INST ALLA TION AND OPERA TING INSTRUCTIONS FOR VENT -FREE OR VENTED INST ALLA TIONS GOLDEN BLOUNT “TEXAS FLAME II” GAS LOGS N A TURAL GAS OR L.P . 18“ - 24“ & 30“ SIZE SETS The Golden Blount vent-free gas log sets comply with the National Saf ety Standards and are tested and design cer tified b y CSA to ANSI Z21.
IMPOR T ANT! Read all instructions carefully bef ore starting installation. F ailur e to follo w these instructions may result in pr operty damage, personal injury or possible loss of life SAFETY AND GENERAL INFORMA TION • Use correct gas type for y our appliance.
CAUTION SET SIZE FIREPLA CE WIDTH DEPTH OPENING HEIGHT FRONT BA CK 18" 24" 18" 14" 20" 24" 30" 21 1/2" 16" 21" 30" 36" 30" 16" 21" NO TE! CARBON MONO XIDE POISONING MA Y LEAD T O DEA TH.
BURNER SYSTEM INST ALLA TION Model GB-TFII-18 GB-TFII-18 GB-TFII-24/30 GB-TFII-24/30 Gas T ype Natural L. P . Natural L. P . Max Input 30,000btu/hr 30,000btu/hr 38,000btu/hr 35,000btu/hr Min Input 19,000btu/hr 26,000btu/hr 22,700but/hr 28,500btu/hr Gas Inlet Pressure Maximum 10.
PLA CEMENT OF LOGS - 18” SETS Front ember log sits under front ember burner tube as shown. Bottom back log is to be placed on back of grate and against burner support brackets as illustrated. Notches in bottom log will go over grate bar . Bottom front log is to be placed on front of grate and against front uprights as illustrated.
PLA CEMENT OF LOGS - 24” & 30” SETS 6 Front ember log sits under front ember burner tube as shown. Bottom back log is to be placed on back of grate and against burner support brackets as illustrated. Notches in bottom log will go over grate bar .
FOR Y OUR SAFETY READ BEFORE LIGHTING W ARNING: If y ou do not f ollow these instructions exactly , a fire or e xplosion ma y result causing proper ty damage, personal injur y or loss of lif e. A. This appliance is equipped with a push-button piezo ignition de vice which automatically lights the pilot.
LIGHTING INSTR UCTIONS “MILLIV OL T V AL VE” 1. ST OP! Read the saf ety inf or mation pre viously listed abov e. 2. Mak e sure manual shutoff v alve is fully open. 3. Set roc ker s witch to OFF position. 4. Press in and tur n control knob clockwise to the OFF position.
TO TURN OFF GAS TO APPLIANCE “MILLIV OL T V AL VE” CONT . SHUTTING OFF HEA TER 1. T ur n control knob cloc kwise to the OFF position. 2. Set roc ker s witch to OFF position Shutting off burner s only (pilot sta ys lit) Y ou ma y shut off burner and keep the pilot lit b y doing one of the f ollowing.
ITEM QU ANTITY DESCRIPTION 1 1 TF-II-18 T OP LEFT LOG 2 1 TF-II-18 T OP RIGHT LOG 3 1 TF-II-18 BO TT OM BACK LOG 4 1 TF-II-18 BO TT OM FRONT LOG 5 1 TF-II-18 FRONT EMBER LOG 6 1 TF-II-24/30 MIDDLE LEF.
TROUBLESHOOTING REFERENCE SYMPT OM POSSIBLE CA USES CORRECTIVE A CTION 1. Pilot will not light with A. Main shutoff valv e closed. 1. Make sure that the shutoff valv e Piezo ignitor located on the pipe supplying gas to the fireplace is open. B. Air in the gas line.
デバイスGolden Blount 18" - 24" & 30"の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Golden Blount 18" - 24" & 30"をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGolden Blount 18" - 24" & 30"の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Golden Blount 18" - 24" & 30"の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Golden Blount 18" - 24" & 30"で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Golden Blount 18" - 24" & 30"を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGolden Blount 18" - 24" & 30"の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Golden Blount 18" - 24" & 30"に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGolden Blount 18" - 24" & 30"デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。