GeneracメーカーQT06024AVSXの使用説明書/サービス説明書
ページ先へ移動 of 76
This manual should remain with the unit. 2.4L 60kW Models EP A Cer tified Owner's Manual Stationar y Emergency Generator Cover195 Re v . A 04/10 Part No.
SECTION P AGE INTRODUCTION ........................................................... 1-1 Read this Manual Thoroughly ....................................................... 1-1 Operation and Maintenance ..............................................
INTRODUCTION Thank you for purchasing this model of the stationar y emergency generator product line. Ever y effor t was expended to make sure that the infor mation and instr uctions in this manual were both accurate and current at the time the manual was written.
SAFETY RULES Study these SAFETY RULES carefully before installing, operating or ser vicing this equipment. Become familiar with this Owner ’s Manual and with the unit. The generator can operate safely , effi- ciently and reliably only if it is properly installed, operated and maintained.
If personnel must stand on metal or concrete while installing, • operating, ser vicing, adjusting or repairing this equipment, place insulative mats over a dr y wooden platform.
IDENTIFICA TION RECORD DA T A L ABEL Ever y generator set has a DA T A L ABEL that contains impor tant information per tinent to the generator . The data label, which can be found attached to the gene.
EQUIPMENT DESCRIPTION This equipment is a revolving field, alternating cur rent Stationar y Emergency Generator . It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units.
ENGINE PROTECTIVE DEVICES The Stationar y Emergency Generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant temperature, oil pressure or rpm.
FUEL SYSTEM FUEL REQUIREMENTS The Stationar y Emergency Generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (LPV) fuel system Recommended fuels should have a Btu content of at least 1,000 Btu's per cubic foot for natural gas; or at least 2,520 Btu's per cubic foot for LP gas.
SPECIFICA TIONS GENERA TOR T ype...................................................................... Synchronous Rotor Insulation ............................................................. Class H Stator Insulation ...............................
WEA THER AND MAINTENANCE KITS T o keep the generator r unning at its peak, the following kits are offered: Cold Weather Kit • ~ Recommended for climates with temperatures below 32° F . Extreme Cold Weather Kit • ~ Recommended Block Heater Kit for protection in tempera- tures below 32° F .
AL TERNA TOR AC LEAD CONNECTIONS The electrical wires in the unit’s AC connection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application. The voltage and phase are described on the generator data label.
Figure 7.4 — Stator P ower Winding Connections - 3-phase, 120/208V (6 Lead) E3 E2 00 (NEUTRAL) INTERNAL CONNECTIONS E1 L-L L-N S1 S1 S4 S4 S6 S6 S3 S3 S5 S5 S2 S2 Figure 7.5 — Stator P ower Winding Connections - 3-phase, 120/208V (12 Lead) E3 E2 E1 L-L L-N S7 S1 S10 S4 S12 S6 S9 S3 S5 S11 S2 S8 Figure 7.
CONTROL P ANEL INTERF ACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to A UTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source voltage drops below a preset level or during the normal exercise cycle.
8-2 CntrlNexus001 Rev . D 04/11 Control P anel ACTIVA TION CHART CHOOSE LANGUAGE TROUBLESHOOTING Display Reads: Use ARROW keys to scroll to desired lan- guage. Press ENTER to select. If the wrong language is chosen, it can be changed later using the “edit” menu.
INST ALLA TION ASSIST ANT Interconnect System Self T est Feature (follow the on-screen prompts). Upon power up, this controller will go through a system self test which will check for the presence of utility voltage on the DC circuits.
SEQUENCE OF AUTOMA TIC OPERA TION Initial Conditions: Generator in Auto ready to r un, load being sup- plied by the Utility Source through the transfer switch. 1. When the utility voltage fails (falls below 60% of nominal), a 10-30 second (programmable) “line interr upt” delay timer is star ted.
CHECK ENGINE MESSAGE The control system has detected an emissions related fault. This fault cannot be cleared using the control panel inter face. The unit will continue to operate in automatic mode.
OVERVOL T AGE AL ARM If the generator voltage rises above 110% for >3 seconds, an alarm will be issued. If the generator voltage rises above 130% for >0.2 seconds, an alarm will be issued. INTERNAL F AILURE SHUTDOWN ALARM Any internal failure that can be detected such as cor r upted firmware will cause this shutdown alar m.
MAINTENANCE ALERT CHART CONDITION 1.6 CHERY 2.4/1800 MITSU 2.4/3600 MITSU 4.2 FORD Change oil & filter aler t 3mo/30hrs break-in 1yr/100hrs 3mo/30hrs break-in 1yr/100hrs 3mo/30hrs break-in 1yr/100.
8-8 CntrlNexus001 Rev . D 04/11 Control P anel ACTIV A TION RUN LOG ALARM LOG HISTOR Y STA TUS COMMAND S TAT E VERSIONS DISPLA Y GENERA TOR FREQUENCY ENGINE HOURS ENGINE RPM BA TTERY VO LTA G E DEBUG INPUTS OUTPUTS DISPLA YS EDIT LANGU AGE TIME/DA TE EXERCISE TIME/SPEED ESC Press the “ESCAPE” key to jump back up through the menu levels.
