Generac ® Pow er Systems, Inc. I NTRODUCTION Thank you for purchasing this model of the Guardian product line by Generac P ower Systems Inc. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads dur- ing a utility power failure.
T able of Contents Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 1 Introduction ........................Inside F ront Cover Read This Manual Thoroughly ........................IFC Contents ....................
2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained.
Generac ® Pow er Systems, Inc. 3 ELE CTR ICAL HA ZAR DS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion.
Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and r egulations.
Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 5 1.4 Y OU R GEN ER A T OR.
6 Generac ® Pow er Systems, Inc. Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.5 SP E CI F ICA TIONS 1.5.
Generac ® Pow er Systems, Inc. 7 1 . 6 FUE L RE QUIRE ME N T S AN D REC OMM EN D A TIONS With LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank.
3. The unit has been factory set to run on NG fuel. T o reset the system to run on LP fuel, turn the two adjustment screws 1/2 turn clockwise. Use a large screwdriver to make this adjustment. Be sure to replace the plastic plug in the back of the enclosure once the adjustment has been made.
Generac ® Pow er Systems, Inc. 9 NOTE: Y our generator is equipped with a battery trickle charger that is active when your unit is set up for automatic operation.
10 Generac ® Pow er Systems, Inc. 2.2 CH E CK TRANSF ER SWIT CH OP ER A TION Refer to Section 3.5 (P age 14), of the owner’s manual for manual operation procedures. Do not attempt manual transfer switch opera- tion until all power voltage supplies to the transfer switch have been positively turned off.
Generac ® Pow er Systems, Inc. 11 8. T urn ON electrical loads. Apply an electrical load equal to the full rated wattage/amperage capacity of the installed generator . 9. Connect an accurate AC frequency meter across terminal lugs E1 and E2. V oltage should be greater than 230 volts; frequency should be greater than 58 Hertz.
12 Generac ® Pow er Systems, Inc. Figure 2.2 — Placement of Regulator 7. T urn utility power to the main distribution panel back on. This can be done by switching the serv- ice main breaker to the on or closed position. Allow the generator to shut down.
Generac ® Pow er Systems, Inc. 13 Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 2.7 .3 ADDITIONAL COR ROSION P RO TECTION P eriodically spray all engine linkage parts and brack- ets with corrosion inhibiting spray such as WD -40 or a comparable product.
14 Generac ® Pow er Systems, Inc. Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting normally occurs when utility power source voltage dr ops below a pre- set level or during the normal exercise cycle.
Generac ® Pow er Systems, Inc. 15 Do not attempt to activate the transfer switch manually until all power voltage supplies to the switch have been positively turned off. Failure to turn off all power voltage supplies may result in extr emely hazardous and possibly fatal electrical shock.
16 Generac ® Pow er Systems, Inc. 3.7 P RO TECTION S Y S TEMS 3.7 .1 LO W OIL P R E S SU RE SWIT CH This switch (Figure 3.3) has normally closed contacts that are held open by engine oil pressure during crank- ing and operating . Should oil pressure drop below the 8 psi range, switch contacts close, and the engine shuts down.
Generac ® Pow er Systems, Inc. 17 Never operate the engine with the oil level below the “Add” mark on the dipstick. Doing this could damage the engine. 4. Install the dipstick. 5. Reset the Auto/Off/Manual switch to its original position. Figure 4.
18 Generac ® Pow er Systems, Inc. 4.5 CHANGI NG THE ENGI N E AI R CLEANER 4.5.1 7 KW , 1 2 KW AN D 1 5 KW GEN ERA T ORS See Figures 1.2 and 1.3, (P age 5), for the location of your air cleaner . Use the following procedure (Figure 4.6): 1. T urn the two screws counterclockwise to loosen.
Generac ® Pow er Systems, Inc. 19 • Remove watches, rings or other metal objects; • Use tools with insulated handles; • Wear rubber gloves and boots; • Do not lay tools or metal parts on top of the battery; and • Disconnect charging sour ce prior to connecting or dis- connecting battery terminals.
20 Generac ® Pow er Systems, Inc. Figure 4.10 - V alve Clearance Adjustment • Install new valve cover gasket. • Re -attach the valve cover . NOTE: Start all four screws before tightening or you will not be able to get all the screws in place. Make sure the valve cover gasket is in place.
