3452535556 Included W all Control MUST be installed prior to operation of this Garage Door Operator Safe-T -Beam ® Safety Reverse System Must be installed to close door SA VE THIS MANUAL FOR FUTURE REFE RE NC E NOTE: Y our Residential Operator comes with a Rail Assembly which is standard for up to a 7 foot 6 inch high door .
6 To avoid damage to your door and/or operator , make sure you disable any door locks prior to installing your operator . 2 PRE-INST ALLA TION CHECK LIST FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM Things to consider if you are planning to “do-it-yourself.
3 7 TYPICAL SECTIONAL DOOR INST ALLA TION FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM TYPICAL SUPPORT BRACKET EXTENSION SPRING OR T ORSION SPRING SAFE-T -BEAM ® BRACES ADDED HEADER BRACKET MOUNTING.
4 SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PA G E PRE-INST ALLA TION CHECKS . . . . . . . . . . . . . . . . . . . . . . . . . . 2- 3 OPERA TOR FEA TURES . . . . . . . . . . . . . . . . . . . . . . . . .
5 RECOMMENDED TOOLS FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM 5/32" Drill Bit 7/16" and 9/16" Sockets Step ladder Drill Ratchet Carpenter ’ s level Pencil T ape measure Wire strippers Phillips screwdriver Adjustable wrench PA R TS IDENTIFICA TION - Not Shown Full Size .
6 1-PIECE RAIL HARDW ARE EXPLODED VIEW FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM [ 2 ] 3-PIECE RAIL HARDW ARE EXPLODED VIEW [ 4 ] 10 3 9 11 25 15 16 23 28 17 27 25 26 42 24 20 12 18 47 22 9 10 41 .
Power Head Assembly 1J 1N 1X 1L 1N 1E 1K 1D 1A 1N 1H 1B 1Q 1G 1D 1F 49 1P 1M 1N 7 Item Part Name Number Required 1 pc. rail 3 pc. rail 1P ower head assembly (box) 11 2R ail assembly (1-piece) (box) 1 .
FIG. 1-4 Attach rail strap . 8 OPERA T OR ASSEMBL Y FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM 1 NOTE: For 1-piece rail—skip to step 4. 1. Identify the rail sections (Fig. 1-1) . • First rail section (attaches to power head). – 2 holes each end.
FIG. 1-5 Align arro w . FIG. 1-8 Attach emer gency release cord & tag . 9 6. Attach rail to power head . • Place rail in front of power head with rail strap at opposite end. • Support door end of rail (rail strap) at about same height as power head.
10 10. Attach limit switch wires . • Uncoil limit switch wires. – Place into channels located along top of rail . – Run wires back to power head through hole in top of power head (Fig. 1-12) . – Use wire clips to hold wires in place (Fig. 1-13) .
FIG. 2-1 Finding highest point of travel (sectional) . 11 INST ALLA TION FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM 2 IMPORT ANT 1. READ AND FOLLOW ALL SAFETY , INST ALLA TION AND OPERA TION INSTRUCTIONS. If you have questions or do not understand an instruction, call The Genie Company or an authorized Genie Dealer .
12 NOTE: If header bracket location needs to be above header for garage door opening, you need to add a “mounting surface.” A 2" x 6" board securely attached (fasteners not included) across wall studs on either side of your mark is sufficient (Fig.
Mounting Straps [22] 13 MOUNTING THE OPERA T OR: 1. Getting Started . • Position rail/power head assembly (Fig. 2-7) . – Rail strap leaning on wall next to header bracket. – Place material on floor under power head to protect from scratching. (A box, stool, or similar device may be needed to clear a torsion spring, as shown.
INST ALL DOOR ARMS: Sectional doors OPEN YELLOW P ARTS BAG 1. Attach the arms . • Fasten curved door arm to door bracket using clevis pin (24) and cotter pin (25) (Fig. 2-10) . • Straight arm to carriage using clevis pin (24) and cotter pin (25) (Fig.