ST A TIONARY EMERGENCY GENERA TOR CONTROL AND OPERA TION Refer to the appropriate control panel operator’s manual for this unit. OPERA TING UNIT WITH MANUAL TRANSFER SWITCH If the Stationar y Emergency Generator was installed in conjunction with a transfer switch capable of manual operation only , the fol- lowing procedure applies.
GENERAL MAINTENANCE Before working on the Stationary Emergency Generator , ensure the following: The AUTO/OFF/MANUAL switch is in the OFF position. • The control panel fuse has been removed from the control • box. The 120VAC supply to the battery charger is switched OFF .
ENGINE COOLANT Check coolant level in coolant recover y bottle. See the Specifications and Ser vice Schedule sections. Add recommended coolant mixture as necessar y . • P eriodically remove radiator pressure cap (only when engine • has cooled down) to make sure the coolant recover y system is functioning properly .
Figure 10.3 – Engine Air Filter Air Filter SP ARK PLUGS Reset the spark plug gap or replace the spark plugs as neces- sar y . 1. Clean the area around the base of the spark plugs to keep dir t and debris out of the engine. Clean by scraping or washing using a wire br ush and commercial solvent.
SERVICE SCHEDULE System / Component Frequency Procedure Weekly - W Monthly - M Y early - Y Inspect Change Clean Fuel Fuel Lines & Connections M X Lubrication Oil Level M X* Oil Y X** Oil Filter Y .
T roubleshooting TROUBLESHOOTING GUIDE PROBLEM C AUSE CORRECTION Engine won’t crank. 1. Control panel 7.5 amp fuse blown. 1. R eplace fuse.* 2. Loose or corroded or defective 2. Tighten, clean or replace batter y cables. batter y cables as necessar y .
.
1 0F9677 1 ROTOR-2390 -45KD1 CPL 0G0056 1 ROTO R -2 390-35KD1 CP L 0G0959 1 ROTO R -2 390-45KD1 CP L (G 2) 0G1155 1 ROTO R -2 390-35KD1 CP L (G 2) 0G1931 1 ROTO R 25 KW 3PH DIREC T 390 1800 0G2101 1 R.
.
.
.
EXPLODED VIEW: CO NBOX C2 CP L DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-9621-F Page 4 of 8 DATE: 9/26/11 ITEM P ART# QTY. DES CRIP TION 1 0H6266 1 BA CK PANEL CONBOX SUPPO RT C2 2 0H6265 1.
EXPLODED VIEW: CO NBOX C2 CP L DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-9621-F Page 5 of 8 DATE: 9/26/11 ITEM P ART# QTY. DES CRIP TION UL CIRCUIT BREAKER (225A F) A 0G5250 1 CB 175A 2 POL.
EXPLODED VIEW: CO NBOX C2 CP L DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-9621-F Page 6 of 8 DATE: 9/26/11 ITEM P ART# QTY. DES CRIP TION UL CIRCUIT BREAKER ( KG) A 0H5582 1 CB 0300 3P 600V E KG LL B 0H6740 1 COVER CB E KG C2 CONBOX C 0D3700 4 NUT FLANG E M6-1.
EXPLODED VIEW: CO NBOX C2 CP L DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-9621-F Page 7 of 8 DATE: 9/26/11 ITEM P ART# QTY. DES CRIP TION UL CIRCUIT BREAKER (QN) A 0E7284 1 CB 0175A 2P 240V .
EXPLODED VIEW: CO NBOX C2 CP L DRAWING #: 0H7326 GROUP A APPLICABLE TO: REVISION: H-9621-F Page 8 of 8 DATE: 9/26/11 THIS PAGE LEFT INTENTIONALLY BLANK.
.
1 0G37260ST03 1 WELDMENT FRAME 2.4L C2 60KW 2 05286 0 4 NUT FL A NGE D HEX M12-1.75 3 05225 1 4 DAMPENE R VIBRATION 40 BLUE 4 05225 7 4 SPACER .4 9 X . 62 X 1 .87 PWDR/ZNC 5 05225 2 4 DAMPENE R VIBRATION 6 05225 9 4 WASHE R FLAT M12 7 05289 1 4 SCREW HHC M12-1.
.
1 0F3408C 1 BATTERY TRAY, C1 & C2 2 0F3411 1 S T RAP BAT TERY RETAINME NT 3 02550 7 REF WASHER SHAKEP ROOF EXT 7/16 STL 4 05221 2 REF SCREW HHC M 10 -1 .
.