Generac ® Pow er Systems, Inc. 21 4.1 2 OUT OF SERVICE P ROCEDUR E 4.1 2.1 R EMO V AL F ROM SERVICE If you cannot exercise the generator every seven days, and it is to be out of service longer than 90 days, pre- pare the generator for storage as follows: 1.
22 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by your nearest Generac/Guar dian Authorized Dealer .
Generac ® Pow er Systems, Inc. 23 Section 5 — T roubleshooting Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5.1 TROU B LE SHOO TI NG GU I DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown 1. Replace fuse. 2. Loose, corroded or defective 2.
24 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 12 & 15 k W – Drawing No.
Generac ® Pow er Systems, Inc. 25 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 12 & 15 k W – Drawing No.
26 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 12 & 15 k W – Drawing No.
Generac ® Pow er Systems, Inc. 27 Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 12 & 15 k W – Drawing No.
TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.) ENGINE WIRING IM - IGNITION MODULE LOP - LOW OIL PRESSURE SWITCH SP - SPARK PLUG SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH.
Generac ® Pow er Systems, Inc. 29.
IM - IGNITION MODULE LOP - LOW OIL PRESSURE SWITCH SP - SPARK PLUG SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH SM - STARTER MOTOR TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.
Generac ® Pow er Systems, Inc. 31 2 15 34 J2 2 1 3 2 1 8 14 16 17 15 11 13 12 10 9 J1 7 5 6 3 4 2 1 229 224A 239 15A 0 15 18 240V IM 0 15 194 13 17 17 15B 15 23 15 239 SW1 194 178 15A 229 N1 N2 183 2.
32 Generac ® Pow er Systems, Inc..
Generac ® Pow er Systems, Inc. 33 ITEM P ART NO . QTY . DESCRIPTION 1 0C6140 1 ASSEMBL Y , ENCLOSURE BASE (12KW / 15KW) 0D1901 1 ASSEMBL Y , ENCLOSURE BASE (7KW) 2 0C6735 2 SUPPORT , ROOF FOLDING 3 0.
34 Generac ® Pow er Systems, Inc. 21 23 17 22 17 37 38 8,32 8,9 27 4 16 24 10 13 19 14 15 35 11 25 17 31 14 15 5 34 16 23 36 39 38 16 31 23 2 28 29 21 17 16 4 6 7 31 23 27 42 12 45 44 20 40 33 1 43 1.
Generac ® Pow er Systems, Inc. 35 ITEM P ART NO . QTY . DESCRIPTION 1 0A9947E 1 CIRCUIT BREAKER 30 X 2 240V SQD QOU230 (7KW) 0A9947F 1 CIRCUIT BREAKER 50 X 2 240V SQD QOU245 (12KW) 0A9947C 1 CIRCUIT .
36 Generac ® Pow er Systems, Inc. 30 1 29 23 16 27 9 22 22 21 16 23 24 10 31 7 9 17 18 4 6 11 5 3 2 39 40 4 36 19 25 15 26 38 33 32 34 34 35 12 37 14 8 13.
Generac ® Pow er Systems, Inc. 37 ITEM P ART NO . QTY . DESCRIPTION 1 0D4801 1 BO X GTS LO AD CENTER 2 0D4800 1 CO VER, 8 POSITION GTS LO AD CENTER 3 0C2237 1 TRANSFER SWITCH HOME ST ANDBY 100A2P250V 4 074908 6 SCREW T APTITE M5-0.
38 Generac ® Pow er Systems, Inc. 30 1 29 23 16 27 9 22 22 21 16 23 24 10 31 7 9 17 18 4 6 11 5 3 2 39 40 4 36 19 25 15 26 38 41 33 32 34 34 35 42 37 12 14 8 13.
Generac ® Pow er Systems, Inc. 39 ITEM P ART NO . QTY . DESCRIPTION 1 0D3086 1 BO X GTS LO AD CENTER 2 0D3092 1 CO VER, 12 POSITION GTS LO AD CENTER 3 0C2237 1 TRANSFER SWITCH HOME ST ANDBY 100A2P250V 4 074908 6 SCREW T APTITE M5-0.
40 Generac ® Pow er Systems, Inc. 17 16 15 18 21 22 14 13 12 9 7 8 31 24 3 27 29 28 32 19 23 6 5 64 63 62 61 60 59 58 57 52 51 50 49 48 47 46 45 44 43 53 54 55 56 1 42 41 38 37 36 35 34 33 39 3 3 40 .
