GE Security NetworX TM Series NX-7002 GSM/GPRS module Installation manual g imagination at work.
NX-7002 Inst allation ma nual Page 2 09/02/05.
C ONTENTS CONTENTS ............................................................................................................................................................................3 GENERAL INFORMATION ......................................
G ENERAL INFORMA TION The NX-7002 is the GPRS module that can be added to the NetworX range of panels ( NX-8- EUR, NX-6-EUR and NX-4-EUR). The NX -7002 GPRS module features include: • Wireless event reporting. • Six programmable report de stinations.
F E A TURE DEFINITIONS CID Contact ID reporting pr otocol. CSD Circuit Switched Data. This i s the communication used to upload/download data. It is simil ar to a modem but it is wireless and built in to the NX-7002 (see locati ons 0, 162 segment 10 and location 168).
SIM card PUK code See PUK code SMS Short Message Service. SMS is a service for sending short text messages to mobile phone s (see locations 1, 145, 163, 164, 167). Transparent mode Data is transferred directly from one modem to anot her modem (see l ocation 0 segment 1).
P ROG R AM MI N G H E NX-7002 GPRS MODULE Programming the NX-7002 via the LED keypad ENTERING THE PROGRAM MODE To enter the progra m mode, press [*]- [8]. At this ti me, the five function LED’s (Stay, Chime, Exit, Bypass and Cancel) will begi n to flash.
EXITING THE PROGRAM MODE When all the desired changes in p rogramming have be en made, it is time t o exit the program mode. Pressing the [Exit] ke y will exit this programming level and then retur n to the “Select a Module to Program” level.
Once the data is progra mmed, press the [*] key to enter the data and advance t o the next segment of that location. A fter the last seg ment of a location is pr ogrammed, pressing th e [*] key will exit that location, tur n the “Ready” LE D off and the “Armed” LED on.
S TA R T U P , ENROLLING AND TESTING THE NX-7002 Inser ting the SIM card Note: You must be free of a ll static electricity when handling electronic components. • Always power down the s ystem before inserting a SIM Card. • Locate the SIM card holder n on the bo ard.
Enrolling the SIM car d on the GSM network • Insert the SIM card. See Inserting the SIM card for more information. • Power up the NX-7002 GPRS module. • Enter programming mode. S ee Programming he NX-7002 GPRS module for more information. • Press 78# to select the module.
T esting the RSSI value During the enrolling proced ure, it is mandatory to check the RSSI v alue (signal strength) of the NX-7002 GPRS module and record it in the system documentation. The RSSI value is linked to the signal level of the GSM n etwork and ranges from 0-3 1 with 99 as unknown.
P ROGRAMMING THE LOCA TIONS LOCATION 0 MODULE MODE OF OP ERATION FEATURE SE LECTION (8 segments) This location contains t he system characteristics. Segment 1 1 = Enable site initiated downl oading (*98 from a keypad) 2 = Enable remote initiated dow nloading This setting enables the PC to dial into the NX-7002.
LOCATION 1 DESTINATION SELECTION FOR REPORT CONTROL 1 (1 s egment) The NX-7002 contains up to six report controls. Each report co ntrol can be defined for SMS reporting, TCP/IP reporti ng or email reporting (not yet av ailable). This location contains the report destination for re port control 1.
LOCATION 4 EVENT SELECTION FOR REPORT CONTROL 1 BY PARTITION (16 segments, feature selection data) All events for report control 1 are enabled by defaul t.
LOCATION 12 EVENT SELECTION FOR REP ORT CONTROL 3 BY PARTITION (16 segments, feature selection data) All events for report control 3 are disabled by defa ult. See location 4. LOCATION 13 DESTINATION SELECTION FOR REPORT CONTROL 4 (1 segment) This location contains t he report destinati on for report contr ol 4.
LOCATION 24 EVENT SELECTION FOR REPORT CONT RO L 6 BY PARTITION (16 segments, feature selection data) All events for report control 6 are disabled by defa ult. See location 4. LOCATION 25 PRIMARY REPORTING FLAG FOR REPORT CONTROLS (1 segment) The NX-7002 contains up to six re port controls.
LOCATION 62 NAME OF GPRS ACCESS POINT - APN, characters 33 - 48 (16 segments) See location 60. LOCATION 63 NAME OF GPRS ACCESS POINT - APN, characters 49 – 64 (16 segments) See location 60.
LOCATION 144 TCP/IP 2 LINE NUMBER (4 segments) See location 141. LOCATION 145 SMS 1 ACCOUNT NUMBER (8 segments) The SIA account number used for SMS reporting. S IA account numbers are 6 digi ts long. Enter the first digit of the S IM PIN code in segment 3 (segmen t 1 and 2 are not used).
LOCATION 162 TIMERS AND COUNTERS (16 segments, numerical data) Location 162 contains the duration of various system timi ng functions. Segment 1 Max Number of netw ork attempts The number of report attempts the NX-7002 GPRS module makes to send a report.
LOCATION 164 SMS 1 FORMAT (1 segment) The communicator format used to transmit to the SMS 1 report destination from the NX-7002 GPRS module. Consult the instructions for your central station receiver to de termine which format is compatible.
LOCATION 165 SMS 2 PHONE NUMBER (20 segments) See location 163. LOCATION 166 SMS 2 FORMAT (1 segment) See location 164. Note: By default, not more than 20 SMS mess ages will be trans mitted in a 24 hour time period. If needed, this number can be changed (see location 162 segment 3).
