• Refer to Service Manual RS6300008 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. • Models listed on page 3.
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit.
PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN GPH13 (M Series) Package Units are designed for outdoor installations only in either residential or light commercial ap- plications and are available in 2, 2.5, 3, 3.5, 4 & 5 ton sizes. They are designed for 208/230 volt single phase applications.
PRODUCT DESIGN 5 Outside Slab Installation -Multi-positional (M) NOTE: Roof overhang should be no more than 36" and provi- sions made to deflect the warm discharge air out from the overhang. Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency.
6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration.
PRODUCT DIMENSIONS 7 GPH13[24-60]M41* MEDIUM CHASSIS GPH1324M41* GPH1330M41* GPH1336M41* GPH1342M41* LARGE CHASSIS GPH1348M41* GPH1360M41* BL OWER ACCES S P ANEL ? ? 2 3 4 51 47 SUP PL Y 1 3/8 A RETUR.
P ACKAGE HEA T PUMP SPECIFICA TIONS 8 GPH13[24-36]M41AB (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes.
P ACKAGE HEA T PUMP SPECIFICA TIONS 9 GPH13[42-60]M41AB (1) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes.
ACCESSORIES 10 GPH13[24-60]M41* Par t N u mb er De scr ipti o n O T 18-60 A O utd oor Th er mosta t Ki t w/L oc k out S tat O T /EHR 18-60 Eme rgenc y Heat R el ay K i t HKR El ec tr ic Heat K i t PG .
BLOWER PERFORMANCE DA T A 11 NOTES: • Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. • Data shown does not include filter pressure drop, approx.
12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P UT B TU/ H R x 10 0 0 BT U OUTPUT vs TEMPER ATU RE RIS E CHART TEMPERAT UR E RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C F M FORMULA S BTU OUTPUT = CFM x 1.
13 COOLING PERFORMANCE DA T A GPH1324M41* MOD E L: GPH 1324M41 * E XP A ND E D P E RFO RM A N CE DA TA C OOL ING OP E R AT IO N Desi g n Su b co o l i ng, 10 + / - 2 ° F @ t h e li q u i d a cce ss fi tt i n g co n n ec tio n A H RI 95 t est co n d i t i o n s.
14 COOLING PERFORMANCE DA T A GPH1324M41* M O DE L : G PH1 3 2 4 M 4 1 * E X P A ND E D P E RFO RM A N CE DA T A C OOL ING OP ER AT IO N De s i gn Subc ooli n g, 1 0 + / -2 °F @ the l i qui d a cc e ss fitting conne c ti on AH RI 95 t e s t c ondi tions.
15 COOLING PERFORMANCE DA T A GPH1330M41* MOD E L: GP H 1330M41* E XP A ND E D PE RF ORM A N CE DA T A C OOL I NG OP E R AT IO N De s i gn Su bc o oli n g, 10 + / -2 °F @ the l i quid a c c ess fi tt ing conn e cti on AH RI 95 t es t c ond i tions .
16 COOLING PERFORMANCE DA T A GPH1330M41* MOD E L : GP H 1330M41* EX PAN DE D P ER FO R M AN C E D AT A C OOLING OP E R AT IO N Desi g n Su b co o l i n g, 10 + / - 2 ° F @ t h e li q u i d a cce ss f i t t i n g co n n ec t io n AH RI 95 t est co n d i t i o n s.
17 COOLING PERFORMANCE DA T A GPH1336M41* MOD E L: GP H 1336M41* EX PAN DE D P E R F O R MANC E D ATA C OOL ING OP ER AT IO N Desi g n Sub co o l i ng, 9 + /-2 °F @ th e l i q u id ac ces s fi tt i n g c o n n ect i o n A H R I 95 t e st co n d i t i ons .
18 COOLING PERFORMANCE DA T A GPH1336M41* M O DE L : G PH1 3 3 6 M4 1 * E X P A ND ED PE RF ORM A N CE DA T A C OOLING OPERAT IO N De s i gn Subc ool i n g, 9 +/ -2 ° F @ the l i qui d ac ce s s fitting c onnec tion A HRI 95 te st c onditi o ns .
19 COOLING PERFORMANCE DA T A GPH1342M41* MOD E L: GP H 1342M41* EX PAN DE D P ER F O R MANC E D ATA CO O L I N G O PE RA T I ON Desi g n Sub co o l i n g , 10 + / - 2 ° F @ t h e li q u i d a cce ss fi t t i n g co n n ec t ion A H RI 95 t est co n d i ti o n s.
20 COOLING PERFORMANCE DA T A GPH1342M41* MOD E L: GP H 1342M41* E XP A ND ED PE RF ORM A N CE DA T A C OOLING OP E R AT IO N Des i g n Su b co o l i n g, 10 + / - 2 ° F @ t h e li q u i d a cce ss f i tt i n g co n n ec t io n A H RI 95 t est co n d i ti o n s.
21 COOLING PERFORMANCE DA T A GPH1348M41* MOD E L: GP H 1348M 41* E X P A ND ED PE RFORM A N CE DA T A C OOL ING OP E R AT IO N D esi g n Su b co o l i n g , 12 + / - 2 ° F @ th e li q u i d a cce ss fi tt i n g co n n ec tio n A H RI 95 t es t co n d i t i o n s .
22 COOLING PERFORMANCE DA T A GPH1348M41* MOD EL: GP H 1348M 41* EX PAN DE D P ER F O R M ANC E D AT A C OOL ING OP E R AT IO N De s i gn Subc ool i n g, 12 +/ -2 °F @ the l i qui d a c c e ss fi tting conne c ti on AH RI 95 t es t c onditi ons.
23 COOLING PERFORMANCE DA T A GPH1360M41* MOD E L: GP H 1360M41* EX PAN DE D P ER F O R MANC E D ATA C OOL ING OP E R AT IO N Des i g n Su b co o l i n g , 9 + /- 2 ° F @ th e l i q u id ac ces s fi tt i ng c o n n ecti o n A H R I 95 t e st co n d i ti o n s .
24 COOLING PERFORMANCE DA T A GPH1360M41* MOD EL: GP H 1360M 41* EX PAN DE D P E R F O R M ANC E D AT A C OOLING OP ER AT IO N D esi g n Su b co o l i n g, 9 + /- 2 ° F @ th e l i q u id ac ces s f i tt i n g c o n n ect i o n A H RI 95 te st co n d i t i on s .
25 HEA TING PERFORMANCE DA T A GPH13[24-42]M41* PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
26 HEA TING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES MA Y BE PRESENT .
28 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES MA Y BE PRESENT .
デバイスGoodman Mfg RT6332013r1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Goodman Mfg RT6332013r1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはGoodman Mfg RT6332013r1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Goodman Mfg RT6332013r1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Goodman Mfg RT6332013r1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Goodman Mfg RT6332013r1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はGoodman Mfg RT6332013r1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Goodman Mfg RT6332013r1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちGoodman Mfg RT6332013r1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。