3. Wiring . • Route wire (29) using either method shown (Fig. 3-5) . • Wires along rail are held in place with wire clips. – Wires can be slipped under the wire clips already in place. 15 SAFE-T -BEAM ® SYSTEM INST ALLA TION FOR HELP-1.800.354.
FIG. 3-8 T erminal attachments at power head . OPEN RED P ARTS BAG 3. Wiring (cont’) . • Securely fasten wires to wall as you go. – Use insulated staples (included). – Staples should be snug only . 16 • Make wire attachments at “ STB ’ s.
FIG. 5-1 T erminal attachments at power head . W ALL CONTROL INST ALLA TION FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM 4 1. Finding the mounting location . • Pick a convenient location for mounting wall control. – Location you choose should be in direct sight of door .
18 CONNECTING TO POWER FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM 5 1. Plug the operator into a properly grounded electrical outlet . 2. Check Safe-T -Beam ® alignment (Fig. 6-3) . To reduce the risk of electrical shock, this equipment has a grounded type plug that includes a third ( grounding ) pin.
19 LIMIT SWITCH / FORCE ADJUSTMENT FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM 6 NOTE: During operator cycling for force adjustment, the motor protector may shut off power to the operator . If this occurs, wait about 20 minutes to allow the motor protector to reset.
FCC and IC CER TIFIED 20 PROGRAMMING REMOTE CONTROLS 7 FIG. 8-1 Learn code button and LED 1. Programming . • Locate learn code button and indicator LED on front of power head (under force adjustment screws) (Fig. 8-1) . • Press and release learn code button.
21 MUL TI-BUTT ON REMOTE 1. Programming . NOTE: Each button on a multi-button remote is designed for use with 1 door . Y ou cannot pro- gram 2 buttons to operate the same door , nor can you program 1 button to operate 2 doors. • For each button . – Program each button separately .
22 IMPORT ANT SAFETY INSTRUCTIONS 1. READ AND FOLLOW ALL INSTR UCTIONS. 2. Nev er let children operate or pla y with the door controls . K eep the remote control a wa y from children. 3. Alwa ys keep the mo ving door in sight and a wa y from people and objects until the door is completely closed.
23 TROUBLESHOOTING GUIDE (CONTINUED) FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM • Check lock switch on wall console. • Check power source. – Plug a lamp into outlet used for power head If lamp works, power source is OK. – If not, check fuse or circuit breaker .
24 WIRING DIAGRAM FOR HELP-1.800.354.3643 OR GENIECOMP ANY .COM Tr ansmitters comply with all United States and Canadian legal requirements as of the date of manufacture . No warranty is made that they comply with all legal requirements of an y other jurisdiction.
A No C .O.D . shipments. Please include chec k or money order , do not send cash. Allow 3-4 weeks f or deliv er y . We accept Visa or Mastercard phone orders. 1.800.354.3643. Please hav e par t number and credit card ready . Please add local sales tax if y ou reside in one of the states listed.
MODEL DESCRIPTION PRODUCT CODE PRICE (US$)* QTY . TOT AL MODELO DESCRIPCIÓN CÓDIGO PRECIO* CANTIDAD TOT AL MODÈLE DESCRIPTION CODE DU PRODUIT PRIX ($ US)* QTÉ T OT AL Delux e Remote Control with Intellicode ® GIT -1 Controlador remoto de lujo con Intellicode ® 33069R $34.
C The Genie Company Professional Access Systems LIMITED W ARRANTY What is covered: Any defect in material and product workmanship from personal, normal household use in accordance with the Owner ’ s Manual. For how long: H2000C-1 Series - 3 years on Motor , and 1 year on all other parts.
デバイスGenie 3452535556 GCGの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Genie 3452535556 GCGをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGenie 3452535556 GCGの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Genie 3452535556 GCGの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Genie 3452535556 GCGで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Genie 3452535556 GCGを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGenie 3452535556 GCGの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Genie 3452535556 GCGに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGenie 3452535556 GCGデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。