Generac ® Pow er Systems, Inc. 41 ITEM P ART NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0C3008 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 8 SCREW , T APTITE M6-1.
42 Generac ® Pow er Systems, Inc..
Generac ® Pow er Systems, Inc. 43 ITEM P ART NO . QTY . DESCRIPTION 73 0C5136A 2 KNOB, AIR CLEANER 74 0C3024 1 CO VER, AIRBO X NG/LP 75 0C3040 1 PRE-CLEANER, 76 0C8127 1 ELEMENT , AIR CLEANER 77 0C7720 1 MIXER / AIRBO X, ASSEMBL Y 78 0D2595 4 SCREW SHOULDER (8MM) M6-1.
44 Generac ® Pow er Systems, Inc..
Generac ® Pow er Systems, Inc. 45 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No.
46 Generac ® Pow er Systems, Inc. 36 35 36 37 6 34 7 8 21 38 9 3 2 1 4 5 23 11 24 31 12 25 22 14 20 38 15 30 24 26 32 10 19 16 28 27 17 10 19 32 28 31 32 17 32 31 33 29 28 13 28 39 18 10 40 29 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No.
Generac ® Pow er Systems, Inc. 47 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No.
48 Generac ® Pow er Systems, Inc. 11 47 33 34 36 35 37 27 45 43 39 18 19 20 23 32 44 48 24 46 11 22 29 28 31 30 17 52 1 14 13 26 38 25 25 40 41 12 21 15 16 6 1 2 4 42 10 5 7 3 8 9 49 51 50 54 53.
Generac ® Pow er Systems, Inc. 49 ITEM P ART NO . QTY . DESCRIPTION 1 071978 1 ASSEMBL Y , CONNECTING ROD 2 071980 1 PIN, PIST ON D20 3 021533 1 SET , PIST ON RING 90MM 4 0C5848 1 PIST ON, HC 5 07198.
50 Generac ® Pow er Systems, Inc..
Generac ® Pow er Systems, Inc. 51 ITEM P ART NO . QTY . DESCRIPTION 1 0C1069 5 SCREW , T APTITE M6-1.0X8 YELLO W CHROME 2 0D2922 1 HOUSING, BLOWER 3 0C8435 1 TUBE, DIPSTICK 4 0C9997 1 GUARD , F AN 5 .
ITEM P ART NO . QTY . DESCRIPTION 1 0C5322 1 CASTING, TWIN REGULA TOR HOUSING 2 0C5765 1 SOLENOID , TWIN REGULA T OR 3 0C4647 1 GASKET , SOLENOID 4 0C4680 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0C6070 1 SPRING-SOLENOID , PLUNGER 6 022985 4 WASHER, FLA T #6 7 022264 4 WASHER, LOCK M4 8 075475 4 SCREW PPHM M4-0.
Generac ® Pow er Systems, Inc. 53 Section 8 — Notes Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators.
54 Generac ® Pow er Systems, Inc. Section 8 — Notes Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators.
Generac ® Pow er Systems, Inc. 55 Section 9 — Mounting Dimensions Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Drawing No. 0D3 7 3 9-A TYPE HOM TYPE HOM 120/240v 120/240v CBHOM-F CBHOM-F.
56 Generac ® Pow er Systems, Inc. CALI FORN IA EM IS SION C ONTROL W AR R ANTY ST A TEM ENT Y OU R W AR R ANT Y RIGHTS AND OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine.
Generac ® Pow er Systems, Inc. 57 EM IS SION C ONTROL SY S TEM W ARR ANTY Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines.
GEN ERAC PO WER S YS TEMS "TWO YEAR" S T AN D ARD W ARR ANT Y FOR GUARDIAN ® "P REP ACKAGED EMERGENCY AUT OMA TIC ST AN DB Y GEN ERA T ORS" F or a period of two years or 2000 hours of operation from the date of original sale, whichever occurs first, Generac P ower Systems, Inc.
デバイスGenerac 04389-0, 04456-0, 04390-0の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Generac 04389-0, 04456-0, 04390-0をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGenerac 04389-0, 04456-0, 04390-0の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Generac 04389-0, 04456-0, 04390-0の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Generac 04389-0, 04456-0, 04390-0で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Generac 04389-0, 04456-0, 04390-0を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGenerac 04389-0, 04456-0, 04390-0の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Generac 04389-0, 04456-0, 04390-0に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGenerac 04389-0, 04456-0, 04390-0デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。