LOCATION 174 DEVICE STATUS FLAGS (2 segments) This location contains sp ecific status informati on of the GSM/GPRS module. If the opt ion is ”On”, the status condition is true.
NX-7002 FOR PRIMARY OR BACKUP REPORTING NX-7002 for primary reporting The NX-7002 can be configured to be the primary transmitter. In this case, the NX-7002 acts as the main alarm reporting device.
The NX-7002 can be configured as the backup de vice of an auxiliary dialler (NX-590 TCP/IP module or NX-570 ISDN module): • Select the desired report con trol in location 1. • Enable the Autotest report options. • Ensure that the reportin g format used with the auxiliary dialler is the same as t he reporting format used in the NX-7002.
NX-7002 PROGRAMMING WORKSHEE TS (Factory defaults are in bold italic text) LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA MODE OF OPERATION FEATURE SE LECTION Segment 1 (Circle Numbers To Pr ogram) Segme.
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 2 (BY PARTITION) Segment 1 Alarms and Restores 0- 0-0-0-0- 0-0-0 Segment 2 Open/Close 0-0-0-0-0- 0-0-0 Segment 3 Bypass 0-0-0-0-0- 0-0-0 Segment 4 Zone Trouble 0-0-0-0-0- 0-0-0 Segment 5 Power Trouble (AC Failure / Low Batt.
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 4 (BY PARTITION) Segment 1 Alarms and Restores 0- 0-0-0-0- 0-0-0 Segment 2 Open/Close 0-0-0-0-0- 0-0-0 Segment 3 Bypass 0-0-0-0-0- 0-0-0 Segment 4 Zone Trouble 0-0-0-0-0- 0-0-0 Segment 5 Power Trouble (AC Failure / Low Batt.
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA EVENT SELECTION FOR REPORT CONTROL 6 (BY PARTITION) Segment 1 Alarms and Restores 0- 0-0-0-0- 0-0-0 Segment 2 Open/Close 0-0-0-0-0- 0-0-0 Segment 3 Bypass 0-0-0-0-0- 0-0-0 Segment 4 Zone Trouble 0-0-0-0-0- 0-0-0 Segment 5 Power Trouble (AC Failure / Low Batt.
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA 154 20 Account num ber partition 1 0-0-0-0-0- 0-0-0 155 20 Account num ber partition 2 0-0-0-0-0- 0-0-0 156 20 Account num ber partition 3 0-0-0-0-0- 0-0-0 .
LOC PG DESCRIPTION DEFAULT PROGRAMMING DATA DEVICE STATUS FLAGS (read only) Segment 1 1 On = Communica tion with GSM modem OK 2 On = SIM card PIN is OK 3 On = Logg ed in to the GS M network 4 On = Sen.
I NST ALL A TION GUIDELINES • Avoid installing the module: - Where temperatures excee d 49°C or fall below 0°C. - In the immediate vicinity of electronic equipment. - In humid rooms. The module is not her metically sealed and excess moistur e on the circuit board can eventually cause an electrical fault.
NX-7002 L A YOUT AND DESCRIPTION 9 8 1 2 3 4 1 1 11 10 7 5 7 6 DESCRIPTION 1 Future use (VVMIQ) 2 SIM card holder 3 GPRS modem 4 Connect antenna t o this connector 5 Header for software upgrade 6 Conn.
T ECHNICAL SPECIFICA TIONS T e chnical specif ications NX-7002 Power supply voltage 12Vdc Current cons umption - Nominal 30mA at 13.8Vdc - Maximum up to 2 Amps peak Battery max.
A PPENDIX 1: R EP OR TING FIXED CODES IN C ONT ACT -ID AND SIA The table below lists the event codes sent for the following reports (if enabled) when using Contact ID or S IA formats.
REPORT CONTACT ID SIA FAIL TO CLOSE 454 CI ZONE ACTIVITY FAU LT 391 NA ZONE ACTIVITY RESTORE 391 NS RF JAMMING 344 XQ RF JAMMING RESTORE 344 XH SMOKE DETECTOR CLEAN ME 393 YX SMOKE DETECTOR CLEAN ME RE STORE 393 YZ THE NUMBER IN PARENTHESES FOLLOWI NG THE EVENT IS THE NUMB ER THAT WILL BE REPORTED AS THE ZONE N UMBER.
A PPENDIX 2: O PERA T OR ID C ODES This appendix provides a list of operator codes and the a ssociated operator name. Operator name Network name ID code On mobile phone Belgium Proximus Belgacom Mobil.
Operator name Network name ID code On mobile phone Spain Vodafone Es pana S.A. Vodafone 21401 E VODAF Retevision Movil S.A AMENA 21403 RET MOV, E 03, A MENA Telefonica Moviles Espana S.
www.gesecurity.com EMEA Distribution is a division of GE Security EMEA bvba COPYRIGHT ©2005 © GE Security EMEA bvba. All rights reserved. GE Securit y EMEA bvba grants the right to reprint this manual for internal use only. GE Securit y EMEA bvba reserves the right to change informa tion without notice.
デバイスGE NX-7002の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
GE NX-7002をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGE NX-7002の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。GE NX-7002の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。GE NX-7002で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
GE NX-7002を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGE NX-7002の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、GE NX-7002に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGE NX-7002デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。