GiantメーカーTriplex Ceramic Plunger Pumpの使用説明書/サービス説明書
ページ先へ移動 of 12
Contents: Installation Instructions: page 2 Pump Specifications: page 3-4 Kits/Torque Specs: page 5 Exploded View: page 6 Parts List: page 7 Trouble Shooting: page 8 Repair Instructions: page 9-11 Dim.
2 INST ALLA TION INSTRUCTIONS - P46W , P46W -HK, & P46HT 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 P4 6W & P46W-H K PU LLEY SELECTION & H ORSEPO WER R EQ U I R EMEN TS PU MP PULLEY MO T O R PULLEY RPM G P M 1000 PSI 1500 PSI 1 700 PSI 2200 P SI 7. 75" 3. 55" 745 2.0 1. 4 2. 1 2. 3 3.0 7. 75" 4. 25" 910 2.5 1. 7 2. 6 2.
4 P4 6HT PULLEY SELEC TION & H O RSE POWER R EQUI REMEN T S PU M P PULLEY MO T O R PULLEY RPM GPM GPM 200 PSI 400 P SI 600 PSI 900 PSI 7. 75" 2.0" 385 0. 9 54. 0 0.1 0.2 0. 4 0 .6 7. 75" 3. 25" 676 1. 6 96. 0 0.2 0. 4 0. 7 1 .0 7.
5 Ceramic Plunger Assembly Kit #09082 Item Part # Description Qty . 24A 07021 Ceramic Plunger 3 24 B 08456 T ension Screw 3 24C 07676 Copper Ring 3 25 06648/13333* Flinger 3 * p/n 13333 is needed for older P46W pumps with brass retainers (p/n 08064).
6 Exploded View - P46W , P46W -HK, P46HT.
7 P46W , P46W -HK & P46HT P ARTS LIST ITEM PART DESCRIPTION QTY. 1 07222 Crankcase 1 2 07181 Vent/Filler Plug with Seal 1 2A 07182 Gasket, Oil Filler Cap 1 3 08004 Cover, Crankcase 1 4 08005 O-Rin.
8 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace .
9 1. With a 22mm socket, remove the three discharge (43) and three inlet (41) manifold plugs. Check o-rings (42 & 44) for wear and replace as necessary. 3. Use a small slide hammer to remove valve seats (37) from manifold (29). Inspect valve plates (36) and valve seats (37) for wear.
10 9. The rear V-sleeve housing (48) may be removed by prying evenly outward with a flat screwdriver. After slipping housing over plunger, inspect seals (50) and O-ring (49) and replace as necessary.
11 Gear End Disassembly 14. Remove the crankcase cover bolts (9). Inspect the crancase cover O-ring (4) for wear . Replace if necessary . 15. Inspect the dip stick (5) vent hole for signs of clogging. Clean if necessary . 16. T o remove the crankshaft (18), first remove the bearing cover plates (12) Remove the key (19).
GIANT INDUSTRIES, INC. , 900 N. Westwood Ave., P.O. Box 3187, Toledo, Ohio 43607 Phone: (419) 531-4600 FAX (419) 531-6836, www.giantpumps.com Ó Copyright 1998 Giant Industries, Inc.
デバイスGiant Triplex Ceramic Plunger Pumpの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Giant Triplex Ceramic Plunger Pumpをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGiant Triplex Ceramic Plunger Pumpの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Giant Triplex Ceramic Plunger Pumpの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Giant Triplex Ceramic Plunger Pumpで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Giant Triplex Ceramic Plunger Pumpを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGiant Triplex Ceramic Plunger Pumpの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Giant Triplex Ceramic Plunger Pumpに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGiant Triplex Ceramic Plunger Pumpデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。