tus on XSCF .
26 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 Identifying P ermanent Memory in a T arget Board 1. Log in to XSCF . 2. Execute the following command: The following examp le shows a display of the showdevices -d command where 0 is the domain_id .
SP ARC Enter pr ise M4000/ M5000 Ser vers Product Notes 27 Softw are Documentation Updates This section conta ins late-breaking softw a re information that became known after the documentation set w as published and correctio ns in the SP ARC Enterprise M4000/M5000 Servers Softw are documentation.
28 SP ARC Enter prise M4000 /M5000 Ser vers Product Notes for XCP V ersion 1041 • October 2007 SP ARC Enterprise M4000/M5000/M8000/ M9000 Servers Dynamic Reconfiguration (DR) User's Guide 2-27 2.5 "Operation Manageme nt" The following sections will be added: 2.
デバイスFujitsu M4000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Fujitsu M4000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはFujitsu M4000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Fujitsu M4000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Fujitsu M4000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Fujitsu M4000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はFujitsu M4000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Fujitsu M4000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちFujitsu M4000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。