W ater Heaters Electric F or Manufactured Housing (Mobile Home) Model: GE Series The purpose of this manual is twofold: on e, to provide the installer with the basic dir ections and recommendations f .
Safety Information S afety P recautions . . . . . . 3, 4 Installation Instructions Location . . . . . . . . . . . . . . . . . . 5 Wa ter Connections . . . . . . . . 6 Electrical Connections . . . . . 8 Operating Instructions S afety Controls . . . . .
Safety Instructions Installation Instructions Operating Instructions Care and Cleaning T roubleshooting Tips Customer Service Time/T emperature Relationship in Scalds W ater T emperature Time T o Prod.
4 IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! F or your safety , the inf ormation in this manual must be followed to minimize the risk of fir e or explosion, electric shock, or to pr event property damage, personal injur y , or loss of life .
Installing the water heater . The location chosen f or the water heater must take into consider ation the following: Local Installation Regulations The installation of this water hea ter must be in ac.
Installing the water heater . 6 Thermal Expansion W ater Supply Connections T ypical Side Connect Installation Anode NOTICE: Do not apply heat to the HOT or COLD wa ter connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater .
W ARNING: The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate. A new combination temper atur e and pressur e r elie f v alve, complying with the Standar d for Relief V alves and Automatic Gas Shut-Off D evices f or Hot Wa ter Supply Systems , ANSI Z21.
8 Installing the water heater . CAUTION: The presence of water in the piping and water heater does not provide sufficient conduction for a ground. Non-metallic piping, dielectric unions, flexible connectors etc. can cause the water heater to be electrically isolated.
9 Insulation Blankets Insulation blankets , available to the gener al public, for external use on electric water heaters are not necessary . The purpose of an insulation blanket is to r educe the standby heat loss encountered with stor age tank heaters.
10 Customer Service T roubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions Installing the water heater . F or increased ener gy efficiency , some water heaters hav e been supplied with a 2-3/8” section of pipe insulation.
11 Safety Instructions Installation Instructions Operating Instructions Care and Cleaning T roubleshooting Tips Customer Service Installation checklist. W ater Heater Location ■ Close to ar ea of heated water demand. ■ Indoors and protected from fr eezing temperatur es .
12 Customer Service T roubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions Safety Precautions Do turn off power to water hea ter if it has been subjected to over heating, fir e, flood, physical damage.
13 If adjustment is necessary… T urn off the power to the wa ter heater . Remove the jacket access panel(s) and insulation exposing the thermostat(s). The thermostat protectiv e cover(s) should not be r emoved. Using a small scr ewdriver , set the thermostat(s) dial pointer(s) to the desir ed temperatur e.
14 Routine Preventative Maintenance P r operly maintained, your water heater will provide years of dependable tr ouble- fr ee ser vice. It is suggested that a r outine prev entive maintenance progr am be established and follow ed b y the user .
15 Problem Possible Causes What T o Do Rumbling noise W ater conditions in your ● Remove and clean the hea ting elements. home caused a build up of scale or miner al deposits on the heating elements . Relief valve P r essur e build up caused ● This is an unacceptable condition and must be producing popping by thermal expansion corr ected.
Customer Service T roubleshooting Tips Care and Cleaning Operating Instructions Installation Instructions Safety Instructions Replacement P arts. F or 20–52 gallon models with single or double elements .
Cavity Insert Instructions The following instructions are intended for qualified service personnel ONL Y , and should only be done when necessary . In or der to r eplace the thermostat or heating element, r emove the cavity inser t crossbar by f ollowing the instructions below: T urn off the power to the wa ter heater .
18 Wiring diagrams. Wiring Diagrams for T ype–59T Therm-o-disc Thermostats 2 1 2 THERMOST A T & HIGH TEMP . LIMIT (ECO) HEA TING ELEMENT RED BLACK BLACK L1 G* BRANCH CIRCUIT TO ELECTRICAL DISTRIBUTION P ANEL 240 V . JUNCTION BOX 4 L2 RED 1 3 2 UPPER THERMOST A T & HIGH TEMP .
19 Rheem Manufacturing Company W arr anty Registra tion D epar tment P .O. Box 34070 Louisville, KY 40232-4070 Please place in envelope and mail to: ✁ Cut here ✁ Cut here.
20 ✁ Cut here Consumer Product Ownership Registration F ollow these three steps to protect your new appliance investment: If you require service, call 800-431-1549. 12 3 Model Number Serial Number Consumer Product Ownership Registration Model Number W ater Heater Serial Number Important Mail T oday! First Name Mr .
デバイスGE AP12170-4の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GE AP12170-4をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGE AP12170-4の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GE AP12170-4の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GE AP12170-4で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GE AP12170-4を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGE AP12170-4の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GE AP12170-4に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGE AP12170-4デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。