EXPLODED VIEW: AIR CL EANER 2.4 L G2 TUR B O DRAWING #: 0H1954 GROUP D APPLICABLE TO: REVISION: H-3963 –B PAGE 2 OF 2 DATE: 2/27/09 ITEM PART# QTY. DESCRIPTION 1 0F4269 2 GA S KET MIXER BODY 2 0H0030 1 ADAPTOR-MIXER 3 0G39340ST03 1 B RACK ET AIR INTAKE 4 035480 1 BOLT U 5/16-18 X 2.
.
.
1 0H30830ST03 1 WELDMENT RADIATO R SUP PORT C2 2 0F2608 1 RADIATOR 598 X 568 X 49 CPL RH 3 0F5263 1 V-BELT 31/64" X 57- 3/8" 4 04652 6 5 WASHE R LOCK M1 0 (1) 5 0599 81 4 SCREW HH C M10-1.
.
.
EXPLODED VIEW: T URBO 2.4L G2 DRAWING #: 0H3356 GROUP D APPLICABLE TO: REVISION: -A- PAGE 1 OF DATE: 6/22/09 ITEM PART# QTY. DESCRIPTION 1 042574 1 ADAPTER 1/8NPTF TO 1/8 BSPT 2 064094 1 MALE E L BOW 45 #49X 3 3 064096B 1 OI L SUPPLY 3LHA(38") 4 0G8690 1 GASKET 2.
.
EXPLODED VIEW: MUFFLER EXH 2.4 L G2 TURBO DRAWING #: 0H3357 GROUP F APPLICABLE TO: REVISION: H-5192-B PAGE 1 OF DATE: 10/12/09 ITEM PART# QTY. DESCRIPTION 1 0G86870ST03 1 BRACKET MUFFLER 2 0G8686 1 BR.
.
.
EXPLODED VIEW: ENG I NE COMMON P ARTS 2.4L G2 TURBO 60K DRAWING #:0H7323 GROUP D APPLICABLE TO: REVISION: H-7244-D Page 3 of 4 DATE: 8/10/10 ITEM PART# QTY. DESCRIPTION 1 0H1619 1 ENGINE 2.4L G2 CERTIFIED 2 035472 1 CLAMP HOSE #6 .43-.78 3 0G1 738 1 CAP ANTIFREEZE RUBBER 9.
EXPLODED VIEW: ENG I NE COMMON P ARTS 2.4L G2 TURBO 60K DRAWING #:0H7323 GROUP D APPLICABLE TO: REVISION: H-7244-D Page 4 of 4 DATE: 8/10/10 ITEM PART# QTY. DESCRIPTION 66 0G8853 4 COIL- 2.4L G2 IGNITION 67 023897 8 W ASHER FLAT #10 ZI NC 68 022152 8 W ASHER LOCK #10 69 034413 8 S CREW HHM #10-32 X 1-1/4 70 0G9350 1 O- RING 2.
.
1 057147 1 HOSE 3/4 I D LPG & NG (43”LG) 2 065908 1 FLANGE F UEL IN L ET 3 039130 1 NIPPLE C LO SE 1.25 NPT X 1.625 4 030131 1 ELBOW 9 0D 1- 1/4 NPT 5 088963 1 NIPPLE PIPE 1.25 NPT X 5.5 BL I R N 6 026915 2 NIPPLE C LO SE 3/4 X 1.375 7 0A8064 2 BSHG R DCR HEX 1-1/4-3/4 8 064346 1 PIPE TEE 1 -1/ 4 NPT 9 0G9239C 1 RE G ASSY 2 .
.
1 057147 1 HOSE 3/4 I D LPG & NG (45”LG) 2 075580 1 FLANGE, F U EL IN LET 3 026915 1 NIPPLE C LO SE 3/4 X 1.375 4 026812 2 ELBOW 9 0D 3/4NP T 5 0F8379 1 NIPPLE PIPE 3 /4 NPT X 7 6 026915 2 NIPPLE C LO SE 3/4 X 1.375 7 022097 4 WASHER LOCK M6-1/4 8 0F3691 1 VENTURI THRO TT LE 32MM 9 0G9189C 1 RE G ASSY 2 .
.
(2) 1 0G80180AL0R 1 R EAR WRAP C2 G2 60KW 2 0C2454 58 SCREW T HF M6- 1 X 16 N W A Z/JS (2) 3 0F58490AL0R 2 DOOR C2 4 087233 2 RIVET POP . 1875 X .450 SS 5 0E3257 4 SCREW TH-FRM M6 W/CAP SHKP RF W (2) 6 0F58520AL0R 2 DUCT DSC H RG LH&RH (2) 7 0F98330AL0R 2 FRONT COR N ERS C2 (2) 8 0F58510AL0R 1 DUCT DISC H ARGE C 2 9 049813 2 NUT HEX M 6 X 1 .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
BackPg001 Re v . A 04/07.
デバイスGenerac QT06024AVSX の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Generac QT06024AVSX をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGenerac QT06024AVSX の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Generac QT06024AVSX の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Generac QT06024AVSX で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Generac QT06024AVSX を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGenerac QT06024AVSX の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Generac QT06024AVSX に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGenerac QT06024AVSX デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。