Goodman MfgメーカーASPF Air Handlersの使用説明書/サービス説明書
ページ先へ移動 of 16
© 2007 - 2012 Goodman Manufacturing Compa ny , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com P/N: IO-431 Date: May 2012 ASPF AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
2 Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and com- ply with all safety information and instructions accompanying these symbols.
3 IMPORTANT: To register your Goodman ® brand unit, go to www.goodmanmfg.com and click on “Warranty Registration”. Complete registration as prompted. To register your Amana ® brand unit, go to www.amana- hac.com and click “Warranty Registraion”.
4 Return Ductwork DO NOT TERMINATE THE RETURN DUCTWORK IN AN AREA THAT CAN INTRODUCE TOXIC, OR OBJECTION- ABLE FUMES/ODORS INTO THE DUCTWORK. The return ductwork is to be introduced into the air handler bottom (upflow configuration). Return Air Filters Each installation must include a return air filter.
5 H I G H V O LTA G E ! Fail ure to do so may cause prop ert y dama ge , pe r s o n a l i n ju r y or dea t h . Dis connec t ALL pow er befor e s ervi cing.
6 Low Voltage Connections Several combinations of low voltage schemes are available, depending on the presence of a heat kit and whether the heat kit is single-stage or multi-staging. The low voltage con- nections are determined by whether the outdoor unit is a con- denser or heat pump.
7 Downflow Conversion Conversion to downflow MUST be performed in an area that allows access to all sides prior to placing the air handler in its final location. To prevent the evaporator coil pan from “sweat- ing” the DPI accessory insulation kit is to be used when per- forming this conversion.
8 ASPF Model Insulation Kit 1830 DPI H36-42 3137 / 42 60 DPIH48-6 1 Table 8 The following describes converting to “Horizontal Left-Hand”. Conversion MUST be performed in an area that allows ac- cess to all sides prior to placing the air handler in its final location ( See Figure 6 ).
9 Use of a condensate removal pump is permitted when nec- essary. This condensate pump should have provisions for shutting off the control voltage should a blocked drain occur.
10 ASPF Thermostat Connections NOTES: 1) OUTDOOR THERMOSTAT (OT-1) SHOULD BE THE FIRST TO CLOSE AND THE LAST TO OPEN. 2) JUMPER W1 AND W2 TOGETHER IF OT-2 IS NOT USED.
11 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
12 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH .
13 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
14 THIS P AGE LEFT INTENTIONALL Y BLANK.
15 SPLIT SYSTEMS AIR CONDITIONING AND HEA T PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDA TIONS We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer .
16 © 2007 - 2012 Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE.
デバイスGoodman Mfg ASPF Air Handlersの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Goodman Mfg ASPF Air Handlersをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGoodman Mfg ASPF Air Handlersの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Goodman Mfg ASPF Air Handlersの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Goodman Mfg ASPF Air Handlersで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Goodman Mfg ASPF Air Handlersを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGoodman Mfg ASPF Air Handlersの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Goodman Mfg ASPF Air Handlersに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGoodman Mfg ASPF Air Handlersデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。