GiantメーカーGP7150Aの使用説明書/サービス説明書
ページ先へ移動 of 12
Contents: Installation Instructions page 2 Pump Specifications (GP7150A): page 3 Exploded View: page 4 Parts List: page 5 Pump Specifications (GP7155A): page 6 Kits/Torque Specifications: page 7 Maint.
recommended by Giant Industries, Inc. to further reduce system pulsation. Dampeners can also reduce the severity of pressure spikes that occur in systems using a shut-off gun. A dampener must be positioned downstream from the un- loader. 5. Crankshaft rotation on Giant Industries, Inc.
U.S. . . ............................. (Metric) V olume .................................................................................... 54.5 GPM ..................... (206 LPM) Discharge Pressure ..................................................
4 Exploded V iew - GP7150A and GP7155A.
ITEM PART DESCRIPTION QTY. 1 07600 Crankcase 1 1 A 05313 Head for Oil Dipstick 1 1 B 01009 O-Ring 1 2 13000 Oil Filler Plug Assy. 1 4 07601 Crankcase Cover 1 5 07602 Gasket, Crankcase Cover 1 8 07603 .
U.S. . . ............................. (Metric) V olume .................................................................................... 65.8 GPM ..................... (250 LPM) Discharge Pressure ..................................................
REP AIR KITS - GP7150A and GP7155A Plunger Packing Kit - GP7150A # 09526 Item Part # Description Qty . 38 A 13156 O-Ring 3 3 8B 06258 O-Ring 3 38 C 07635 Support Ring 3 39 A 07796 Grooved Ring 3 42 07638 V -Sleeve 6 Plunger Packing Kit - GP7155A # 09220 Item Part # Description Qty .
8 TO CHECK VAL VES Loosen plugs (58), take out tension spring (57) and then remove the complete valve assembly (51) with either a valve tool or an M16 hexagon screw . T o remove the valve adapter (56) and tension spring (57), use a pullout tool size 5.
9 PUMP SYSTEM MA LFUNCTIONS M A LFUNCT ION CAUSE REMEDY The Press ure and/ or th e Deliver y Drops W or n pack ing s eals Replac e pac king sea ls Brok en valve spr ings R eplace spr ings Belt slippag.
GP7150A and GP7155A Dimensions - Inches (mm) 10.
11.
10/07 GP7150A_GP7155A.PMD GIANT INDUSTRIES, INC. 900 N. Westwood Ave. P.O. Box 3187 Toledo, Ohio 43607 Phone; (419) 531-4600 FAX (419) 531-6836 Copyright 2007 Giant Industries, Inc. www.giantpumps.com GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc.
デバイスGiant GP7150Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant GP7150Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant GP7150Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant GP7150Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant GP7150Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant GP7150Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant GP7150Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant GP7150Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant GP7150Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。