Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page 4 Parts List/Kits: page 5 Rep.
2 NOTE: Contact Giant Industries for Service School Information. Phone: (419)-531-4600 INSTALLATION INSTRUCTIONS Installation of the Giant Industries, Inc., pump is not a complicated procedure, but there are some basic steps common to all pumps. The following information is to be considered as a general outline for installation.
3 Specifications Model LP122A-3100 Pump speeds of 640 RPM and above require a minimum inlet pressure of 12 psig. U.S. ................. Metric V olume .............................................................................. 35.6 GPM ........ 134.
4 Exploded View - LP122A-3100.
5 ITEM PART NO. DESCRIPTION QTY. 1 07759 Crankcase 1 2 13000 Oil Filler Plug 1 4 06085 Crankcase Cover 1 5 07104 O-Ring 1 6 07186 Oil Sight Glass W/Gasket 1 8 06086 Oil Dipstick 1 9 01009 O-Ring 1 1 0.
6 LP122A-3100 - Repair Instructions 1. With a 30mm wrench, re- move the six (6) plugs (48) from the valve casing (43). Inspect the o-rings (48A) and replace if necessary. Remove the complete valve assembly (46A) by thread- ing a 12mm bolt into the spring retainer and pulling straight out.
7 8. If previously disassembled thoroughly clean all exposed surfaces on the spacer (29E) and all exposed threads on the plunger bolt (29C) and the steel plunger base (25). Threads MUST be free of old loc-tite and any other material such as oil, grease, etc.
8 11. Press seal sleeve assembly into the manifold and seat firmly. Put the support ring (41) on plunger with v-side facing the manifold. 1 2 . Place entire manifold/seal sleeve assembly over the studs and push firmly until seated against the crankcase.
9 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace .
10 Position Item# Description Torque Amount 10 08093 Screw, Cover 125 in.-lbs. 17 08095 Hex Screw, Bearing Cover 125 in.-lbs. 24A 13277 Hex Screw, Connecting Rod 250 in.-lbs. 29C 07131-0100 Plunger Bolt 26 ft.-lbs. 48 06077-0100 Plug, Valve 160 ft.-lb s.
11 LP122A-3100 DIMENSIONS - INCHES (mm).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period.
デバイスGiant LP122A-3100の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant LP122A-3100をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant LP122A-3100の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant LP122A-3100の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant LP122A-3100で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant LP122A-3100を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant LP122A-3100の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant LP122A-3100に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant LP122A-3100デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。