SWITCHER MANUAL PART NUMBER: 400 - 0378 - 004 2– IN, 1 – OUT TWISTED PAIR AUTO - SWITCHER USER’S GUIDE SW1956CT.
SWITCHER 400 - 0378 - 004 1 TA BLE OF CONTENTS Page PRECAUTIONS / SAFETY WA RNINGS ................ 2 GENERAL .......................................................... 2 INSTALLATION .................................................. 2 CLEANING .....
SWITCHER 400 - 0378 - 004 2 PRECA UTIONS / SA FETY WA RNINGS 1 Please read this manual carefully before using your SW1956CT Switcher. Keep this manual handy for future reference. These safe ty instructions are to ensure the long life of your SW1956CT and to prevent fire and shock hazard s .
SWITCHER 400 - 0378 - 004 3 AB OUT YOUR SW1956CT 2 SW1956CT 2- In, 1 Out Twisted Pair Auto - Switcher The SW1956CT is a 2 - In, 1 - Out Tw isted Pair Auto - Switcher. The SW1956CT switches automatically up on signal detection, but may also be controlled manually.
SWITCHER 400 - 0378 - 004 4 MECHA NICA L SW1956CT Mate rial 0.1 00 in Al Finish Gray Height 3.00 0 in ( 76 mm) Wi dth 4.38 0 in (111 mm) Depth 1.00 0 in ( 25mm) We ight 0.4 0 lb (0.18 kg) Ship W eight 2.0 0 lb (0.91 kg) T ° Operating 10 ° C- 35 ° C T ° Maximum 50 ° C Humidity 90 % non - condensing MTBF (calculations) 40, 000 hrs (min.
SWITCHER 400 - 0378 - 004 5 PRODUCT DESCRIPTION 4.
SWITCHER 400 - 0378 - 004 6 AP PLICA TION DI AG RA MS 5 DIA GRA M 1 : TYPICA L SETUP DA1931CT SW1956CT DA1930CT DA1930CT ALTINEX includes a remote control switch with the SW1956CT. The remote switch has a 6 ft cable and may used to control the switcher manually.
SWITCHER 400 - 0378 - 004 7 DIA GRA M 2 : INTERNAL VIEW INPUT2 9 VDC, 500 mA 2.5 mm SUPPLY POWER INPUT1 CLOUSURE CONTACT DETECT SIGNAL INPUT2 INPUT1 PAIR TWISTED RJ-45 TWISTED RJ-45 PAIR OUTPUT.
SWITCHER 400 - 0378 - 004 8 INSTA LLING YOUR SW1956CT 6 Step 1. Connect t he A LTINEX power adapter that is supplied with the unit to the power port. CA UTION: The PO WE R port and the INPUT SELECT port use the same connector type. Make sure the power adapter is co nnected to the POW ER port.
SWITCHER 400 - 0378 - 004 9 TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied SW1956CT unit. H owever, we would like to offer the following suggestions: 8.1 POWER LED IS OFF Cause 1: The pow er adapter is installed wr ong.
SWITCHER 400 - 0378 - 004 10 Solution 3: Bypass the switcher and connect the output of the t ransmitter directly to the input of the receiver. If the display is good, then call ALTINEX at (714) 990 - 2300. If there is still no display, see Cause 4. Cause 4: Cable connections are incorrect.
デバイスAltinex SW1956CTの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Altinex SW1956CTをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAltinex SW1956CTの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Altinex SW1956CTの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Altinex SW1956CTで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Altinex SW1956CTを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAltinex SW1956CTの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Altinex SW1956CTに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAltinex SW1956CTデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。