GiantメーカーP300の使用説明書/サービス説明書
ページ先へ移動 of 16
Series P 300 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: page 2 Pump Specifications: pages 3-7, 10 Exploded View: page 8 Parts L.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
4 Specifications Model P316 U.S. (Metric) 1450 RPM Ratings (Continuous) .................................... 4.4 GPM @ 3000 PSI ..... (16.7 LPM @ 200 bar) Ratings (Intermittent) .................................... 4.4 GPM @ 3500 PSI ..... (16.7 LPM @ 240 bar) 1750 RPM Ratings (Continuous) .
5 Specifications Model P317 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
NPSHR (FT -HEAD) 50 68 86 104 122 140 158 176 194 212 230 0 F 69.0 66.0 62.3 59.0 56.8 52.5 49.2 46.0 43.0 39.3 36.0 33.0 30.0 26.2 1 7 3 0 R P M 6 . 2 2 G P M 1 4 2 0 R P M 5 1 G P M P318 NPSHR Chart P318 HORSEPOWER REQUIREMENTS RPM GPM 750 PSI 1000 PSI 1500 PSI 1750 PSI 2000 PSI 810 3.
P319 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI* 3000 4.2 4.3 5.8 7.2 8.7 3200 4.5 4.7 6.2 7.8 9.3 3450 4.8 5.0 6.6 8.3 9.9 7 Specifications Model P319 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
8 Exploded View - P300 Series.
9 P300 SERIES PAR TS LIST ITEM PART NO. DESCRIPTION QTY. 1 08326 Crankcase 1 2 06773 Dipstick Assembly 1 3 08410B Crankcase Cover, Short 1 3 08410-LG Crankcase Cover, Extended 1 3 A 07190 Oil Drain Pl.
P340 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI 3500 PSI 4000 PSI* 745 1.5 1.6 2.1 2.6 3.1 3.6 4.1 1025 2.0 2.1 2.8 3.4 4.1 4.8 5.5 1340 2.7 2.8 3.7 4.7 5.6 6.5 7.4 1450 2.9 3.0 4.0 5.0 6.0 7.0 8.0 1750 3.5 3.6 4.8 6.0 7.2 8.
11 Position Item# Description T or que Amount 3 B 08410/07190 Oil Drain Plug w/ Gasket 222 in.-lbs. 6 07188/1196 Screw 43 in.-lbs 1 0 7225 Screw with Lock W asher 85 in.-lbs. 1 6 C 08456 or 08450 T ension Screw , Plunger 220 in.-lbs. 3 4 08363 Hex Head Cap Screw , V alve Casing 222 in.
PUMP SYSTEM MALFUNCTION 12 PUM P SYST EM M A L FUNC TION S MALFUN CTION CAU SE REM EDY The Pressu re and/ or t he Deliver y Dro p s W orn pac k ing se als Re pl ac e pac k ing se als Brok en valve spr.
13 REPAIR INSTRUCTIONS - P300 SERIES NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.
14 11. Inspect o-rings (#21 and 22) and replace as necessary. 9. Remove the pressure rings (#24) and grooved seals (#23) from the valve casing (#26). Inspect parts for wear and replace if necessary. For P318 only, the spacers (#23A) can now be removed.
15 Reassembly sequence of the P300 Series pump REPAIR INSTRUCTIONS - P300 SERIES 14. If the oil seals (#19) were removed, replace them with the primary seal lip (grooved side) towards the crankcase and the dust lip (tapered end) towards the valve casing (#26).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
デバイスGiant P300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant P300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant P300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant P300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant P300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant P300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant P300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant P300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant P300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。